Door would not close fully on its own
13 of 15 people found this instruction helpful.
  • Stephen from Lutherville, MD
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
I inspected the hinges and found broken cams and door stop on the bottom hinge. I found the parts list for the door and ordered the parts I thought I needed. I found that I did not look at the parts list for the body of the unit and missed a key item and that required me to order another part that made the repair. I should have dug a litt le deeper before I placed my order and it would have been even easier. I was amazed at the speed I received the parts I needed. I ordered the hinge pin mid-morning and the part was on my porch the next afternoon.
Was this helpful?
Thank you for voting!
Existing light switch was hard to remove.
14 of 19 people found this instruction helpful.
  • Stephen from Jupiter, FL
  • A Bit Difficult
  • Less than 15 mins
  • Screw drivers
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this helpful?
Thank you for voting!
support clip broken.
16 of 25 people found this instruction helpful.
  • Arturo from Killeen, TX
  • Easy
  • Less than 15 mins
  • Screw drivers
After figuring out how to remove the old broken clip, replacement was easy. Had to use a small putty knife to open the release on the bottom underside of the clip(between the clip & the refrig) . By looking at the replacement piece it was easy to figure out.
Was this helpful?
Thank you for voting!
Refrigerator Door Wouldn't Close Right
13 of 17 people found this instruction helpful.
  • Anthony from Highland Lakes, NJ
  • Easy
  • 30 - 60 mins
  • Screw drivers, Wrench set
Get 2 "door closing cams" yep. Same as some others here. Found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. Very easy. Bottom bracket has the broken cam riveted to it. Need hacksaw to get this off then punch it through with hammer and a screwdriver. This is the only part that took a little while. Replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half. Replace the closing cam that is on the bottom the the door as well. Even if yours isn't broken. Replace it anyway. Put door back on and done. Not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. Good luck
Was this helpful?
Thank you for voting!
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
16 of 28 people found this instruction helpful.
  • Laura from Manchester, NH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this helpful?
Thank you for voting!
Interior light needed replaced
22 of 46 people found this instruction helpful.
  • Leo from TWIN FALLS, ID
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Was this helpful?
Thank you for voting!
Ice Maker Cap Broke
11 of 14 people found this instruction helpful.
  • TIM from GRETNA, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
It took me about 15 minutes to complete the repair, 1st I emptied the ice maker, then I removed 4 screws from the rear of the ice maker tray and took the plastic piece off of the auger. I reversed the steps and put it back together.
Was this helpful?
Thank you for voting!
Noisy Fan Motor - Bearing went out.
11 of 14 people found this instruction helpful.
  • Robert from Carpinteria, CA
  • Easy
  • 1- 2 hours
  • Nutdriver
Moving the frig out and cleaning was the hardest part of this job - lots of dust collected over the 17 years the frig was in place. Once all the cleaning was done, with the frig out and back cover off (10 -12 screws taken off with nutdriver),I plugged the frig in and observed the the problem was a noisy fan motor. The motor is at the very back of the frig with easy access to the 3 brackets holding it in place.
Pull off the electrical clip. Remove the screw holding the bracket to the frame on the front bracket, leaving the bracket attacked to the fan. The other two screws remove from the fan, leaving the brackets in place.
Reverse the procedure when you receive the new part from PartSelect(great company to deal with)!
Was this helpful?
Thank you for voting!
Switchlight was broken on tennant's refridge
10 of 12 people found this instruction helpful.
  • Mark from Somers Point, NJ
  • Easy
  • Less than 15 mins
  • Pliers, Screw drivers
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapp ed the new switch into place.

10 minutes total.
Was this helpful?
Thank you for voting!
Refrigerator door wouldn't close
9 of 10 people found this instruction helpful.
  • Allen from Paso Robles, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
I weged a block of wood under the door to hold the weight then used a nutdriver to removed the two screws attaching the bottom hinge to the refrigerator. The plastic closing cam was broken and preventing the door from closing. I found some plastic washers in my junk drawer to install on the lower hinge as a temporary fix to keep the appl iance operational until the correct replacement parts could be tracked down. I then called local appliance stores in search of the closing cam and learned that none of them had the part in stock. I then hit the internet and within minutes found a picture of exactly what I needed at PartsSelect.com and had it on order a couple minutes later. A couple days after that, the new hinge was delivered, Again, I proped up the door, removed the lower hinge and replaced it with the new the new one that included the new closing cam. I was very happy to have saved lots of time and money and my wife was even happier to have the refrigerator working properly again. :)
Was this helpful?
Thank you for voting!
Twice I ordered the oven light bulb & each time the light bulb was defected
18 of 38 people found this instruction helpful.
  • Barbara from BELLEVUE, WA
  • Very Difficult
  • Less than 15 mins
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appl iance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Was this helpful?
Thank you for voting!
refrigerator did not cool
10 of 14 people found this instruction helpful.
  • Carl from Kent City, MI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
i put a new evaporator motor in and now it works fine
Was this helpful?
Thank you for voting!
Refridgerator was running constantly and condesor would get very hot, condesor fan would only turn on if I spun it.
8 of 9 people found this instruction helpful.
  • Raymond from Los Lunas, NM
  • Easy
  • 15 - 30 mins
  • Nutdriver, Socket set
Unplugged fridge removed the three screws that held fan on to fan frame unplugged condensor fan removed brackets from old fan and put them on new fan installed new fan plugged in fridge and now it works great!
Was this helpful?
Thank you for voting!
Door Would Not Close Properoy
7 of 7 people found this instruction helpful.
  • Mike from Lake Sherwood, MO
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers, Socket set
Door cam disintegrated after 20 years. This was a terrific site for suggested repairs. My problem was not paying attention to how the door shim, cam and spacer were placed on the hinge. Most of the site's instructions did not forewarn the obvious...pay attention when doing repairs!!

Instructions from others were generally pr etty good but as adept as I am at D-I-Y I still did not pay attention to how I took something apart so it could be assembled properly.

I don't think that ordering an entire door hinge set is necessary. It does not appear that shims and/or spacer come with the hinge assembly. Door cam was all that was needed. I thought about replacing the cam on the freezer side but won't do it until absolutely necessary.

This is a very good website and my thanks to all of the posts for the instructions!!
Was this helpful?
Thank you for voting!
Noisy freezer evaporator fan, bearings worn out
8 of 10 people found this instruction helpful.
  • Todd from Saint Paul, MN
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!