106R14 Kenmore Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
wouldn't make ice, door seal was hot to touch, warm in fridge.
-
Dale from Sterling, AK
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Socket set
I folded in half twice! and took the back off the fridge(cardboard) and took one brace off and just took the screws off the fan from the other two braces. Turned the fan enough to get at the wires for the fan and cut them off an inch from the old fan, stripped the insulation and wire nutted them to new fan. Make sure they don't interfere
... Read more
with the new fan and put the new fan in place put the screws in and we're making ice and cold fridge again.
Read less
Was this helpful?
Thank you for voting!
New Part Was Different From Previous Part
-
Robert from Metuchen, NJ
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
First attempt was difficult. Part was different and instructions applied to previous part that did not have quick connect. Not clear where quick connect was to be used. Result no ice!second attempt used quick connect in reverse connections and now have plenty of ice. Combination of change in part appearence from previous one ,and diff
... Read more
erent from instructions included with new part, resulted in confusion in installation. In the long run, it worked out well.
Read less
Was this helpful?
Thank you for voting!
not cooling
-
larry from indianapolis, IN
- Difficult
- More than 2 hours
-
Pliers, Socket set, Wrench set
removed condenser fan -located behind refrigerator next to compressor, Not much clearance to work, there are 3 screws to remove from condensing motor,sounds easy but clearance is lacking to remove them ,(takes alot of PATIENCE). Then you have to remove the fan blades to be able to get clearance to remove motor!! I wouldn't reccommend tryi
... Read more
ng this repair unless you are a pro.
Read less
Was this helpful?
Thank you for voting!
Not cooling properly/ door divider getting hot.
-
Timothy from Granite City, IL
- Difficult
- More than 2 hours
-
Nutdriver, Wrench set
The video of the repair is a helpful guide, but my refrigerator has the compressor very close to the condenser fan motor. With the compressor comes the copper tubing that is all in the way. I had to carefully bend them now and then to allow me to get my hands in position. The how to is easy, but the working with tools in cramped quarters
... Read more
was difficult. I think my Maytag side by side model makes for this job to be difficult, maybe yours may not be so bad. I took a couple of hours to complete. After the first hour, I covered the bare wires, and plugged the frig back in so it could do some cooling. I placed a small in front on the condenser to blow across it. Had a little break, then finished the job.
Read less
Was this helpful?
Thank you for voting!
Soleniod Valve Failed
-
BOB from LAKE HAVASU CITY, AZ
- Difficult
- More than 2 hours
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
The refrig. Is about 30 years old. The new solenoid looked and mounted nothing like the original. I driled holes in the frig and attach the solenoid with sheet metel screws. There were not enough fittings and hoses so I bought a braded metal hose to attach the ro line and the valve inlet. I used the parts in the kit to attach the
... Read more
water feed line. To the ice maker I did not try to stuff all the hoses and lines back into the cramped cavity in the frig. W ell how does it look? The solenoid sticks out a little and there are a lot of hoses behind the frig. I do not spend much time behind the frig so who cares. The ice maker is making ice!
Read less
Was this helpful?
Thank you for voting!
Fan motor stopped working
-
john from white pine, TN
- Really Easy
- More than 2 hours
-
Screw drivers, Socket set
Well I could what laid on the floor and replaced it but I didn't I emptied refrigerator laid it over change the motor then stood it back up actual work about three hours
Was this helpful?
Thank you for voting!
not makinig ice due to lack of water flow to maker
-
David from Manlius, NY
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers
Followedinstructions that came with kit. Kit parts were unnecessary as new valve fit in exactly as old one had been. Quick connect for flow out of valve to maker was a surprise as no threaded connection present and no nut necessary; simiply push the line into place. Reconnect water line, check for leaks and refasten back covering. Inst
... Read more
ructions with kit contained an incorrect drawing of connecting water outflowline; a one page addition verbally gave correct info, but detailed step by step instruction for this one connection was confusing. Otherwise, could not have been easier; surely a do-it-yourself project.
Read less
Was this helpful?
Thank you for voting!
See below
-
Patricia from Hobe Sound, FL
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
The defrost timer that I ordered form you did the trick. My fridge was
running all the time and the fridge temp was 55 but the freezer was 10
below. The instructions did not say how to test the old one to compare with
the new on. However in the Readers Digest Home Repair book it did and the
test proved that it was defe ... Read more ctive. Your article said that with the system I
had, 65% on the time it was the timer. I ordered it and thank you it works
just fine. I do have another problem, maybe you can help. The fridge runs
for 6 minuets and stays off for 10 minuets. The temp in the freezer is 0
and the fridge is 35-40 on the warmest settings, but all is well.
