This microwave door switch provides power to the various components in the microwave when the door is in a closed position, and interrupts power when the door is open. This door switch is approximately 1 1/2 inches long, and has 2 metal prongs called terminals that extend from its body. If your microwave will not turn or heat properly, th...Read moreere could be an issue with the door switch. You can check the switch for continuity using a multi-meter. With the actuator button depressed, you should see continuity between these terminals. If there is no continuity the switch will need to be replaced.
NOTE: Before you begin this repair, first make sure your microwave is unplugged, and that your capacitor is discharged. A capacitor stores large amounts of electricity even when your microwave is unplugged.
This micro-switch is designed for use in your microwave. The function of this part is to monitor the door latch position and communicate to the electronic control board whether the latch is open or closed. If your microwave does not provide heat, or will not start properly, you may need to replace the micro-switch. This part is approximat...Read moreely 1 inch in length and 3/4-inch in width. It is made of black plastic with two metal prongs. This is an OEM part sourced directly from the manufacturer. This part is sold individually. Be sure to disconnect the microwave from the power source before you begin this repair.
This is a heat-resistant adhesive for your appliance. The heat resistance allows you to stick parts such as grate feet, gaskets, and felt seals in hot areas, such as a cooktop, without compromising the integrity of the adhesive. It is white in color, and the tube is approximately 7.5 inches long.
The fuse-time delay may also be known as a line fuse or a microwave fuse, and it is a piece for your microwave. The function of this part is to shut off the microwave if there is a power surge, in order to protect your microwave from damage. You should consider having a service technician install this part as the high-voltage capacitors i...Read moren a microwave can contain a very harmful electrical charge, even when the microwave is unplugged and has been inactive for some time. The tools that would be needed to complete this installation include a Phillips screwdriver, an insulated screwdriver, and a pair of pliers.
This part is a genuine manufacturer door interlock switch kit, also known as primary micro switch or microwave switch kit, for a microwave. The function of this part is to sense when the door of the microwave is open or closed. If the part is defective, the microwave will not start or will start when door is open. This kit contains two 15...Read more Amp, 125/250 Volt switches with 3/16 inch terminals. Be sure to disconnect power to microwave before replacing part. Use extreme caution when replacing microwave parts, as high-voltage capacitors can retain an electrical charge when unplugged. NOTE: This kit includes 2 single pole, double throw (SPDT) micro switches. As per the manufacture for the secondary interlock switch order part # 56001100.
This roller is located underneath the glass turntable. With the help of the motor, this roller helps to rotate the glass tray. This part takes the place of the coupling.
See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!View More
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Microwave worked intermittently depending on how door was closed
67 of 85 peoplefound this instruction helpful.
Robert from Bainbridge Island, WA
A Bit Difficult
30 - 60 mins
Pliers, Screw drivers
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and a
... Read morelso took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
Read less
Was this helpful?
Thank you for voting!
loud buzzing noise
56 of 100 peoplefound this instruction helpful.
Sandra from coto de caza, CA
Really Easy
15 - 30 mins
Screw drivers
The repair went well...I am so glad that I read this info before buying a new microwave....it saved me lots of money. I did have a repair man come and look at it and he told me to buy a new one but it cost alot of money when it wasn't necessary. I did the repair and I was very proud of myself. Three men watched a woman fix this and
... Read moreit was no problem...they were impressed also....
Read less
Was this helpful?
Thank you for voting!
Broken door micro switch. (unit does not start heating)
37 of 68 peoplefound this instruction helpful.
JAMES from BILLINGS, MT
Very Easy
30 - 60 mins
Screw drivers
Unplug the unit before servicing. Need phillips screwdriver. Open door. Use step ladder to access and remove 2 small screws from top of the room air diffuser at top of unit. Slide diffuser slightly to the left to align the diffuser's plastic tab on the left side to rotate toward you. (The wires for the front control panel are at the far l
... Read moreeft side of this difuser, but difuser is slotted for easy removal). Once the difuser is removed you will see 1 screw at the top that secures the pannel cover on the left side of the unit. Remove screw and slide this panel slightly up and out. This exposes the plastic frame that holds the upper and lower door switches. To locate the door switches and observe how they work, close and open the door and watch the door (bayonets) open and close the micro switches. Do the (red) buttons on top of the switches move up and down when the door bayonets push and release? If the buttons do not "pop" up when opened the switch is defective. The switch frame is secured with 2 screws. Remove screws and rotate the unit out for easy access to the micro switch(s). The internal (spring?) on my unit that is suposed to allow the red (visible) button on top of the switch to "pop" up when the door is opened was broken. Carefully pry the switch outward while being careful to lift the plastic holder-piece that holds the switch in place. Be careful, there is a small pin on the frame, so rotate the switch OUT toward you while lifting (carefully) the plastic holder-piece (you will see it on top of the switch). You can use an ohm meter to test the continuity of the switches. But if the buttons don't "pop" they are defective. Replace switch and reassemble.