Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
refrigerator did not cool
10 of 14 people found this instruction helpful.
  • Carl from Kent City, MI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
i put a new evaporator motor in and now it works fine
Was this helpful?
Thank you for voting!
Water under refrigerator, leaky ice maker water supply solenoid valve
8 of 8 people found this instruction helpful.
  • Eric from Chicago, IL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
This is a relatively simple repair, but requires a bit of running around your house and sitting in a likely cramped space on the floor behind your refrigerator. These steps assume you have verified the valve is leaking and not the lines. 1. Locate where the water line to the fridge connects to the house plumbing. Close the next valve i n the house plumbing upstream of this connection. Open some fixture (likely the cold on the kitchen sink) to relieve water pressure in this section of plumbing. Water should flow briefly, then dribble and stop on its own. 2. Unplug your fridge. There are moving parts (a fan) close to the valve that may injure you while you are working. 3. Pull your fridge away from the wall enough so you can scoot behind and sit behind. 4. Gather your tools and parts and squeeze behind the fridge. 5. Remove the felt paper dust cover. Carefully collect the screws. 6. Take a picture of the electrical connection to the valve or make a mental note. 7. Carefully unclip lines from the fridge and remove screws holding valve to fridge body. Slicing a line will create a new problem to fix. Carefully collect the screws. 8. Remove electrical connection. Grasp the connector and pull firmly. Do not yank the wires. 9. Over the bucket, disconnect old valve from lines. Some residual water will flow out. If the stream is steady, double check that Step 1 is completed correctly. Set old valve aside. 10. Examine new valve to determine water input and outlet. There may be an arrow indicating flow direction. 11. Seat the input line in the valve input firmly and connect. Mine was a nut I tightened with a small crescent wrench. 12. Seat the outlet line in the valve outlet firmly and connect. Mine was a push in quick connect. 14. Rest the valve over the bucket. Get up and turn the water back on. Verify your connections are not leaking. 15. Review your picture and reconnect the electrical connection. 16. Install the new valve onto the fridge body. Mine was a different geometry that required some gentle bending of the mounting bracket. Reclip lines to fridge. 17. While you're down there, vacuum underneath your fridge. 18. Reinstall felt paper dust cover. 19. Plug fridge back in. Clean up. 20. Monitor your ice maker, verify good operation. When satisfied, push fridge back. Recycle(?) old valve. 21. Success!
Was this helpful?
Thank you for voting!
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
9 of 12 people found this instruction helpful.
  • Tim from The Woodlands, TX
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the o ld part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Was this helpful?
Thank you for voting!
The two parts I replaced had rusted. Left rust chips in ice.
9 of 12 people found this instruction helpful.
  • David from Jupiter, FL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I carefully removed the screws and laid aside in order. Taking off the ice grinders was the trickiest part, but I had read before to make sure to keep them in order. Replaced two new parts and reassembled. Pretty simple, but just keep track of where each part goes.
Was this helpful?
Thank you for voting!
Fan had quit; needed replacement.
10 of 15 people found this instruction helpful.
  • John from Divide, CO
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & deliver y were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
Was this helpful?
Thank you for voting!
Door would not close properly
7 of 7 people found this instruction helpful.
  • Dan from New Braunfels, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I stacked three 2x4's that were approximately as wide as the door in length. This required lifting the door about 1/4" but it also got the weight of the door off the cam so the bracket assembly that the cam was attached to could be removed. I drilled out the rivet that held the old cam in place and like previous DIY's had to use a small bolt and nut to secure the new cam in place. Reattached the bracket with the new cam and that was it. The only problem was that the head of the bolt I used was not flat enough to allow proper clearance for the door to swing freely without feeling some drag and the wife noticed that immediately. I told her to wait until the weekend and I would again remove the door and file down the head of the bolt to allow the required clearance. After a few days of use, the door itself ground enough material off the head of the bolt so that the door began to open and close properly. So now she's happy, I'm happy and the dog is happy.
Was this helpful?
Thank you for voting!
Door Closing Cam Disintegrated
8 of 10 people found this instruction helpful.
  • Charles from Hubbardston, MA
  • A Bit Difficult
  • Less than 15 mins
  • Screw drivers, Socket set, Wrench (Adjustable)
The door closing cam on the refrigerator door was a snap to replace. However, I'm still baffled on how to replace the freezer door side. The condensation tube from the door runs through the door pivot and joins to a compression fitting behind the bottom trim piece. The compression ring is behind a formed lip on the tube and won't slide of f. I could cut the tube but I really didn't want to do that. If anyone has done this and knows the trick to replace it, I would appreciate it.

