EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details
✖

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

TBX16SAYCRWH General Electric Refrigerator - Instructions

All Instructions for the TBX16SAYCRWH
1 - 15 of 185

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Vegetable pan cover broke down the middle
88 of 91 people found this instruction helpful.
  • Kim from Bronx, NY
  • Really Easy
  • Less than 15 mins
When the cover came to my apartment, I crossed my fingers that the piece would fit . Well, within 5 minutes the old cover was out and the new cover in. And it looks better than new! Finally, I don't have to hold my vegetable drawers up with a D battery!
Was this helpful?
Thank you for voting!
not making ice
33 of 38 people found this instruction helpful.
  • thomas from richmond, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
when the ice maker runs through its cycle, you should be able to hear the solinoid valve open, letting water into the ice maker. this was not happening for me. you can dissconnect the plug on the valve and put the two probes from a multimeter in the plug and set for AC volts. when the ice maker runs its cycle, at the end you should see t he meter jump as power is applied to the valve then turns off. this means you do have power to the valve so the valve is defective. turn off water supply to the valve, disconnect the water supply tube to the valve, remove the screw holding the valve, disconnect supply tube to icemaker then hook up supply tube to bottom of valve, screw braket back to refrig, install suppy back to valve, turn water back on and check for leaks and your ice maker should be working properly again.
these guys were really fast on delivery too!
Was this helpful?
Thank you for voting!
The edge of the vegetable pan cover broke at the edge.
30 of 33 people found this instruction helpful.
  • Lisa from Leesburg, VA
  • Really Easy
  • Less than 15 mins
No tools required! The replacement pan cover was shipped and arrived within 3 days. I pulled out the drawers, then the cover. Slipped the new one in, slipped in the drawers and it was finished.
Was this helpful?
Thank you for voting!
water appearing under refrigerator
31 of 36 people found this instruction helpful.
  • Larry from Dallas, TX
  • Really Easy
  • 1- 2 hours
  • Screw drivers, Wrench set
Unplugged the refrigerator and turned off the water to the ice maker valve. Removed the water line at both ends (small crescent wrench). Removed the cover from the water valve area (two Phillips head screws). Removed the valve (two screws - small nut driver) and pulled off the two electrical connections.

Installed the new valve with the reverse procedure though the holding screws didn't line up with the existing holes in the refrigerator metal frame. I let it go with one screw holding ... didn't have a drill with me to make a second screw hole.

Replaced the old water line (from the wall to the valve) with a steel-reinforced hose.

Cut the female metal connector from the old water line up to the freezer and it fit nicely into the push-in outlet from the new valve. Turned everything back on and waited for the ice maker to cycle.
To my dismay, the leak had been coming from the plastic line that goes from the valve up to the ice maker. It had split, spraying water. Replaced that and everything works fine.

