Refrigerator stop working
23 of 33 people found this instruction helpful.
  • SAL from UPLAND, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
First I removed the relay and over load and exam. Saw that the relay was burnt. Before I order the part I check to see if the compressor was still working by jumping the common start and run terminals.It did. I also checked the start capacitor with a capacitor tester it was good. I than order the part which came the very next day.Installe d the part
Was this helpful?
Thank you for voting!
The Origional Humidistat Quit Working
10 of 17 people found this instruction helpful.
  • James from Silver Bay, MN
  • Really Easy
  • Less than 15 mins
  • Screw drivers
The knob one turns to set the humidity level was removed. The two screws holding the top on were removed. The top was lifted and swung to the side. After noting which of the two wires went where on the humidistat the wires were removed. Small flat screwdrivers were used to pry back the plastic retainers on one side of the original fai led humidistat. The new one was put in place, the two wires were reattached. The knob was replaced. The top was positioned and its two retaining screws replaced. A magnetic phillips screwdriver was handy but not necessary. Piece of cake! Someone with ten thumbs could do it!! Thanks for the prompt courteous attention to the returned erroneous part! Dealing with partselect. Com was a pleasure. . . . . . Thanks!! P. S. The dehumidifier works like new now!!
Was this helpful?
Thank you for voting!
old fan motor made horrible screeching sound and siezed up
5 of 6 people found this instruction helpful.
  • Dave from Roswell, GA
  • Easy
  • Less than 15 mins
  • Nutdriver
Removed 4 hex head screws around base of metal housing and 2 screws on bottom front holding on plastic grating and one screw holding housing to switch plate at top front. Hinged grating on back just pops off. Removed two screws holding fan motor on. Unclipped wire terminals (2). Bolted new fan in place.

One hitch was that o ne of the little terminal connectors that came with this fan motor was too small, so I had to buy some the right size, and strip the wire and crimp one of those on.

Also, this fan motor is two-speed, and my old dehumidifier is one-speed, so, according to the very helpful instructions, I just taped off one of the wires (not the one I would have guessed--it has you replacing the red with the black and taping off the new red one).

Then reassembled in reverse order, of course.

The only other thing is just that this stinkin' thing was so expensive, but it works fine. It's been humming away for days now, and my basement is once again in the pocket, about 50 - 55% humidity.

And it was pretty easy.
Was this helpful?
Thank you for voting!
the humidity control broke
9 of 18 people found this instruction helpful.
  • larry from tampa, FL
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Taking the case apart and replacing the control unit was a piece of cake. And the part arrived the very day after I ordered it.
Was this helpful?
Thank you for voting!
Dehumidifier froze up to a solid block of ice
5 of 7 people found this instruction helpful.
  • Robert from Ridley Park, PA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
After completely thawing the frozen dehumidifier, I knew the chiller still worked but realized the blower fan did not spin. I ordered a replacement part from PartSelect.com. It arrived in 2 days. With unit unplugged, I removed set knob at the top of the front of the unit, removed two screws at bottom and removed the front grill face ex posing the fan assembly. Next, I unplugged the two fan wires from their connections, removed 4 screws holding fan in place and removed old fan assembly. I then removed the fan blade assembly from old motor by loosing the compression screw and after a thorough cleaning of the fan blades, re-installed it on the new fan motor. The new fan assembly was re-installed with the 4 screws. The fan electrical connections were re-connected. (Note: only the Black and White wires were used as per the original assembly. The Orange wire was left unconnected but bundled with other wires and secured with a tie-wrap.) Dehumidifier was powered up and tested before front grill face was replaced. Mission Complete!
Was this helpful?
Thank you for voting!
Removed the old parts then connected the new parts.
4 of 4 people found this instruction helpful.
  • Jonathan from OLIVE BRANCH, MS
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
The compressor immediately started when I plugged the refrigerator back in. Around 24 hours later the freezer compartment was at 0 degrees, and the refrigerator was at 35 degrees.
Was this helpful?
Thank you for voting!
Refrigerator/Freezer not getting cold.
4 of 5 people found this instruction helpful.
  • Calvin from KELLER, TX
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Determined that compressor was not running, after researching problem on another site they recommended i try the condenser moor fan or motor, the defrost thermostat or defrost timer. . I was not satisfied with their recommendations. If I had tried their recommendations i would have likely gotten frustrated and spent upwards of $3000 to replace the 22 year-old hand me down unit. Thank you Parts Select for properly diagnosing my relay failure saving me a ton of money.
Was this helpful?
Thank you for voting!
the dehumidifier was not shutting off when water level was full
5 of 9 people found this instruction helpful.
  • Steven from Owings Mills, MD
  • Really Easy
  • Less than 15 mins
replaced a piece of the plastic at the top of the bucket that seems to be the water gauge. this seems to be fixed. we are very happy
Was this helpful?
Thank you for voting!
The humidifier would run continuously regardless of the humidity setting.
3 of 4 people found this instruction helpful.
  • Stephen from Richfield, NC
  • Easy
  • Less than 15 mins
  • Nutdriver, Pliers
I removed the old humidistat and replaced it with the new one which was an exact fit.
Was this helpful?
Thank you for voting!
Cimpressor would not start
5 of 11 people found this instruction helpful.
  • Oliver from Madison, AL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Checked compressor with amp meter, and found it was not running, found Overload Switch bad.
When removing old switch watch carefully which lug you move wires from, so you will know which
lug to put the new switch on.

