EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details
✖

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

E23CS75DSSH Electrolux Refrigerator - Instructions

All Instructions for the E23CS75DSSH
106 - 120 of 581

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Replace ice maker which was splashing water
5 of 5 people found this instruction helpful.
  • John from PHOENIX, AZ
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Wrench set
Turn off ice maker
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Was this helpful?
Thank you for voting!
The icemaker would not make ice because I removed the filter
6 of 8 people found this instruction helpful.
  • CHARLES from FRACKVILLE, PA
  • Really Easy
  • Less than 15 mins
I removed the filter bypass from the box. I opened the refrigerator door. I put the filter bypass in the space where the filter was located. I closed the refrigerator door. I opened the freezer door. I turned on the ice maker. It worked.
Was this helpful?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
5 of 5 people found this instruction helpful.
  • Bruce from MARTINEZ, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.

After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.

I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.

I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Was this helpful?
Thank you for voting!
Meat Pan Cover Broke
5 of 5 people found this instruction helpful.
  • William from FOREST HILL, LA
  • Really Easy
  • Less than 15 mins
Popped out glass, pulled up and the front of cover and pulled froward. Pushed new cover back on to studs and pushed down on cover to lock it to front studs. Put glass on top of new cover. About 3 min total to make repair.
Was this helpful?
Thank you for voting!
broken shelf support
5 of 6 people found this instruction helpful.
  • Richard from West Seneca, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I broke off remainder of clip, and used phillip
screwdriver and pushed pin into wall. I lined up new support and pushed in peg to secure
Was this helpful?
Thank you for voting!
Door 'clunked' badly when opening
5 of 6 people found this instruction helpful.
  • Eric from San Mateo, CA
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
The door clunk problem was as others described. Repair similar to others described. The major thing to understand which I didn't see listed elsewhere is whether the top or bottom little nylon toothed cam is broken. This part is the one in the door. There was also one in the hinge, PS976594 or PS430814 ? I ordered this one and was luc ky that it was correct. I'm not sure whether it's possible to know whether door side or hinge side is broken, without removing the door to see.
Was this helpful?
Thank you for voting!
Refrigerator Light bulb went out
7 of 12 people found this instruction helpful.
  • ANGELA from MEBANE, NC
  • Very Easy
  • Less than 15 mins
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
Was this helpful?
Thank you for voting!
ice maker would not dispense cubes, stuck on crushed ice
5 of 6 people found this instruction helpful.
  • steven from TONEY, AL
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers, Socket set
turn off ice maker, unplug electoral connection, under bottom of ice maker, remove two screws (hex) under bottom of ice maker, lift up on it to unhook it, take it out. (dump out all ice ). remove back plate on back of ice maker (two screws), the solenoid is held in place with two brass screws, remove them, then remove ground wire from sol enoid and two wires, that connect to it,(make a note of how wires go back !). put it all back together and your good to go. . i dont think its really the solenoid that goes out, its the housing that encases it, and you have to buy another solenoid thats encased. good luck
Was this helpful?
Thank you for voting!
Supply lines needed replacement
5 of 6 people found this instruction helpful.
  • Fred from LAKE JACKSON, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
The line for the water to the door was too short to install. Lacked about 4-6”Ice maker line was fine.
Was this helpful?
Thank you for voting!
Ice maker line was freezing
5 of 6 people found this instruction helpful.
  • John from Ellsworth, WI
  • Easy
  • 15 - 30 mins
  • Screw drivers
Pulled the unit out from the wall and with a flat head screwdriver and a utility knife I replaced the valve assembly. It was no problem at all.
Was this helpful?
Thank you for voting!
crusher housing cracked
5 of 6 people found this instruction helpful.
  • Adam from Clayton, NC
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Removed ice tray, disassembled ice tray assembly and crusher housing making sure to note the spring location, spring etc, installed new plastic housing making sure to reinstall the spring properly and the fixed crusher blade into the notch cutout., reassembled ice tray.
Was this helpful?
Thank you for voting!
Broken Shelf Support Stud
11 of 25 people found this instruction helpful.
  • Kristina from Woodbridge, VA
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
I used pliers to get the remaining shelf support studs out, then the new ones just snapped right in place. Very easy repair!
Was this helpful?
Thank you for voting!
Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
4 of 4 people found this instruction helpful.
  • David from ABINGDON, VA
  • Easy
  • 15 - 30 mins
  • Screw drivers
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the cop per refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
Was this helpful?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people found this instruction helpful.
  • gary from ARANSAS PASS, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Was this helpful?
Thank you for voting!
There was no problem with the installation just finding out what was wrong with it not making ice
6 of 10 people found this instruction helpful.
  • Michael from CANON, GA
  • Very Easy
  • 30 - 60 mins
  • Nutdriver, Wrench (Adjustable)
Replaced bad parts with new parts it went easy
Was this helpful?
Thank you for voting!
All Instructions for the E23CS75DSSH
106 - 120 of 581