freezer and refrigerator compartments not cold enough
1 person found this instruction helpful.
  • Michael from Colorado Springs, CO
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
Was this helpful?
Thank you for voting!
compressor not running
1 person found this instruction helpful.
  • Doug from Lancaster, CA
  • Really Easy
  • 15 - 30 mins
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
Was this helpful?
Thank you for voting!
Worked like a charm. Thanks
1 person found this instruction helpful.
  • Keith from Cherryville, NC
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires... Put a thermometer in a glass of water & now runs at 38 degrees.
Was this helpful?
Thank you for voting!
Compressor would not start and run, kept making a clicking noise.
1 person found this instruction helpful.
  • James from St.Johns, FL
  • Really Easy
  • Less than 15 mins
  • Screw drivers
First I unplugged the refrigerator, then removed the lower back panel to get access to the compressor. Then I removed the original compressor start relay, removing the metal clip and unplugged it from the side of the compressor. Installed the new compressor start relay from partselect. Plugged the appliance back in and the refrigerator st arted working again immediately with the compressor running properly and no more clicking sound. Reinstalled lower back panel.
Was this helpful?
Thank you for voting!
No cold
1 person found this instruction helpful.
  • Jacqueline from LEXINGTON PK, MD
  • Very Easy
  • Less than 15 mins
  • Nutdriver, Pliers
Like you video
Was this helpful?
Thank you for voting!
Light rocker switch broke and refrigerator light couldn't go on.
2 of 4 people found this instruction helpful.
  • Cathy from HOPATCONG, NJ
  • Very Easy
  • Less than 15 mins
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
Was this helpful?
Thank you for voting!
Plugged it in.
1 person found this instruction helpful.
  • Adam from GLOVERSVILLE, NY
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
Was this helpful?
Thank you for voting!
Fridge would warm above acceptable levels.
1 person found this instruction helpful.
  • Doug from BRANDON, MS
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Talked to a bud who does this kind of work and he walked me thru the simple job. Also watched a you tube segment. Very easy job. Took off the front kick vent panel. Unscrewed the metal holder and unplugged old part, plugged new part in and put panel back on. Turned on unit and it is working like a charm. Got my fingers crossed just in cas e.
Was this helpful?
Thank you for voting!
Condenser fan making noise
2 of 4 people found this instruction helpful.
  • Richard from North Easton, MA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Wrench set
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easi er to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Was this helpful?
Thank you for voting!
Handle pads were broken
3 of 8 people found this instruction helpful.
  • Daniel from Englewood, CO
  • Easy
  • 15 - 30 mins
  • Screw drivers
Remove the three small screws keeping the old parts on The handle then place the new ones on remembering the position that the old were in replace screws .... that's it !
Was this helpful?
Thank you for voting!
Motor noise while running and clicking when shutting off
1 of 2 people found this instruction helpful.
  • Curtis from Sedona, AZ
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Was this helpful?
Thank you for voting!
Rocker on switch broke off
1 of 2 people found this instruction helpful.
  • David Barnes from ROSWELL, NM
  • Very Easy
  • Less than 15 mins
Eased the putty knife under the edge of the switch housing and pried it off. Pulled two wires off the old terminals and hooked them onto the new one and reinstalled into the refrigerator body.
Was this helpful?
Thank you for voting!
Light switch broke off
1 of 2 people found this instruction helpful.
  • Kathy from TEMECULA, CA
  • Very Easy
  • Less than 15 mins
  • Pliers
We looked up the problem online with the model number of the refrigerator. We ordered the part and followed the video installation that was sent with the order and was found online prior to purchasing
Was this helpful?
Thank you for voting!
refrigerator stopped cooling due to condenser over-heating
1 of 2 people found this instruction helpful.
  • Kevin from COVINGTON, LA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Was this helpful?
Thank you for voting!
Evap Fan Stopped Blowing..
1 of 2 people found this instruction helpful.
  • James from Cave Creek, AZ
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
My fridge / freezer started getting very warm. But, the compressor and condenser fan were operating. I chose the defrost timer from the parts select suggested list. I took it apart and noticed the contacts were in bad shape. I validated this with my dvm meter. By checking continuity across the contacts while turning the timer knob. I also used my meter to check for 115 vac across the 2, 1 connections. . As you turn the timer knob, you'll hear a click. This should close the contacts and connections 4,3 should power up the evap fan. I also pulled the evap fan and powered it up on my test bench. I did this just to validate the timer was the problem. So, if you have a running compressor and condenser fan. Check the contacts on the defrost timer located under the front grill of your unit with a dvm. There is a small gear motor that runs the timer. Don't be fooled by the fact it's running. If the contacts are toast, replace the timer unit. Total time to fix the problem should be 15 mins. Tops.
Was this helpful?