BE SURE YOU KNOW SOMETHING ABOUT
ELECTRICITY!!
Was this helpful?
Thank you for voting!
compressor clicks on for about 5 seconds and then shuts off, evaporator fan is running but no cooling in the fridge.
1 person found this instruction helpful.
  • Scott from Jay, ME
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Disconnect power. Remove back panel on the refrigerator. Relay and overload is a modular unit attached to the compressor. Disconnect module from compressor, install new unit. While you're in there clean the condenser coils with a vacuum and clean the fan and condensate pan. Reassemble, and you're chillin. Total time approx. 15 min.
Was this helpful?
Thank you for voting!
float was missing
2 of 5 people found this instruction helpful.
  • barbra from STERLING HTS, MI
  • Really Easy
  • Less than 15 mins
  • Screw drivers
pried off the plastic fastener with flat blade screw driver set new float in place then pressed plastic fastener back in place
Was this helpful?
Thank you for voting!
Didn't go as well as the last guy....
1 of 2 people found this instruction helpful.
  • Kris from GREEN BAY, WI
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
First....you need a metric nut driver...not a standard...this took me five trips to four stores to find. So if you have this model number don't think it is merely a screwdriver and a Phillips. After that the job was simple but the humidistat did not fix my dehumidifier. It was worth the $38 try ...but sadly off to buy a new one...
Was this helpful?
Thank you for voting!
Push on connectors and switch housing were different
0 of 1 people found this instruction helpful.
  • Lester from Brazil, IN
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
The switch housing was not exactly the same for easy snap in. I removed the actual switch and installed it into the old housing. Then I found that the male pins were larger than the old ones. I chose to clip off the female connectores, strip the wires, and solder the wires to the pins on the switch. It was easier for me than attempting to change the push on connectors. For me, the actual switch was what I wanted and I fixed it my way. It was easy to do however some folks may want to change the push on connectors. Works great and saved me hundreds of dollars. Thanks.
Was this helpful?
Thank you for voting!
After Hurricane Irene refrigeration compressore did not start
1 of 4 people found this instruction helpful.
  • Bobby from New Bern, NC
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Followed the directions. Installation was quick. Took loner to put the covers back on and push the applicance back in position than the repair.
Was this helpful?
Thank you for voting!
All Instructions for the AD02
1 - 15 of 24