My gas dryer was drying intermittantly. The gas valve wasn't opening when the igniter was firing up.
1 person found this instruction helpful.
  • Alfred from DELMAR, DE
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
rts came quickly & I got started. First, I unplugged the dryer and pulled it away from the wall about a foot. this was done so the top would have clearance when it was lifted up. Next, I removed the lint trap and then took the two screws under the lint trap door out. Then you use a screwdriver(flat blade) to release the top of the dryer. The release points are about 1-2 inches from the edge of dryer. Next pull the wire connector apart so the front can be removed. The connector is on the right side, front corner, facing the dryer. There are two hexhead screws near the top on both sides. Remove the and the front will come apart as you lift it slightly. Then you disengage the tub belt. Once this is done the tub can be lifted out and set aside/ take care to remember each things position as you take it apart, so you will not get confused when you reassemble. Now the solinoid assembley is easy to get to. Use a phillips screw driver and remove the two screws that retain the bracket that holds the solinoids in place.. Lift the bracket and remove one solinoid at a time. Pull the wire from it and plug the new, like solinoid to the wire and put it back in place. then do the other one. set the bracket back over the new kit and replace the screws to the bracket. Set the tub back in, rethread the belt to the drive wheel. Next put the front back on making sure the bottom part slips into the two sides of the dryer.Replace the hexhead screws on each side; plug the wire connector together. Now , pull the lid down into position and press into place. Replace the lint trap screws and replace the lint trap. Plug dryer up and we are done. Repossition the dryer to its original place. It really was not a hard job at all. Thank-you Susan for your help and expertise.
Was this helpful?
Thank you for voting!
Dryer would not heat
1 person found this instruction helpful.
  • Michael from STOW, OH
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Followed directions from Youtube video
Was this helpful?
Thank you for voting!
Dryer not getting hot
1 person found this instruction helpful.
  • jeff from SPARTA, NJ
  • Very Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Open top of dryer, then remove front. Coils on lower left. Unplug and replace coils. Vacuum loose lint from bottom of dryer. Replace front then top of dryer. Test run. All good !
Was this helpful?
Thank you for voting!
dryer not heating( after replacing the high temp. thermostat
2 of 4 people found this instruction helpful.
  • james from HURON, OH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
i removed the door and front panel then removed the two screws holding the coil bracket,disconnected the two wires on coils,set new coils in place and reversed the above process
Was this helpful?
Thank you for voting!
no flame on burner after initial ignite
2 of 4 people found this instruction helpful.
  • Thomas from Muskegon, MI
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
I shut off the power supply (pulled plug) . Opened the front access door on bottom of dryer, The two coils sat on top of burner unit, with a plate and 2 Phillip head screws securing them. .I used a small set of pliers to pull the terminals off, then I used a short Phillip head screw driver due to the proximity of the dryer drum close by. The coils slide off, slide the new ones on, re secure the plate with screws, reconnect the terminals, plug in the power cord and away you are for a fraction of the cost.
Was this helpful?
Thank you for voting!
The gas would not ignite.
2 of 4 people found this instruction helpful.
  • Leslie from Idaho Falls, ID
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
First we removed the front panel then the door. Removed the old coils and put in the new coils, oh yeah don't forget to disconnect the power supply first. Sure enough that was all it took and it runs great. You really can fix your own appliance if you take the time to do some research.
Was this helpful?
Thank you for voting!
Dryer would light for 30 secs. & flame would go out
2 of 4 people found this instruction helpful.
  • Gary from Springfiled, OH
  • Easy
  • Less than 15 mins
  • Screw drivers
Checked ignitor it was working ok, disconnected 3 pronged coil and disconnected 2 pronged coil using multi tester checked continuity on both coils both tested 0,with help of operator ordered M Series new style coil kit. When parts arrived installed coils attached wire harnesses installed bracket and 2 screws that secures coils. Started dr yer it worked and stayed working who needs the Maytag Repair Man probably saved about 200.00 between service call and markup on coils. Thanks Virtual Repairman
Was this helpful?