Ed. Please post your question at our repair forums, forums.partselect.com.
Was this helpful?
Thank you for voting!
Plastic light sheild over freezer light had broken.
7 of 7 people found this instruction helpful.
  • George from Louisville, KY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Removed old sheild and reached in freezer replacing sheild with screwdriver. 3 - 4 minutes.
Ordered sheild online one afternoon and received the nest afternoon. Great transaction. will use again when needed.

George in Louisville, KY
Was this helpful?
Thank you for voting!
the veggie drawer fell down from the slide on one side
10 of 16 people found this instruction helpful.
  • Archie from Arlington, VA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
So I looked at it, and saw the slide had actually broken. Immediately copied the Model Number and put THAT number into the Google Box. Up popped the Part Select site -- along with others. There was a perfectly understandable schematic (interactive.) I figured out what I needed, and ordered the parts. They arrived, and the fix was sim ple!!!
No $85 service call
No "We'll be there between 8 and 5"
Simple.
Was this helpful?
Thank you for voting!
tHESE PARTS WERE MISSING FROM MY REFRIGERATOR
7 of 7 people found this instruction helpful.
  • Tim from Byron, IL
  • Really Easy
  • Less than 15 mins
I simply snapped on the kickplate grille, and set the ice maker grille into place. This improved the look and value of my refrigerator.
Was this helpful?
Thank you for voting!
Door Would Not Close Properoy
7 of 7 people found this instruction helpful.
  • Mike from Lake Sherwood, MO
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers, Socket set
Door cam disintegrated after 20 years. This was a terrific site for suggested repairs. My problem was not paying attention to how the door shim, cam and spacer were placed on the hinge. Most of the site's instructions did not forewarn the obvious...pay attention when doing repairs!!

Instructions from others were generally pr etty good but as adept as I am at D-I-Y I still did not pay attention to how I took something apart so it could be assembled properly.

I don't think that ordering an entire door hinge set is necessary. It does not appear that shims and/or spacer come with the hinge assembly. Door cam was all that was needed. I thought about replacing the cam on the freezer side but won't do it until absolutely necessary.

This is a very good website and my thanks to all of the posts for the instructions!!
Was this helpful?
Thank you for voting!
Freezer not getting cold enough to freeze ice cream
8 of 10 people found this instruction helpful.
  • Gary from ROSETO, PA
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
I took the advice off of your website about the only thing that will fix
the problem is change the run capacitor. I felt assured that I would
have a working refrigerator freezer after making this change. I was
pretty disheartened when it didn`t solve anything. I was not going to
take the new part back out after the sma ll challenge of putting it in.
The next day I found out how to test the old capacitor and it was still
good. I will just have to eat the $49. I did learn not to take advice from
a website even if it seems like a sure thing
Was this helpful?
Thank you for voting!
freezer not frezing properly frost buildup
7 of 7 people found this instruction helpful.
  • Bill from Columbiana, AL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
Was this helpful?
Thank you for voting!
Noisy freezer evaporator fan, bearings worn out
8 of 10 people found this instruction helpful.
  • Todd from Saint Paul, MN
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
Was this helpful?
Thank you for voting!
The regrigerator would not defrost properly. After doing some online research, I determined that the Defrost Heater was no longer working.
7 of 7 people found this instruction helpful.
  • David from Lakeland, FL
  • Easy
  • 15 - 30 mins
  • Screw drivers
First, I had to remove the back panel in the freezer. This exposes the cooling coils and the Defrost Heater which is located toward the bottom underneath the cooling coils. There are four screws that have to be removed before the old Defrost Heater can be taken out. There are two wires that go from the Defrost Heater to the power conne ction. These wires are blue and pink. I had to remove some pieces in the back at the top of the freezer to expose the power connection for the Defrost Heater. These pieces were held in place with phillips screws, so they easily came out to reveal the power connection. The power connection is a simple plug-in type. The Defrost Thermostat is also included with the new Defrost Heater. This is a round piece which is clamped onto the Cooling Coils. I removed the old Defrost Thermostat. It is connected to the same power connection with the Defrost Heater. After I mounted the new Defrost Heater and Defrost Thermostat and connected the power, the refrigerator has worked perfectly.
Was this helpful?
Thank you for voting!
All Instructions for the 3973