Burned out light in microwave
Spouse just screwed in the new bulb and reinstalled the light cover plate with the two screws. Took under a minute. Works great.
Parts Used:
Light Bulb - 40W
  • DANNY from SAINT JOHNS, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave losing heating items
Took microwave out of builtin cabinet with 4 screws.
Put microwave on center island and removed cover.
Tested interlock switch with volt meter and it appeared ok so I put my kit back in box and sent back.
Took out magnetron unit and replace with new part.
Put cover back on and test.
All is working and installed back in cabinet. Two weeks later all still working great.
Parts Used:
Microwave Magnetron Door Interlock Switch Kit
  • John from PEORIA, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Items were not getting heated up in the microwave,
I went to LG website enter model number and was given a list of parts that need to be replaced with a percentage of which part fails the most. I order micro switch PS3522738 which arrived and PS3529293 was backordered. I installed the one that arrived. The microwave worked briefly. I reordered and waited for both switches to arrive and installed both. The microwave still doesn't work.
Parts Used:
Micro Switch
  • Kenneth from CRYSTAL LAKE, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Tray got chipped on the corner
ordered a new tray
Parts Used:
Microwave Glass Cooking Tray
  • Mary Lee from LK FOREST PK, WA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burned out bulb
Husband replaced the bulb
Parts Used:
Light Bulb - 40W
  • Theresa from OVERLAND PARK, KS
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Micro Wave no heat all else fine. Also at times door would not shut properly.
Replace (after testing w/ohm meter) diode and locker holder. My door often would not close properly. Microwave let know by saying not shut properly. When disassembled found the top screw mount was hollowed out resulting in it moving on occasion when you close door. First remove casing (special safety torx head) needed for rear screws. Onc e removed all parts available to view or work on. Diode is on the capacitor so caution is needed when removing. Serious shock hazard if touched. Use insulated pliers to remove from capacitor and a phillips on the ground. Test with ohm meter Should have resistance on way and non the opposite. Replaced mine bad. Next the holder 2 phillips screws and its yours. Unplug each switch and remove. Take note to what wires go to what switch and what switch mounts where. Mine had 3 switches. Removed from old holder and put in new. Screwed holder back in place and left scrws loose till re wired. Once wired set the holder by lightly tighting the screws. Try the door till it seats properly ensuring that all 3 switches are working properly. If so thighten screws. If all seems to work as advertised, safely plug in and test unit if heats up un plug and put cover back on micro. Your all set. Happy heating.
Parts Used:
HOLDER,LOCKER
  • Roy from MILLINGTON, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Power Went Completely Out
The power on the microwave went completely out when I went to use it, but there was no power failure for the house or neighborhood. We removed the microwave from above the oven. Took out the screws on the sides and back of the microwave and slid the top back. The line fuse was located on top unobstructed, NOT behind the button panel like some microwave models. As the appliance is over 20 years old the line fuse was quite old. It was really hard to pry it out of its holder and actually broke. I used a vacuum to suck up the dust and glass and it was easier to get out the ends once the middle broke. Popped the new line fuse in, slid the top back on, put in the screws and put the microwave back in its compartment above the stove. Good as new!! We were about to spend money on a new microwave, but thankfully I came across this site. So happy I did!!

This repair was really easy. The part that took the most time was taking it down from it's compartment above the oven and putting it back up there once repaired.
Parts Used:
Microwave Line Fuse
  • Brittney from LUFKIN, TX
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replacement of hood light bulbs
Unplug the microwave. Then remove the six screws that hold the lower panel which has the light bulb cover and a couple of vent filters. The light bulb sockets are on a fixture that is connected by a quick connect electrical connector. Disconnect that and the whole panel is free to access the bulbs. My bulbs were very fragile and trying to twist them out resulted in the glass twisitng loose with the base still in the sockets. I needed to use a needle nose pliers to remove the bases and then I replaced the bulbs and put every thing back together
Parts Used:
Light Bulb - 40W
  • Jerry from Pine, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven would not start when closing door.
Removed some cosmetic panels. Removed the assembly with micro switches. Examined the faulty switch by checking the clicking action of switch. Two others were ok by this method. Replaced the switch with new one. Works fine so far. Thanks to web site and YouTube videos.
Parts Used:
Micro Switch
  • Raymond from DEPEW, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy and turning plate would not turn
Pulled unit out, pried the bottom plate off the unit. Mine was not screwed in, but designed to be pried off, and then replaced. That was a surprise, but not very difficult. Unscrewed the motor, unplugged the electric connection, replaced it with new part . Replaced the bottom plate and tested the machine.
Parts Used:
Turntable Motor
  • Donna from ARLINGTON, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No heat when the microwave was in use
The instructions on the website were incredibly easy and I saved myself a lot of headache by using this site.

-it was built in unit - so I needed to pull the decorative grill from around the outside to remove it from the wall
- removing the back of the case involved removing phillips head screws from along the side and back of the unit. the only issue I encountered on removing screws was the fact that the "torx / star" screws could not be fit with the wrench that I had (they had a pin in the center that would not allow the wrench to fit into the star). However, a pair of pliers was handy and they were removed just easily.
- I had ordered both the high voltage diode and magnetron because I didn't know which item was the problem. I grounded the diode with two screwdrivers while wearing rubber gloves to be safe. the warnings on this did the trick as it was the only scary part of the operation.
- the diode was a little hard to spot looking at the schematics, but is is found on the lower right corner of the right side of the panel and easily pulled out and replaced. I tried the microwave again to see if it worked...and it did not. So I confirmed that the magnetron was the issue.
- removing the screws for the magnetron and putting in the replacement was a dead easy and I tried the microwave again before putting cover back on. Worked like a charm. Super easy!
Parts Used:
Microwave Magnetron
  • Stuart from STUART, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave Had all functions , no heat
Had to remove unit from above stove, this step will take the longest. With unit on table cushioned with a throw rug under it . I removed the case and located the magnetron removed 3 screws, unplugged unit with a needle nose pliers, installed new unit plugged it in and checked the microwave with a cold coffee cup of water . Worked great! Heated great!
Parts Used:
Microwave Magnetron
  • Clifford from YORK, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not start
Watched a you tube video prior to installing new switch. Followed the video which gave me confidence i was up to the task. After removing the touch pad I found my design was not exactly like the you tube model but I found the defective switch, replaced it and put the microwave back together. Works great. Again watch the videos
Parts Used:
Door Interlock Switch Kit
  • LENNARD from BURNSVILLE, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No problem
I had a son put in the new light bulbs. Rather simple
Parts Used:
Light Bulb - 120V 25W
  • Janet from PITTSFORD, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door switch malfunction
Take cover off microwave. Check door switches to determine which one was faulty.Remove and replace faulty switch.
Parts Used:
Micro Switch
  • Sherry from PINELAND, SC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the MHE14XKB