Icemaker producing few or no cubes and often leaving "kling-ons" on ice tray
816 of 915 people
found this instruction helpful.
-
Bernie from Diamond Bar, CA
- Easy
- 30 - 60 mins
-
Nutdriver
Interior surface of ice tray felt rough & flaky (coating deteriorated) so cubes would not release.
Unplug appliance.
Remove timer cover by hand pressure @ edge.
Remove single attachment screw & bracket at lower front of icemaker.
Disconnect wiring harness from socket @ rear of compartment.
Tricky part was determin ... Read more ing what type of connection held the other two attachment points along the long edge of the icemaker. I did not have repair manual or useful drawing but looked @ PartsDirect pic of side brackets & used a small mirror to confirm that mine were also some sort of "snap in" attachment.
Remove icemaker unit by pushing upward and outward on the unit. I takes a good bit of pressure and will pop loose, but be careful not to break attachment bracket from freezer wall.
Scavenge shut off bar and wiring harness from old icemaker once you have it out & attach to new one before installing it back in freezer.
Again, you might find a mirror useful to align those pesky snap-in brackets with the new unit.
Since you probably kept your freezer running while waiting for the part, the plastic snap-ins will be cold and brittle. I warmed them up first by applying a dampened cloth heated in the microwave to make them a little more pliable.
A good push of the new unit towards the snap-ins along with some upward force will get it stable.
Reattach the metal screw in bracket & connect the wiring harness to rear plug... and don't forget to plug the whole thing back in.
It will take awhile for the first batch of cubes dump as the timer may need to cycle completely around to get to the fill cycle... be patient.
Dump the first couple of batches of cubes just to make sure you're free of any residue.
Unplug appliance.
Remove timer cover by hand pressure @ edge.
Remove single attachment screw & bracket at lower front of icemaker.
Disconnect wiring harness from socket @ rear of compartment.
Tricky part was determin ... Read more ing what type of connection held the other two attachment points along the long edge of the icemaker. I did not have repair manual or useful drawing but looked @ PartsDirect pic of side brackets & used a small mirror to confirm that mine were also some sort of "snap in" attachment.
Remove icemaker unit by pushing upward and outward on the unit. I takes a good bit of pressure and will pop loose, but be careful not to break attachment bracket from freezer wall.
Scavenge shut off bar and wiring harness from old icemaker once you have it out & attach to new one before installing it back in freezer.
Again, you might find a mirror useful to align those pesky snap-in brackets with the new unit.
Since you probably kept your freezer running while waiting for the part, the plastic snap-ins will be cold and brittle. I warmed them up first by applying a dampened cloth heated in the microwave to make them a little more pliable.
A good push of the new unit towards the snap-ins along with some upward force will get it stable.
Reattach the metal screw in bracket & connect the wiring harness to rear plug... and don't forget to plug the whole thing back in.
It will take awhile for the first batch of cubes dump as the timer may need to cycle completely around to get to the fill cycle... be patient.
Dump the first couple of batches of cubes just to make sure you're free of any residue.
Read less
Was this helpful?
Thank you for voting!
burned in half
544 of 548 people
found this instruction helpful.
-
mike from gold bar, WA
- Really Easy
- Less than 15 mins
-
Screw drivers
put the new element in the oven pushed wire onto connector on element held it up to match holes and put the screws back in, very easy to change. I really like the fast way I receive a part from you.
Was this helpful?
Thank you for voting!
My refrigerator stopped cooling and the freezer section stopped freezing
442 of 557 people
found this instruction helpful.
-
garth from forest lake, MN
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck le
... Read more
t's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
Read less
Was this helpful?
Thank you for voting!
Water overflowed ice maker turnning ice bucket into solid mass of ice
280 of 383 people
found this instruction helpful.
