Light switch broke
2 of 4 people found this instruction helpful.
  • Carolee from Spokane Valley, WA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Pried out old part with screwdriver. Unplugged. When new part came, just plugged it in and pushed the part into place.
Was this helpful?
Thank you for voting!
grille toe plate broken
1 person found this instruction helpful.
  • Barbara from Shelton, CT
  • Really Easy
  • Less than 15 mins
I removed the old grille toe plate and snapped the new one in it's place.
Was this helpful?
Thank you for voting!
Plugged it in.
1 person found this instruction helpful.
  • Adam from GLOVERSVILLE, NY
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
Was this helpful?
Thank you for voting!
Freezer occasionally had a temperature alarm.Clicking noise also.
1 person found this instruction helpful.
  • Barry from FORD CITY, PA
  • Really Easy
  • Less than 15 mins
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
Was this helpful?
Thank you for voting!
The fridge was running constantly. O
1 person found this instruction helpful.
  • Edward from BILLERICA, MA
  • Very Easy
  • 15 - 30 mins
  • Nutdriver
Once I removed the contents of the freezer I found ice on the inside back panel Removing the panel I found ice on the cooling coils and the defrost thermostat was bulged out where the wires were attached.I removed the panel with the nutdriver as shown in the video. I removed the ice maker connection and removed the panel from the freezer section. I then had to manually defrost the area with a heat gun. The ice had actually covered the Defrost Thermostat - which was bulging where the wires were attached.. The defrosting took the majority of the repair time - the actual Defrost Thermostat replacement only took about 20 minutes once I could get to it. I spliced the wire with a crimping tool as discussed in the video. Once all was defrosted I reversed the operation.Overall, a very simple part change out. The video was extremely helpful - if nothing else to mentally prepare me for the task.
Was this helpful?
Thank you for voting!
No cold
1 person found this instruction helpful.
  • Jacqueline from LEXINGTON PK, MD
  • Very Easy
  • Less than 15 mins
  • Nutdriver, Pliers
Like you video
Was this helpful?
Thank you for voting!
Light rocker switch broke and refrigerator light couldn't go on.
2 of 4 people found this instruction helpful.
  • Cathy from HOPATCONG, NJ
  • Very Easy
  • Less than 15 mins
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
Was this helpful?
Thank you for voting!
suddenly stopped working while in use
2 of 4 people found this instruction helpful.
  • Kevin from Colonia, NJ
  • Easy
  • Less than 15 mins
  • Pliers, Screw drivers
i unplugged the unit,unscrewed the outer shell so that all the wiring and internal components were visible.starting at the first of three micro switches i removed the slip on terminals installed the alligator clips too the wires so the switch would now be bypassed.i made sure the wires and clips were not touching anything plugged unit in and it worked.i then installed the new switch and closed up the outer shell
Was this helpful?
Thank you for voting!
Referigerator section was warm, freezer cold
1 person found this instruction helpful.
  • Thomas from Hicksville, NY
  • Easy
  • Less than 15 mins
  • Nutdriver, Pliers
I removed the back cover in the freezer section by removing six screws. The entire coil, the thermostat and the lines were all iced over. I used a hairdryer to defrost everything. I removed the thermostat by uncoupling the connectors and unclipping it from the coil tubing. I found the thermostat was bulging and deformed. I jumped out the thermostat using an insulated clip lead. I taped it so it would not short to anything. I plugged the unit in, turned the unit to "1" and advanced the defrost timer to defrost. I could hear the water hissing on the coil. I ordered the thermostat. It arrived in 3 days. The new one had a different terminal. I cut off the matching one from the old part and used a scotch-lok to make the connection to the new part. I slapped it in, dressed the wires and replaced the cover. I noticed that when I advanced the timer after replacing the thermostat, it did not immediately come on. The thermostat has an operating temperature window. I checked it several days later and found no frost. Everything works great.
Was this helpful?
Thank you for voting!
freezer and refrigerator compartments not cold enough
1 person found this instruction helpful.
  • Michael from Colorado Springs, CO
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Used the suggested problem list here to narrow down that the repair was most likely the run capacitor. Poped the new one in and I now have better control of my compartment ranges. I have a temperature gauge in each compartment. Check them every opening of the doors.
Was this helpful?
Thank you for voting!
microwave turn table not working
1 person found this instruction helpful.
  • RICHARD from CARY, NC
  • Easy
  • 15 - 30 mins
  • Screw drivers
Removed the phillips screws from the base.

Using a # 10 secure driver, remove the motor. (I recommend obtaining a secure star driver set to be sure you have the right size)

Replace the spacer, which is a separate part from the motor.

Reinstall the spacer and motor.

Reinstall the bottom panel.

Enjoy!
Was this helpful?
Thank you for voting!
freezer would not freeze
1 person found this instruction helpful.
  • Michael from HELENDALE, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thic k. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
Was this helpful?
Thank you for voting!
Condenser fan motor froze up
2 of 4 people found this instruction helpful.
  • Douglas from Mesa, AZ
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Was this helpful?
Thank you for voting!
freezer would not defrost
1 person found this instruction helpful.
  • Robert from Cherokee Village, AR
  • Easy
  • 15 - 30 mins
  • Nutdriver
remove ice maker vent and back piece. Unclip defrost thermostat and unplug. Plug new thermostat in and clip to element, reattach back piece, vent and ice maker. Is a tight fit getting icemaker out, there are 3 screws 2 on top and one on bottom.
Was this helpful?
Thank you for voting!
Circulation fan was not running
1 person found this instruction helpful.
  • Ryan from Otsego, MN
  • Easy
  • 15 - 30 mins
  • Nutdriver
I have a side by side Amana fridge about 12 years old. One day I noticed everything was not cold anymore. I checked the temp with my infrared thermometer and it was about 70 in the top of the fridge, 40-50 in the bottom, and freezer was the same! So after pulling out the two baskets in the bottom of the freezer and the side rails that hol d the baskets, I used a 1/4 nut driver to remove the back lower panel. After looking at the electrical schematic on the back of the fridge, I jumpered around the defrost thermostat, a little cylinder with two wires coming out of it. Bingo, the fan turned on. Well after a few days of running fine with it jumpered my new one arrived. I never really tested my old one with a meter so I did that and it tested fine, so I plugged the old one back in and it worked fine for a few days. Then one day I noticed that fan wasn't running again so I just put the new one in. I had to cut one of the connectors off as it was female instead of male and crimp cap it together, but besides that it went fine. So after connecting it I noticed the fan motor was buzzing but not spinning. I wiggled wires around and determined the connector going into the fan motor had to be a certain way to make the connection. I unplugged it, it wasn't corroded or anything but if pulled down on, it would not make connection. So pulling up on the connector proved that it would make good connection, so a ziptie keeping the wires tight in the up direction proved to be the solution. I'm pretty sure my old defrost thermostat was not the problem. So that's my story. Hope it helped.