Thank you
running all the time and the fridge temp was 55 but the freezer was 10
below. The instructions did not say how to test the old one to compare with
the new on. However in the Readers Digest Home Repair book it did and the
test proved that it was defe ... Read more ctive. Your article said that with the system I
had, 65% on the time it was the timer. I ordered it and thank you it works
just fine. I do have another problem, maybe you can help. The fridge runs
for 6 minuets and stays off for 10 minuets. The temp in the freezer is 0
and the fridge is 35-40 on the warmest settings, but all is well.
Thank you
Read less
Was this helpful?
Thank you for voting!
Freezer was too cold and refrigerator was too warm
-
Jolinda from Eau Claire, WI
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set
After receiving the part, I watched the installation video on the PartSelect website. The step by step demonstration was excellent. I felt confident I could do it myself after watching the video just once, and utilizing the written instructions that came with the part. The installation went smoothly, and my refrigerator is functioning
... Read more
correctly again. Best of all, I did not have to go through the hassle and expense of hiring a repair person!
Read less
Was this helpful?
Thank you for voting!
frosted evaperator
-
Burton from Mount ShaSTA, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
I was a Sears repair man for fourty eight years , so I don"t think I should say how easy this was.
Was this helpful?
Thank you for voting!
Water was running into refrig from freezer and ice cream was soft
-
William from Delano, MN
- Really Easy
- Less than 15 mins
-
Nutdriver
We wasted time looking for the electrical schematic on our refrigerator (the first step in the instructions). By skipping that and reading further in the instructions, the type of cooling that the refrigerator has can easily be determined by the colors of the wires that go to the defrost timer. You need to know this to set up the timer
... Read more
properly for your specific refrigerator. Had I just started there, the entire repair would have taken less than 10 minutes. Very simple repair and it works like a charm, no more water coming into the refrigerator and the ice cream is rock hard. Glad we didn't have to spend lots on a new appliance. Thanks Part Select.com! BH
Read less
Was this helpful?
Thank you for voting!
Refrigerator not cooling
-
John from Niles, MI
- Easy
- Less than 15 mins
-
Pliers, Screw drivers
Unloading the freezer and removing the back panel were the most time consuming aspect of this repair. Many models only have 4 screws, but this one has 9, and being a side by side it was a tight fit to reach them. Once defrosted we tested the thermostat, found it "dead", and ordered a new one. The part came within 3 business days. Insta
... Read more
lling it took minutes, since we had not permanently screwed in the back panel again. We didn't want to reload everything until we knew things worked properly, so we didn't put everything back right away. We thought we had further problems as the freezer got really cold but the frig still didn't get down to temp. Turns out we just needed to reinstall the fan shield which we'd taken off along with other parts to access and check the vents. The fan shield must be in place to direct the cold air into the vent to the refrigerator. Duh! It was an oversight that once caught made total sense! Now all works fine on this 20 year old Maytag side by side!
Read less
Was this helpful?
Thank you for voting!
The Refrigerator Was Running But Blowing Hot Air, Everything In Freezer Had Defrosted.
-
Jeanne from Fairview Heights, IL
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
First I watched the video on your website, it was quite helpful. It showed me the location of the part to be replaced. Then I used the nut driver to remove a couple of screws, and slowly pulled the cover off . Once I pulled the cover down I could see the part that needed replacing, it had a couple of phillips head screws holding it in
... Read more
place, I removed those screws and unplugged the defrost timer, taking note of the color of the wires. Then I took the new defrost timer and attached the loose wire to the correct terminal according to the directions(this is where the color of your wires comes in), then I plugged in the new defrost timer and replaced the screws. I then reattached the cover making sure not to pinch any of the wires, and replaced the screws. It was so easy I was sure I did something wrong and it wouldn't work, but I plugged the refrigerator back in and let it sit for about 20 minutes and then when I checked it was running cool. I'm 55 years old and never had the nerve to try anything like this before but since my husband passed away I've had to try things myself or replace a lot of appliances. If I can do it anyone can.
Read less
Was this helpful?
Thank you for voting!
Evaporator Would Freeze Up And The Food Section Could'nt Cool
-
michael from buchanan, TN
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
I just followed the enclosed instructions
Was this helpful?
Thank you for voting!
Freezer was not getting cold enough
-
David from Salem, WI
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
Mine was alittle different than the online instructions. 1. I removed the motor. 2. I took the fan off the old motor and cut the wires about 3" back from old motor. 3. Mounted the new fan on bracket and put the fan on the new motor. 4.connected wires that were cut and used wire nuts to connect. 5. Mounted bracket and motor/fan to unit and
... Read more
it works like its brand new. Thank you PartSelect!
Read less
Was this helpful?
Thank you for voting!