-
Harry from Grand Ledge, MI
- A Bit Difficult
- 30 - 60 mins
-
Pliers, Screw drivers
My ice maker has been shedding its non-stick coating for over a year. Within the last month of so, it started pouring water into the ice bucket below, turning it into a solid mass of ice. So I purchased a new ice maker assembly. I encountered two problems not mentioned in the 21 or so do-it-yourselfer repair stories that precede this on
... Read more
e. First problem: one of the three screws that hold the ice maker to the refrigerator wall is hidden behind the large (black) end of the ice maker and is difficult to access. Before trying to replace the ice maker, make sure you have the physical dexterity to remove that screw. Second problem: it is not apparent how to remove the wire harness that plugs into the ice maker assembly. BEFORE you can remove the wire harness, you MUST remove the large white cap that covers the black end of the ice maker assembly and then push in a retaining tab to release the wire harness. If you don't do this, the wire harness will not release. Other than those two problems, it was relatively easy to remove three screws, unplug the wire harness, transfer three small, metal parts from the old ice maker to the new, plug in the new wire harness, mount the ice maker assembly so that the water tube is in the proper position, and then re-install the three screws. The ice maker works fine now. (P.S. I was told by an expert that the real problem might be a malfunctioning fill valve. I would have replaced the fill valve if replacing the ice maker assembly had not fixed the problem.)
Read less
Was this helpful?
Thank you for voting!
No heat - element had burst.
236 of 302 people
found this instruction helpful.
-
John from Marion, IA
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Unscrewed 2 screws holding terminal ends of the element in place. Eased the element out, until the two AC power wires were exposed. Pulled off the connectors from the element terminals (pretty tight fit - needed pliers to remove one of them).
Slipped the connectors onto the new element terminals, and eased the element back int ... Read more o the oven wall. Secured the element with the two screws removed previously, and that was pretty much all there was to it. Closed the circuit breakers, and the element tested OK.
Overall, a no-sweat job. One thing, though: I squeezed the oven connectors tight before pushing them back onto the new element. They had loosened up somewhat after pulling them off. A tight connection here seems pretty important, as arcing and corrosion could occur over time if they're too loose.
Slipped the connectors onto the new element terminals, and eased the element back int ... Read more o the oven wall. Secured the element with the two screws removed previously, and that was pretty much all there was to it. Closed the circuit breakers, and the element tested OK.
Overall, a no-sweat job. One thing, though: I squeezed the oven connectors tight before pushing them back onto the new element. They had loosened up somewhat after pulling them off. A tight connection here seems pretty important, as arcing and corrosion could occur over time if they're too loose.
Read less
Was this helpful?
Thank you for voting!
No power to the fan and compressor
222 of 302 people
found this instruction helpful.
-
Christian from Kearneysville, WV
- Really Easy
- Less than 15 mins
-
Screw drivers
I have a fridge in my garage. I have found that a glass of ice water or a cold drink outside is very important to me. When I discovered melting ice dripping onto the garage floor I was very upset. I spun the fridge and found that the compressor and fan weren't starting. I got out my multi-meter and discovered that power was not makin
... Read more
g it to these components. I did some research and found the wiring diagram online. There really isn't too much going on with a fridge and the most likely candidate seemed to be the run capacitor. I ordered the part, replaced it in a few minutes and the fridge began working again.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Sometimes the condenser fan would start causing the refrigerator to overheat.
189 of 228 people
found this instruction helpful.
-
Tom from Franklin, WI
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers
Unplug the appliance.
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut ... Read more and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut ... Read more and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
Read less
Was this helpful?
Thank you for voting!
Fridge and freezer didn't cool enough
106 of 117 people
found this instruction helpful.
-
Peter from Eden, UT
- Really Easy
- Less than 15 mins
-
Socket set
I diagnosed the problem via the internet. Diagrams helped a lot. Coils were frozen over. Thawed them out overnight. Manually advanced timer and the defrost heater was operable. The defrost timer wasn't "turning" on it's own. I turned the fridge back on while I awaited the part. It worked fine for the time I had to wait. (over two
... Read more
weeks since I had delayed ordering the part) New timer arrived as promised. Undid 4 hex head (1/4") screws. Unplugged 4 prong connection. Plugged in new timer and replaced the 4 screws. Frigde works great.
Read less
Was this helpful?
Thank you for voting!
Bake element burnt out
132 of 195 people
found this instruction helpful.