Thank you for voting!
No Heat from dyer
1 person found this instruction helpful.
  • Jeff from Livermore, CA
  • Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
Well, this is quite easy really. I found the problem after plucking and chucking a few parts but it was finally the igniter that was the problem. After taking the front section panel off to access the components, take the time to unscrew the igniter and see if it is cracked. That is what happened to my unit. I replaced to the new M series coils as well but the issue was the igniter. Look very carefully for a crack, the one on my unit was very small. You can ohm it out with a meter and if it reads open it is cracked.
Was this helpful?
Thank you for voting!
Dryer flame would light then would not ignite again
1 person found this instruction helpful.
  • Susan from Glendale, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers, Socket set
I used a socket to take of the front cover. I used a screwdriver to remove the two screws that held the coils in place. Replaced the coils and put everything backs together. Piece of cake!
Was this helpful?
Thank you for voting!
Gas dryer would not ignite.
1 person found this instruction helpful.
  • William from Plainfield, IN
  • Really Easy
  • Less than 15 mins
  • Nutdriver
I removed two wires from the coil valves. Then I removed two screws from the bracket that holds the coil valves in place. I removed the faulty coil valves and replaced them with the new ones. Put the bracket back on and replaced the two screws and wires. It took almost 5 minutes. The dryer is like new once again.
Was this helpful?
Thank you for voting!
igniter wold come on for a second then shut off no flame
2 of 4 people found this instruction helpful.
  • shaun from mount laurel, NJ
  • Really Easy
  • Less than 15 mins
  • Socket set
removed the two screws that hold the coils in place pulled the coils terminal connections off removed and replaced with new coils reattached quick disconnect terminals dryer now works better than when it was new
Was this helpful?
Thank you for voting!
Igniter works, valves open, gas Ignitestation then shuts off
1 person found this instruction helpful.
  • Jon from RIVERSIDE, CA
  • Very Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
All the videos said the same thing. If the Igniter works and the gas ignites bit shuts off soon after that, then the coils are bad. I bought the coils and it didn't fix the problem. My bad, I should have put my meter on it to test it before I bought the part and waited a week to get the coils. Now I'm in the process of illuminating the sensors. I will figure it out. Make sure you use the meter. It will save you the headaches.
Was this helpful?
Thank you for voting!
clothes were not drying in expected timeframe
1 person found this instruction helpful.
  • Robert from WARWICK, RI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Socket set
1st replaced limit thermostat because it tested bad; this did not resolve the problem. Initial burn was successful. Heating element would heat but burner would not ignite for subsequent burns unless allowed to cool down for 10 minutes or more. Coils tested at correct values, but a u-tube video said that was not always an indication of a flawless coil set. It was either the coils or the burner itself. Burner would not have been a justifiable expense even though it came with new coil set, so tried the coil set, and it resolved the problem.
Was this helpful?
Thank you for voting!
dryer was not heating
1 person found this instruction helpful.
  • marlon from KINGMAN, IN
  • Easy
  • 15 - 30 mins
  • Screw drivers
popped top up with flat screw-took out 4 screws (2 screws-1/4" nut driver - 2 phillips screws on bracket that holds coils in place) unplugged 2 wire lugs (1 three wire & 1 two wire) changed out bad coils screws back in-plugged wires back in -popped top back down .done
Was this helpful?
Thank you for voting!
Flame wouldn't ignite.
1 person found this instruction helpful.
  • Bryan from YORK, PA
  • Really Easy
  • 15 - 30 mins
  • Socket set
I watched a video. The man speaking was Wayne from parts direct. He made the repair go so smoothly. I enjoyed watching him and I hope you include him in more videos. Had dryer apart and back together (after I had to take top back off, to re-attach the door switch, which I forgot. Had a senior moment!!) in 15 min.And working as good as new . Thank you Wayne. Have a nice day. Bryan