frezer not staying cold enough to freze newly added product
13 of 18 people
found this instruction helpful.
-
Robert H. from Grand Blanc, MI
- Really Easy
- 15 - 30 mins
-
Screw drivers
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part.
... Read more
Thank you
Read less
Was this helpful?
Thank you for voting!
Freezer quit. Compressor would not start.
9 of 11 people
found this instruction helpful.
-
Steve from Neosho, MO
- Really Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Like another post, the start relay rattled like a baby rattle. Replaced the start relay and freezer works great.
Was this helpful?
Thank you for voting!
mottor starts than stop.
9 of 11 people
found this instruction helpful.
-
Gilmar from Miami, FL
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set
i looked byhind the freezer , the mottor has the relay connected to it.i took out the relay, and i descovery something was loose inside, i decided to take to check out at sears to see if they have in stock that especific relay. they did not have, they could order, that's when i dicided to go ahead and looking for in the internet, good i f
... Read more
ound PARTSELECT,they had the part and i was very nice attended,they sent in 2 days i had fix my freezer. thanks PARTSELECT. gilmar couto.
Read less
Was this helpful?
Thank you for voting!
Freezer and refrigerator stopped cooling
8 of 8 people
found this instruction helpful.
-
Amy from PITTSBURGH, PA
- Easy
- Less than 15 mins
-
Screw drivers
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
Was this helpful?
Thank you for voting!
Freezer not defrosting
8 of 9 people
found this instruction helpful.
-
Tom from Argyle, WI
- Really Easy
- 15 - 30 mins
-
Nutdriver
Replaced defrost thermostat and defrost timer on my commercial Kelvinator freezer. Took out screws inside freezer compartment that hold panel at top inside freezer.Once the screws were removed I pulled out the thermostat dial so the panel was free to drop down and expose coils to the freezer that were located in the top rear of the inside
... Read more
freezer compartment.The defrost thermostat was located on the top of the coil to the top left as you face the inside of the Kelvinator KFS220RHY1 freezer. Very easy unplug old and plug in new defrost thermostat. Also replaced timer located in the back side of the freezer down near the middle of the bottom of the freezer near the compressor. There were two nuts holding the timer in the back of the freezer once I took those out I just unplugged the old timer and plugged the new timer in ....very simple fix. I have only run my freezer for a week since I replaced both parts but so far all is working well.
Read less
Was this helpful?
Thank you for voting!
defrost thermostat was open most of the time and didn't let the defrost element heat up.
9 of 13 people
found this instruction helpful.
-
Elvin from Gardner, KS
- Easy
- 15 - 30 mins
-
Nutdriver
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
Was this helpful?
Thank you for voting!
Freezer was freezing solid
6 of 7 people
found this instruction helpful.
-
Matt from Cincinnati, OH
- Easy
- Less than 15 mins
-
Pliers
I first replaced the defrost timer about a week prior and it did not correct the problem. I then ordered the thermostat from partselect and within 15 minutes had the part installed. My refridgerator has been running correctly for a couple weeks.
Was this helpful?
Thank you for voting!
The freezer was not keeping food frozen
6 of 7 people
found this instruction helpful.
-
Jeffry from VERONA, WI
- Easy
- 1- 2 hours
-
Screw drivers
I replaced the timer and the defrost thermostat. The defrost thermostat replacement was almost exactly like the training video here. The old part attached slightly differently. The most time consuming part was thawing out the heat exchanger, which was completely covered with ice, inside and out.
Compared to the training video, ... Read more the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Compared to the training video, ... Read more the timer took more work given its location. It was low to the ground and a bit difficult to get at around the other wires and parts. However, the new part fit perfectly. I just unplugged and unscrewed the old part then reversed those steps with the new one.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Refigerator Not Staying Cold
5 of 5 people
found this instruction helpful.
-
Marsha from BEVERLY, MA
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers, Wrench set
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely
... Read more
does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Read less
Was this helpful?
Thank you for voting!
Freezer was running too warm
6 of 8 people
found this instruction helpful.
-
Jeanne from SAN ANTONIO, TX
- Very Easy
- Less than 15 mins
-
Screw drivers
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Was this helpful?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
5 of 5 people
found this instruction helpful.
-
Bruce from MARTINEZ, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to ... Read more uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Read less
Was this helpful?
Thank you for voting!
Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
4 of 4 people
found this instruction helpful.
-
David from ABINGDON, VA
- Easy
- 15 - 30 mins
-
Screw drivers
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the cop
... Read more
per refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
Read less
Was this helpful?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people
found this instruction helpful.
-
gary from ARANSAS PASS, TX
- Easy
- 30 - 60 mins
-
Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Read less
Was this helpful?
Thank you for voting!
Compressor keep running would not cool.frozen coil
4 of 5 people
found this instruction helpful.
-
Mark from SEYMOUR, TN
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
As per instructions.removed inside shelves.removed back cover over coil let thaw.removed old thermostat &clips as per instructions.replaced with new.
Was this helpful?
Thank you for voting!
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
3 of 3 people
found this instruction helpful.
-
Tunis from NOLANVILLE, TX
- Easy
- 15 - 30 mins
-
Screw drivers
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
Was this helpful?
Thank you for voting!