Refrigerator would turn off and never come back on.
20 of 25 people
found this instruction helpful.
-
Allen from High Point, NC
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Socket set
First unplug the refrigerator!
Removed the top shelf of the refrigerator. Pulled off the knobs from the temp slider controls. Popped the cover off of the light and temp control section. This Hotpoint model has both
thermostat and defrost timer easily accessible in the refrigerator compartment. Used a socket set
dr ... Read more iver to loosen the screws and remove the
temp control section and unplugged the wire connectors. This freed the whole temp control
section. On the workbench removed the old
thermostat by unscrewing the screws with a socket driver. Unplugged the wires from the old thermostat then put the new one in. Then put the
new one in the same holes, reconnected the
wires and reassembled the everything. Then
simply put this temp control box back in the
original place (and reconnect the wire plugs)
and put the screws back in . The hardest part is re-aligning the holes and the control levers, but this is not too bad.
Plugged it back in and so far it has been turning
on and off normally. (The old thermostat contacts
were oxidized so I think this was the problem).
Removed the top shelf of the refrigerator. Pulled off the knobs from the temp slider controls. Popped the cover off of the light and temp control section. This Hotpoint model has both
thermostat and defrost timer easily accessible in the refrigerator compartment. Used a socket set
dr ... Read more iver to loosen the screws and remove the
temp control section and unplugged the wire connectors. This freed the whole temp control
section. On the workbench removed the old
thermostat by unscrewing the screws with a socket driver. Unplugged the wires from the old thermostat then put the new one in. Then put the
new one in the same holes, reconnected the
wires and reassembled the everything. Then
simply put this temp control box back in the
original place (and reconnect the wire plugs)
and put the screws back in . The hardest part is re-aligning the holes and the control levers, but this is not too bad.
Plugged it back in and so far it has been turning
on and off normally. (The old thermostat contacts
were oxidized so I think this was the problem).
Read less
Was this helpful?
Thank you for voting!
Refrig. Side not cooling enough
22 of 31 people
found this instruction helpful.
-
William from Moorestown, NJ
- A Bit Difficult
- More than 2 hours
-
Nutdriver, Screw drivers
Replaced several things: evaporator fan motor, defrost heater element & defrost timer. The motor was the key problem but did the other repairs because they are common failures and are easy to replace and are not that expensive. Changing the motor was tedious because of tight access to it. Took about 2 hrs for me. Fan is working properly b
... Read more
ut not have a problem with water to ice maker not shutting off. I'm researching that problem. (I replace the water valve 2 hrs ago. That was a simple task - took 15 mins.)
Read less
Was this helpful?
Thank you for voting!
The refrigirator light would not come on.
26 of 44 people
found this instruction helpful.
-
Jania from Novato, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this helpful?
Thank you for voting!
Ice maker would not make ice..
19 of 23 people
found this instruction helpful.
-
James from Mebane, NC
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmm ... Read more eter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmm ... Read more eter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Read less
Was this helpful?
Thank you for voting!
Frig would stop working every so often. Lots of food got spoiled.
17 of 19 people
found this instruction helpful.
-
Rene from Bronx, NY
- Really Easy
- Less than 15 mins
-
Nutdriver
Got part overnight. Unscrewed cover plate at top of regerator compartment, disconnected old part, connected new part. Screwed back plate. Voila!
I saved a bunch of money!
I saved a bunch of money!
Was this helpful?
Thank you for voting!
Stripper on the icemaker broke into pieces.
18 of 23 people
found this instruction helpful.
-
Tracy from Yuba City, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this helpful?
Thank you for voting!
Broken water line near solonoid to feed drinking water
20 of 29 people
found this instruction helpful.
-
Gregory from Yucca Valley, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
Other Parts Used:
Was this helpful?
Thank you for voting!
Refrigerator to warm freezer ok
16 of 18 people
found this instruction helpful.
-
Christopher from Madison Heights, MI
- Easy
- Less than 15 mins
-
Nutdriver
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a whil
... Read more
e I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Read less
Was this helpful?
Thank you for voting!
Compressor overheating - Fridge not Cooling
16 of 19 people
found this instruction helpful.
-
CHRIS from LAGUNA NIGUEL, CA
- Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds
... Read more
the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Read less
Was this helpful?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
15 of 17 people
found this instruction helpful.
-
D from ZELLWOOD, FL
- Easy
- 15 - 30 mins
-
Screw drivers
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Was this helpful?
Thank you for voting!
My 13 yr grandson assisted me on this
15 of 18 people
found this instruction helpful.
-
Sherry from Auburn Hills, MI
- Really Easy
- Less than 15 mins
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Was this helpful?
Thank you for voting!
Water and Ice acuator had a hole in it. Need to be replaced.
15 of 18 people
found this instruction helpful.
-
Lowell H from Gilbert, AZ
- Really Easy
- Less than 15 mins
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.
Was this helpful?
Thank you for voting!
Water Leak From The Ice Make - Water All Over The Frig
14 of 15 people
found this instruction helpful.
-
David T from Irvine, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to ident
... Read more
ify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.
Read less
Was this helpful?
Thank you for voting!
water line leaking behind refigerator
14 of 15 people
found this instruction helpful.
-
Michael from Merrimac, MA
- Easy
- 15 - 30 mins
-
Pliers
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everyt
... Read more
hing works fine with no leaks
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
freezer freezing up
16 of 21 people
found this instruction helpful.
-
richard from cleburne, TX
- Really Easy
- 15 - 30 mins
-
Screw drivers
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
Was this helpful?
Thank you for voting!