-
Glenn from Jupiter, FL
- Really Easy
- Less than 15 mins
-
Screw drivers
Before you touch anything unplug the range or trip the breaker. Pull the racks out of the oven, it gives more room to work. Remove the two screws that hold the element and pull the element out about 2-3". Disconnect the old element. Before you install the new element check the wire and the connectors for age and heat damage. If the connec
... Read more
tors are loose replace them (2 connectors @ $1.97 is better than a short in the oven). If the insulation on the wire is degraded (brittle, flaking, brown) consider changing out the wiring. This means opening up the back of the oven and that is another chapter. In most cases you can just re-connect to the replacement element and attach it back to the oven with the two screws. I ran the oven to 400 degrees to just check that everything was OK. Spent a couple extra minutes to check everything out and save yourself pain later.
Read less
Was this helpful?
Thank you for voting!
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
110 of 140 people
found this instruction helpful.
-
David from Chester, CA
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing
... Read more
the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
Read less
Was this helpful?
Thank you for voting!
Heating Element would not heat up for Baking
87 of 91 people
found this instruction helpful.
-
Karen from High Springs, FL
- Easy
- Less than 15 mins
-
Screw drivers
Removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires and then replaced the new heating element by connecting the wires and then placing the screws back in. Was a lil difficult because this unit has no oven light and it required a flash light.
Was this helpful?
Thank you for voting!
Lights inside refrigerator not working
138 of 259 people
found this instruction helpful.
-
Clint from Rayville, MO
- Really Easy
- Less than 15 mins
-
Screw drivers
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Was this helpful?
Thank you for voting!
Door would not close
79 of 84 people
found this instruction helpful.
-
Russ from Asheville, NC
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
After emptying the refrig. door, I unscrewed the plate on the top of the refrigerator that covered the door bolts. Then off with the three bolts. I removed the door by lifting it up a few inches. The two parts of the door cam were easily removed and replaced with the new part. BEFORE REPLACING the door spread vasoline on both cam parts.
... Read more
(Not after as I did. The second time you do any of these repairs go SO much better :o)
After putting the door back on, adjust the tension of the screws holding the door in place if needed to align the door on the cams so that it shuts completely. Failure to do this will require taking the top off the door again. (see comment above on "... second time...")
If all is properly aligned, the door should swing completely shut.
Even with the mistakes that required removing the door to lubricate the cams, and removing it AGAIN to readjust the screws on the top to properly align the door on the cams, this was a twenty minute job. My wife and I were still speaking to one another at the end of it- a sure sign of an easy repair.
(Not after as I did. The second time you do any of these repairs go SO much better :o)
After putting the door back on, adjust the tension of the screws holding the door in place if needed to align the door on the cams so that it shuts completely. Failure to do this will require taking the top off the door again. (see comment above on "... second time...")
If all is properly aligned, the door should swing completely shut.
Even with the mistakes that required removing the door to lubricate the cams, and removing it AGAIN to readjust the screws on the top to properly align the door on the cams, this was a twenty minute job. My wife and I were still speaking to one another at the end of it- a sure sign of an easy repair.
Read less
Was this helpful?
Thank you for voting!
The Burner was getting too hot and you could not regular the tempature
77 of 89 people
found this instruction helpful.
-
Dennis from Hagerstown, MD
- Really Easy
- Less than 15 mins
-
Screw drivers
Moved the Appliance out unplugged it and removed the backing plate then Remove the Knob and unscrew the infinite switch then marking the 5 wires to know where the go on the new switch, removing and replaced it with the new one
Was this helpful?
Thank you for voting!
not making ice
78 of 93 people
found this instruction helpful.
-
Pat from Dallas, TX
- Really Easy
- 15 - 30 mins
-
Screw drivers
Installed new ice maker. It was easy - loosen two screws and unplug old wire harness. Put new unit in place. Did not realize new unit would not come with wire harness, but transferred old one to new ice maker (easy) and, "voila" some ice in 24 hours -- much ice since then. I am a 68 year old woman and it was "sort of fun" doing thi
... Read more
s job.
Read less
Was this helpful?
Thank you for voting!