Freezer Cold With Ice Forming, Fresh Food Warm...Replacing Heater Elements.
3 of 4 people
found this instruction helpful.
-
Rick from Livonia, NY
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers
1. Removed food from freezer and unplug refrigerator or shut circuit breaker. 2. Removed freezer shelves 3. Unscrew all screws on inside back wall and removed back wall plate. Run a fan to defrost the coils. 4. Unscrewed 4 heater bracket nuts on front of cooling coils and removed heater elements. Mine were burnt so I knew I had t
... Read more
he correct part. 5. Removed the heater wires from back panel. 6. Install new heater elements being careful not to leave oils from hands on glass tubes and connected 2 wires from heating elements to rear panel. Reinstall nuts to hold heater brackets. 7. Plug in and run refrigerator for 2 hours with doors closed. Remove upper rear panel on fresh food side then use a flat head screwdriver to turn red timer screw above refrigerator thermostat clockwise slowly until compressor shuts down. 8. Open freezer and waited a few minutes to watch defrost heater coils glow. If they don't glow you might need a new thermostat for the freezer which is located on rear panel or a new timer. 9. Unplug and reinstall rear panel and shelves. Plug in. It will take 24 to 48hrs. For temperatures to level out. Good luck.
Read less
Was this helpful?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
3 of 4 people
found this instruction helpful.
-
David from Hemet, CA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull t
... Read more
he connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Read less
Was this helpful?
Thank you for voting!
changed the light bulb still would not work so I figured it was the switch sure enough.
3 of 4 people
found this instruction helpful.
-
anthony from HAVELOCK, NC
- Really Easy
- 15 - 30 mins
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this helpful?
Thank you for voting!
defective light switch
3 of 4 people
found this instruction helpful.
-
THOMAS from WILLARD, OH
- Really Easy
- Less than 15 mins
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Was this helpful?
Thank you for voting!
Door light switch disintegrated
2 of 2 people
found this instruction helpful.
-
Thomas from Roseville, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
Very simple fix, remove 3 screws, two connectors to the old switch
Was this helpful?
Thank you for voting!
lights did not work
2 of 2 people
found this instruction helpful.
-
Daniel from rochester hils, MI
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
pulled out old socket and replaced supposed to be a duel socket but no longer exists
Was this helpful?
Thank you for voting!
Light didnt go on
3 of 5 people
found this instruction helpful.
-
dorotea from staten island, NY
- Really Easy
- Less than 15 mins
-
Screw drivers
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
Was this helpful?
Thank you for voting!
fridge door switch did not work
2 of 2 people
found this instruction helpful.
-
stu from richmond, VA
- Easy
- Less than 15 mins
-
Socket set
I removed the switch housing (4 screws), replacing the switch in the housing was a snap. It took 5 minutes, cost $8 and light works like new!
Why didn't I order this part and do the repair earlier? Very simple.
Why didn't I order this part and do the repair earlier? Very simple.
Was this helpful?
Thank you for voting!
Refrigerator compartment warming up
3 of 5 people
found this instruction helpful.
-
CHRIS from BAYTOWN, TX
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
The can drinks in refrigerator were not as cold as usual. I opened the freezer and touched the back panel and noticed there was a frost buildup. Since I have had this problem before, I knew that the defrost heater must be bad. I removed all the shelves and the tracks. The back panel is held in by 8 small sheet metal screws. I removed the
... Read more
screws and pulled the back panel up and out. The refrigerator is in garage, so I put a fan in front of it and the fan melted the ice off the coils. I disconnected the wires and checked the the heaters (both wired together) with an ohm meter. The meter showed the heaters to be open. (bad). Actually only 1 of the 2 heaters were bad, but I replaced both of them since they are wired together as a set.
Read less
Was this helpful?
Thank you for voting!
ice accumulating on evaporator of freezer.
2 of 2 people
found this instruction helpful.
-
rolando from round lake beach, IL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Removed ice maker bin,removed screws on back panel cover. Pulled out panel cover,thawed accumulated ice, unscrewed bracket holding defrost heater set, unplugged busted defroster, plugged in new defroster set,installed it back, installed back panel cover, ice maker and powered it on.More than a week after installation,I don't see any signs
... Read more
of ice accumulation on back panel cover.
Read less
Was this helpful?
Thank you for voting!
defrost heater burn out
2 of 2 people
found this instruction helpful.
-
Jerry from Cleveland, NC
- A Bit Difficult
- 30 - 60 mins
-
Pliers, Screw drivers
Frist pulled everything out of freezer put in refridge then took out ice maker box then removed ice maker motor removed back panel took hair drier defrosted the coil then removed bracket screws that hold heaters in place removed bad heater, the hardest part of the job was getting the wirers back around the coils when done just reversed t
... Read more
he process.I have a side by side so there was not a whole lot of room to work with. I only weigh 160 lbs it was a tight fit for me. But all in all it went well.
Thanks
Thanks
Read less
Was this helpful?
Thank you for voting!
Refrigerator and freezer compartment gradually get warmer, frost buildup on back of freezer compartment.
3 of 5 people
found this instruction helpful.
-
Bruce from Rock Rapids, IA
- Easy
- More than 2 hours
-
Nutdriver, Screw drivers
Remove freezer contents, shelving, baskets, shelf brackets, basket rails. Then, remove the icemaker including the ice basket, the cube freezer and the motor assembly. Remove the back liner of the freezer compartment. Remove and replace the defrost heater assembly, using the old mounting brackets and connecting the wires to the same ter
... Read more
minals. Reassemble. Discard excess screws :).
Read less
Was this helpful?
Thank you for voting!
Freezer-side cold; Fridge-side warm of side-by-side Refridgerator
2 of 3 people
found this instruction helpful.
-
Cami from Carmel, IN
- A Bit Difficult
- More than 2 hours
-
Screw drivers
evaporator coils were frozen solid and air wasn't flowing across them
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer s ... Read more ide is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer s ... Read more ide is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
Read less
Was this helpful?
Thank you for voting!
Replaced refrigerator light assbly
2 of 3 people
found this instruction helpful.
-
Charles from Stone Mountain, GA
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
replacement was relative easy. The problem came with wire connector that had to be cut, stripped and crimped. The crimping was the dificult part. the connector was a problem to crimp.
Was this helpful?
Thank you for voting!
freezer (later fridge too) wouldn't stay cold~
2 of 3 people
found this instruction helpful.
-
David from MARYLAND HTS, MO
- Very Easy
- 30 - 60 mins
-
Nutdriver
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and acce
... Read more
ss panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
Read less
Was this helpful?
Thank you for voting!