the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
2 of 3 people found this instruction helpful.
  • James C from ARLINGTON, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent openi ng to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
Was this helpful?
Thank you for voting!
Light bulb went out and I was unable to find the right size locally.
2 of 3 people found this instruction helpful.
  • Mary from Lawrenceville, GA
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Had to use a screw driver to remove the cover to replace the bulb. Worked great and your service was great. Probably didn't take more than 5 minutes.
Was this helpful?
Thank you for voting!
Both my microwave halogen lamps went out.
4 of 9 people found this instruction helpful.
  • Vincent from Mount Sinai, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Using a phillips screwdriver I opened the panel in which the two lamps are located and easily removed the lamps. I ordered them through the internet and was pleasantly surprised when I received them the next day.
Was this helpful?
Thank you for voting!
Not heat
1 person found this instruction helpful.
  • Kip from POWELL, OH
  • Very Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Was this helpful?
Thank you for voting!
Burned out magnetron
1 person found this instruction helpful.
  • Dewey from MADISON, AL
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
Removed cover
Disconnected capacitor from old magnetron
Removed old magnetron
Installed new part
Connected capacitor
Reinstalled cover
Was this helpful?
Thank you for voting!
light bulb burned out
1 person found this instruction helpful.
  • David from SAINT LOUIS, MO
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Remove 1 screw, remove light bulb and replace and replace screw. No problem.
Was this helpful?
Thank you for voting!
Door Switch went bad, Internal Fan would run every time you open the door
1 person found this instruction helpful.
  • gilbert from TOMS RIVER, NJ
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
Was this helpful?
Thank you for voting!
Microwave would not heat up
1 person found this instruction helpful.
  • Suzanne from POWELL, OH
  • Really Easy
  • 15 - 30 mins
Part just snapped into place and wires were reattached.
Was this helpful?
Thank you for voting!
M/W would not start. control panel OK
1 person found this instruction helpful.
  • Jeffrey from FULSHEAR, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers
unplugged power
removed main black cover.
located part WB24X10047 and replaced
Was this helpful?
Thank you for voting!
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
1 person found this instruction helpful.
  • Pearlie from Beulaville, NC
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followe d them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
Was this helpful?
Thank you for voting!
The unit would run when the door was open!
1 person found this instruction helpful.
  • Mike from BLUFFTON, SC
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
Was this helpful?
Thank you for voting!
Try to heat food and fuse would blow.
8 of 22 people found this instruction helpful.
  • bart from new sarpy, LA
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
Went on Youtube and pulled up how to fix a microwave.
Was this helpful?
Thank you for voting!
Turntable Stopped Working/Display Timer Would Countdown But Not Heat
1 person found this instruction helpful.
  • Steve from Wesley Chapel, FL
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
With this model, you must remove the outer covering. Don't try to access the display unit from the front like I've seen in some other GE microwave videos. After removing the outer covering, the switches are easy to replace. They are very visible and easy to get to without taking any other parts off. You will see the door switches just behind the display board. Remove the switch and then remove the connecting wires to ensure you don't inadvertently brake a wire. You will need a tamper resistant star bit to remove 3 or 4 screws from the back panel. All other screws are philips head. I went ahead and replaced both switches (yes...there are two of them) and works like a charm. I saved an $800 microwave for less than $60 and know what to do if it happens again. Appears to be a common problem on this model. Thanks for others making a post...It saved me time and money reading others remarks. Good luck!
Was this helpful?
Thank you for voting!
no power in microwave in turn table wouldn't turn light would work act like door was open
5 of 13 people found this instruction helpful.
  • johnny from port orange, FL
  • Easy
  • 1- 2 hours
  • Screw drivers
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
Was this helpful?
Thank you for voting!
To heat a cup of coffee, user entered "10:00" instead of "1:00". Mess! After cleanup, microwave ran, but would not heat. While running, it made 2 or 3 time the noise volume as before.
1 of 2 people found this instruction helpful.
  • G. Wayne from GARDNERVILLE, NV
  • Easy
  • 1- 2 hours
  • Pliers, Screw drivers
I went for the cheap things first. Ohmmeter showed one of the thermostats in the magnetron compartment was open. I ordered and replaced all three thermostats. Still no heat. I took the unit off the wall (aaarrgh!) and checked the oven cavity thermal cutout. It said 7 ohms. I tested by shorting the wires together, but still no heat. So, I ordered the magnetron and diode cable. When replacing the diode cable (be sure to discharge the big cap!) either I broke it, or it was already damaged. It came off in two pieces. The new diode cable was re-enforced with thick heat shrink tubing, to prevent such breaking. You need a very short screwdriver to replace the magnetron. Now, all fixed! ~$150. A new one lists for $2000, installed in the overhead. My wife thinks I am a genius.
Was this helpful?
Thank you for voting!