Models > PSB9240SF6SS > Instructions

PSB9240SF6SS General Electric Microwave - Instructions

All Instructions for the PSB9240SF6SS
31 - 45 of 108
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Light for cooktop burned out
Opened cover, pulled out old bulb, inserted new one, put cover back on. I was out of town when bulbs arived, my wife put it in. She said it was easy.
Parts Used:
Halogen Light Bulb - 120V 20W
  • Bryan from South Beach, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Halogen light for the Microwave above the stove went out.
Ordered the part. 2 days later part arrives. Took me 30 seconds to install the part. Sorry it was not more eventful.
Parts Used:
Halogen Light Bulb - 120V 20W
  • Darren from Madison, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Halogen lamps needed replacement
Easy to repair. One screw, remove bulbs, replace with new ones, secure screw.

Partselect.com shipped items quickly as promised, provided follow up email confirming receipt of order, a second email confirming shipment & a link to check shipping status.

Would not hesitate to do business with Partselect.com again!!!
Parts Used:
Halogen Light Bulb - 120V 20W
  • Don from Wildwood, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lamp burnt out
We had our kitchen remodeled; new cabinets, countertop, range, refigerator, microwave, dishwasher and floor.

The cabinets around the microwave were custom made; it looks great but it hid the screws, which had to be unscrewed to remove the grill so the interior light of the microwave could be replaced.

A stand was used to support the microwave as I lowered it so the screws could exposed so the light could be replaced.

The light was replaced, the microwave was raised back into place and all is well. I replaced the bulb while my wife was out of town. When she returned she noticed that the microwave was nice and clean; she was NOT aware of the fact that the bulb was replaced!

Bob
Racine, WI
Parts Used:
Halogen Light Bulb - 120V 20W
  • Robert L. from Racine, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Both undercabinet light bulbs blown
1. Open the cover over light bulbs with screwdriver.
2. Pulled out blown bulbs.
3. Inserts new bulbs from Partselect.
4. Tested new bulbs
5. Closed the cover over light bulbs with scvrewdriver.
6. Threw out old bulbs and packaging material.

Now, was that easy or what!
Parts Used:
Halogen Light Bulb - 120V 20W
  • pete from roslyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
mICROWAVE WOULD NOT HEAT
I REMOVED THE TOP PANEL OF THE MICR0WAVE AND THEN REMOVED ONE SCREW TO REMOVE THE CONTROL PANEL. rEMOVED OLD SWITCH. SNAPPED IN NEW SWITCH AND CONNECTED WIRE. REPLACED CONTROL PANEL AND UPPER PANEL.
Parts Used:
Primary Door Interlock Switch
  • Peter from Bessemer, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Halogen nite light bulbs had burned out
Parts arrived on the morning of the second day (Saturday) to my pleasant surprise. I opened the nite light access door with a screw driver. Inserted the 2 bulbs without touching the outside of the halogen bulbs. Checked that the bulbs did work and closed the access door. The entire process went quickly and posed very little difficulty.
Parts Used:
Halogen Light Bulb - 120V 20W
  • Thomas from Berwick, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Power
Check with Digital meter all connections.Find a Thermostat open loop.This thermostat is near the Megatron .
Parts Used:
THERMOSTAT
  • Florentino from West Palm Beach, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
6 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven wouldn't sensor reheat & error code on display
I looked at the exploded pic on your web site to find the location of the sensor. Next I removed the cover by unscrewing 15 screws then swaped the sensor and re assembled! Works great! Fixing it my self I saved at least 150$ and did not have to wait all day for a repair man who probaly would not have the part on the first visit.
Parts Used:
Microwave Humidity Sensor
  • Chris from Springfield, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light burned out
removed screw that holds glass for light and replaced bulb.
Reinserted screw that holds glass.

Only down side was cost to ship small bulb.
Parts Used:
Halogen Light Bulb - 120V 20W
  • James from Orient, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Halogen lamps did not light-burned out
Removed the light cover screw with a Phillips screwdriver. Removed the lamps from the packaging just enough to free up the 2 prongs for fitting in the socket. Make sure the power is in the "off position". Install the bulbs one at a time by lining up the 2 sockets (Very important not to touch the halogen bulb glass surface while installing them). Energize the light switch to check operation of the new bulbs.
Parts Used:
Halogen Light Bulb - 120V 20W
  • dennis from harbor springs, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
runs but does not heat
I removed the main cover ( torx security bit required) and tested the magnetron, capacitor, diode and door interlock switches according to instructions found on the internet. The capacitor and diode tested good but the magnetron looked burnt and corroded on the tip. The magnetron I received was an exact replacement for the original. It was easy to replace the magnetron which arrived in 2 days standard shipping. I also cleaned the fan while I had access to the inside area. Hoping to get another 18 years use from the microwave!
Parts Used:
Microwave Magnetron
  • Scott from PIEDMONT, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frost build up on bottom to ice bin and delivery chute in door creating ice blockage
Remove the ice bin.
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of the freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Parts Used:
FUSE
  • Ronald from PONCA CITY, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent opening to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
Parts Used:
Oven Cavity Temperature Cut-Out
  • James C from ARLINGTON, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad door switch and divide
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry up. Removing grnd wires helps
Parts Used:
Diode Cable SWITCH MONITOR INTERLOCK Primary Door Interlock Switch
  • Robert from COLORADO SPGS, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PSB9240SF6SS