Original drawer handle had cracked and the crack spread down to the body of the crisper unit.
2 of 3 people
found this instruction helpful.
-
Scott from JAY, VT
- Very Easy
- Less than 15 mins
Took out the old, cracked, crisper unit and removed the white trim piece on the handle so that we could re-use it on the new crisper unit (which, in spite of the $90+ price tag did not come with new trim). The whole thing took 3 minutes to do.
Was this helpful?
Thank you for voting!
door hinge broke.
2 of 4 people
found this instruction helpful.
-
Bernard from DONALDSONVLLE, LA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Removed door and replaced bushing bracket was ok.
Was this helpful?
Thank you for voting!
no drawer
1 person
found this instruction helpful.
-
Xiaoping from KIRKLAND, WA
- Really Easy
- Less than 15 mins
just insert
Was this helpful?
Thank you for voting!
No cold
1 person
found this instruction helpful.
-
Jacqueline from LEXINGTON PK, MD
- Very Easy
- Less than 15 mins
-
Nutdriver, Pliers
Like you video
Was this helpful?
Thank you for voting!
Freezer occasionally had a temperature alarm.Clicking noise also.
1 person
found this instruction helpful.
-
Barry from FORD CITY, PA
- Really Easy
- Less than 15 mins
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
Was this helpful?
Thank you for voting!
My refrigerator would not defrost.
1 person
found this instruction helpful.
-
Eddie from BRONSTON, KY
- Very Easy
- Less than 15 mins
The first part I changed was the defrost timer but it did
not solve the problem, I replaced the bi-metal defrost sensor
and I have the same problem.
I can defrost by turning the clock manually and heater works.
... Read more
problem.
not solve the problem, I replaced the bi-metal defrost sensor
and I have the same problem.
I can defrost by turning the clock manually and heater works.
... Read more
problem.
Read less
Was this helpful?
Thank you for voting!
3 screws
1 person
found this instruction helpful.
-
Michael from SALINA, KS
- Very Easy
- Less than 15 mins
-
Nutdriver
Ice maker fit perfectly over 2 top screws. I tightened them and put the one on the bottom. I was done in less than 10minutes. Everything fit perfectly as expected. Couldn't have been eaiser. Parts Select is my go to online store.
Was this helpful?
Thank you for voting!
door Shelf end cap was broken
1 person
found this instruction helpful.
-
Leora O from PIERZ, MN
- Very Easy
- Less than 15 mins
I just snapped it into place. Easy Peasy!!!!
Was this helpful?
Thank you for voting!
compressor not running
1 person
found this instruction helpful.
-
Doug from Lancaster, CA
- Really Easy
- 15 - 30 mins
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
Was this helpful?
Thank you for voting!
Freezer was working but fridge was barely cooling. Look further into how to test thermostat.
1 person
found this instruction helpful.
-
Bonnie E from MODESTO, CA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver
I just replaced my defrost thermostat after using the place-in-ice-water method, and I think it may not have been necessary. My timeline: my fridge was not getting cold enough. I realized it the day before going on a trip. I vacuumed the (very dusty) coils at the bottom, and the next morning the fridge seemed colder, but I thought I s
... Read more
hould order parts just in case. I ordered a heater and a thermostat. The fridge seemed to be operating normally when I returned from my trip, but I had the parts, so I thought I'd go ahead and dismantle the freezer and test the existing parts. My intention was to return both parts if the old ones passed the tests. I opened up the back of the freezer and there was no ice on the fins. I thought, great, the existing heater works! I cut out the thermostat, placed it in ice water, and didn't get continuity. So I decided to go ahead and put in the new thermostat. Because I'm not experienced with using a multimeter, I thought I'd test the new thermostat to see how the test should work. To my surprise, the new thermostat also failed the test! Stumped, I thought I might as well install the new thermostat, since I had opened the package and couldn't return it.
Further internet research suggests the place-in-ice-water method of testing is not adequate. One YouTube video by Parts Dr says to place the part in a working freezer. I froze my old thermostat and tested it; still no continuity. This thermostat may not be typical, though. The video discussed the temperature ratings on thermostats. The temperature rating on both (old and new) thermostats is L8.9-16.7C. That converts to 48-63 degrees fahrenheit, which obviously are not freezing temperatures. I'm not convinced I needed a new thermostat, but I trusted the videos I consulted earlier.
I cleaned the fridge thoroughly, so at least now I have a nice clean fridge to show for my efforts.
Further internet research suggests the place-in-ice-water method of testing is not adequate. One YouTube video by Parts Dr says to place the part in a working freezer. I froze my old thermostat and tested it; still no continuity. This thermostat may not be typical, though. The video discussed the temperature ratings on thermostats. The temperature rating on both (old and new) thermostats is L8.9-16.7C. That converts to 48-63 degrees fahrenheit, which obviously are not freezing temperatures. I'm not convinced I needed a new thermostat, but I trusted the videos I consulted earlier.
I cleaned the fridge thoroughly, so at least now I have a nice clean fridge to show for my efforts.
Read less
Was this helpful?
Thank you for voting!
freezer would not freeze
1 person
found this instruction helpful.
-
Michael from HELENDALE, CA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thic
... Read more
k. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
Read less
Was this helpful?
Thank you for voting!
My Crisper Pan was broken so I needed a new one.
2 of 4 people
found this instruction helpful.
-
Debra from Lakewood, CA
- Really Easy
- Less than 15 mins
I ordered a new one waited for the new ones to come in once it did I took out the old ones and replaced them with the new ones. It was simple.
Was this helpful?
Thank you for voting!
The Light Socket Burned Out.
5 of 13 people
found this instruction helpful.
-
MATTHEW from STOCKTON, CA
- Really Easy
- Less than 15 mins
I pulled the socket out and unplugged the wires. I replaced the light socket by plugging in the wires and snapping the light socket into place. A very simple fix.
Was this helpful?
Thank you for voting!
Plugged it in.
1 person
found this instruction helpful.
-
Adam from GLOVERSVILLE, NY
- Really Easy
- Less than 15 mins
-
Nutdriver
Not so good that was not the problem. Fan is not seized and all the lights work and display is not on but lights up as well. No start once plugged back in after 15 minutes of being unplugged. Nothing same no change.
Was this helpful?
Thank you for voting!
compressor clicks on for about 5 seconds and then shuts off, evaporator fan is running but no cooling in the fridge.
1 person
found this instruction helpful.
-
Scott from Jay, ME
- Really Easy
- Less than 15 mins
-
Nutdriver
Disconnect power. Remove back panel on the refrigerator. Relay and overload is a modular unit attached to the compressor. Disconnect module from compressor, install new unit. While you're in there clean the condenser coils with a vacuum and clean the fan and condensate pan. Reassemble, and you're chillin. Total time approx. 15 min.
Was this helpful?
Thank you for voting!