Lesson learned: Don't assume water near the icemaker valve actually is from the valve or its water connections. Watch the whole system cycle a couple of times to see what's really happening. Glad to have a new valve but the basic problem was the icemaker tubing.
Was this helpful?
Thank you for voting!
water valve didn't shut off completly
20 of 24 people found this instruction helpful.
  • Raymond from Concord Twp., OH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set, Wrench (Adjustable)
The valve is not a direct replacement,seems they
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
Was this helpful?
Thank you for voting!
Neeed extra shelves for new purchased refrigerator
22 of 35 people found this instruction helpful.
  • Hollis from Daphne, AL
  • Really Easy
  • Less than 15 mins
Simple install. .
Was this helpful?
Thank you for voting!
Vegetable Pan Cover Cracked
15 of 17 people found this instruction helpful.
  • Rex from Yakima, WA
  • Really Easy
  • Less than 15 mins
Removed 2 vegetable drawers and phone book and cd case supporting the vegetable drawers. Removed food items sitting on top. Lifted out cracked pan cover and put in place the new one. Reinserted all items originally removed except for phone book and cd case. It was a perfect fit and probably the easiest repair job I have ever done. I do not know why I waited 2 years to find the part.
Was this helpful?
Thank you for voting!
Ice maker did not work
15 of 18 people found this instruction helpful.
  • Kenneth from Bellevue, WA
  • Easy
  • 15 - 30 mins
  • Screw drivers, Wrench set
I removed one screw to loosen the cardboard panel that covered the old valve and one screw to remove the valve assembly. I disconnected the two wiring connections and unscrewed the two water line connections. Replacement was really easy since the bracket was the same as the old valve. The down stream water connection was different for the new (push in) than the old (threaded) but I cut the old threaded connector off and figured out that the new push in connection was solid (directions would have really helped here) Reconnected the inlet tubing and electrical wires and replace the panel and it was done.
Was this helpful?
Thank you for voting!
Broken veg. cover/combination shelf
14 of 19 people found this instruction helpful.
  • Gail from Cary, NC
  • Really Easy
  • Less than 15 mins
I purchase a new veg. shelf cover and an additional shelf for my refrigerator. The parts came quickly and I am very happy with the new parts. I have posted your web site on my favorite for future use.
Was this helpful?
Thank you for voting!
Missing Shelf and a broken veggy bin cover
11 of 13 people found this instruction helpful.
  • Lionel from Slidell, LA
  • Really Easy
  • Less than 15 mins
I opened the refrigator door and inserted the shelf where the missing one shoud have went and I remoed the old Vegetable bin cover and replaced it with the new one.-----JOB DONE !
Was this helpful?
Thank you for voting!
Interior light needed replaced
22 of 46 people found this instruction helpful.
  • Leo from TWIN FALLS, ID
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Was this helpful?
Thank you for voting!
Leaking Valve on Ice Maker
10 of 12 people found this instruction helpful.
  • Linda from Montgomery, AL
  • A Bit Difficult
  • 15 - 30 mins
  • Pliers, Screw drivers
I ordered the part and it got here very quickly. Being a novice home repair person, it took me awhile to get the courage to start. It was practically uneventful, but it did take some time to figure it out exactly. I did have to bend the piece some, which is always a little nerve wracking. However, the part is working beautifully and I fee l good about myself.
Was this helpful?
Thank you for voting!
Twice I ordered the oven light bulb & each time the light bulb was defected
18 of 38 people found this instruction helpful.
  • Barbara from BELLEVUE, WA
  • Very Difficult
  • Less than 15 mins
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appl iance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Was this helpful?
Thank you for voting!
Water under refrigerator, leaky ice maker water supply solenoid valve
8 of 8 people found this instruction helpful.
  • Eric from Chicago, IL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
This is a relatively simple repair, but requires a bit of running around your house and sitting in a likely cramped space on the floor behind your refrigerator. These steps assume you have verified the valve is leaking and not the lines. 1. Locate where the water line to the fridge connects to the house plumbing. Close the next valve i n the house plumbing upstream of this connection. Open some fixture (likely the cold on the kitchen sink) to relieve water pressure in this section of plumbing. Water should flow briefly, then dribble and stop on its own. 2. Unplug your fridge. There are moving parts (a fan) close to the valve that may injure you while you are working. 3. Pull your fridge away from the wall enough so you can scoot behind and sit behind. 4. Gather your tools and parts and squeeze behind the fridge. 5. Remove the felt paper dust cover. Carefully collect the screws. 6. Take a picture of the electrical connection to the valve or make a mental note. 7. Carefully unclip lines from the fridge and remove screws holding valve to fridge body. Slicing a line will create a new problem to fix. Carefully collect the screws. 8. Remove electrical connection. Grasp the connector and pull firmly. Do not yank the wires. 9. Over the bucket, disconnect old valve from lines. Some residual water will flow out. If the stream is steady, double check that Step 1 is completed correctly. Set old valve aside. 10. Examine new valve to determine water input and outlet. There may be an arrow indicating flow direction. 11. Seat the input line in the valve input firmly and connect. Mine was a nut I tightened with a small crescent wrench. 12. Seat the outlet line in the valve outlet firmly and connect. Mine was a push in quick connect. 14. Rest the valve over the bucket. Get up and turn the water back on. Verify your connections are not leaking. 15. Review your picture and reconnect the electrical connection. 16. Install the new valve onto the fridge body. Mine was a different geometry that required some gentle bending of the mounting bracket. Reclip lines to fridge. 17. While you're down there, vacuum underneath your fridge. 18. Reinstall felt paper dust cover. 19. Plug fridge back in. Clean up. 20. Monitor your ice maker, verify good operation. When satisfied, push fridge back. Recycle(?) old valve. 21. Success!
Was this helpful?
Thank you for voting!
The old shelf broke in half
8 of 9 people found this instruction helpful.
  • Raymond from Acworth, GA
  • Really Easy
  • Less than 15 mins
I pull the old one out, and put the new one in.
Was this helpful?
Thank you for voting!
All Instructions for the TBX16SAYCRWH
1 - 15 of 185