Freezer was icing up and leaking. Refrigerator side would not keep cold.
3 of 3 people found this instruction helpful.
  • Camille from Glen Ellyn, IL
  • Easy
  • More than 2 hours
  • Nutdriver, Pliers, Screw drivers
We emptied out both sides, refrigerator and freezer, and followed the instructions in your video. We turned it off and disconnected the power. We took off the freezer door first. It made it much easier to get the shelves out and reach way back into the freezer. We removed the light and cover, then the ice auger motor. The back panel wa s easy to lift and remove. The wire assembly was a little hard to understand at first, but when we figured it out it was easy to remove and replace the bimetal defrost thermostat. We did check the video when we had the wire harness out, to make sure we got it right. We reassembled the freezer's inside parts and reattached the door. Before we turned the power back on, we scrubbed down the entire refrigerator. When we turned the power back on, the refrigerator and freezer were operating quietly - no sparks or explosions or shorting out - hooray! And the problems were solved.
The most important resource is your video. It looked like something we could do, and then ordered the parts. Our repair took a long time because we checked the video so many times. Thank you so much for the great information and the excellent parts. We could not have done it without you.
Was this helpful?
Thank you for voting!
Top half of freezer & fridge were not cooling. Freezer fan had been making unusually loud noises.
3 of 3 people found this instruction helpful.
  • rich from PEMBROKE PNES, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver
Piece of cake. It took me longer to remove the food from the freezer, remove shelves and back panel than to do the repair. I heard the fan making some noises so I replaced both the fan and defrost thermostat. I used the instructions submitted by a another customer. My 20+ year old fridge is like new now.
Was this helpful?
Thank you for voting!
light on inside, fridge and freezer warm up after initially cooling
3 of 4 people found this instruction helpful.
  • paul from patterson, CA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Fridge/freezer warm. After unpluging and plug in again, both would get cold. Then, ice would partially melt in the freezer only to refreeze later. Noted large temperature swings in freezer-up to 48 degrees during defrost cycle. Finally after a day or two, both sides warming up permanently to room temp. Tapping inside the fridge near th e cold control (thermostat) would cause the warm fridge/freezer to cool again. Installation is simple. Remove knobs and snap on face plate in front top of fridge. Remove screws allowing plastic cover to drop down which houses the thermostat at the inside top of fridge. loosen two mounting hex head screws from thermostat mount. Remove two plastic covers concealing thermostat wire that travels to vent at back of fridge. Remove thermostat. remove plastic tube over wire on old thermostat by slipping it forward and slide tube on to new thermostat wire. Install is the same in reverse. A thermometer in the freezer confirms very little temperature variation after install (3-4degrees); ice no longer melts, unit stays on!
Was this helpful?
Thank you for voting!
Refrigerator would not stay cold and freezer would thaw.
3 of 4 people found this instruction helpful.
  • Michael from SYLVA, NC
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I watched the repair video and did exactly as described. Excellent video and step by step instructions. Follow them and you cannot go wrong.
Was this helpful?
Thank you for voting!
shelf stud had broken
3 of 4 people found this instruction helpful.
  • cal from lakeside, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers
pryed out old stub of stud with the tip of a flat head screw driver. It really did not want to come out because of the metal wings on the side of the stud. When I finally got it out the hole was a little rough but the new stud fit in the old hole and was not to wobbley. The shelf is heavy enough to make it stable. The new stud is also lon g enough to support the shelf even though the hole was not really in new condition after the old stud was pried out.
Was this helpful?
Thank you for voting!
Freezer Temp was -20 to -30 degrees F. and did not defrost because of the extreme low temperatures.
3 of 4 people found this instruction helpful.
  • George from ENDWELL, NY
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
The Video on U tube was helpful. I have a side by side model and it was difficult to work in such tight quarters to attach the new part . I found that by removing the cable assembly it was much easier to attach (cut and crimp) the new part on the outside , then reinsert the assembly. The new part resolved my problem. Don't panic when you try and remove the cable assembly. Hope this is helpful.
Was this helpful?
Thank you for voting!
Ice maker motor excessive slip (essentially worn out) & contacts were worn
3 of 4 people found this instruction helpful.
  • Richard from Blue Ridge, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
1 removed bottom off old ice maker (3 hex screws) and ice drop shield (white plastic ice flips over into ice holder, old unit had different drop angle, see how described below, but I just musled it off the old unit) 2 removed "ice sensing bar off new ice maker and rotated mechanical sensor to on (leatherman tiny flat head) 3 removed end cap from new ice maker, then loosened to large screws (Phillips, leatherman) for motor unit cover. This allowed removal of ice drop shield on new unit (two tabs, one at each end). 4 removed ice drop shield and installed old ice dropshield on new unit 5 tightened two endcap screws (Phillips/leatherman) and reinstalled end cap 6 installed old bottom unit/tray on new ice maker (3 screws) 7 ensured wiring matched and routed plug properly 8 installed unit slides in 9 plugged unit to existing plug 10 installed old wiring shield (1 hex screw). Waited two hours to verify water valve worked properly, although IR codes did indicate "okay". Machine has been making ice and IR sensor shuts it off properly. So far a success. I have many spare parts if I need to do further repairs including a new water solenoid. Only saying it was a bit difficult because of the parts exchange, in actuality for me it was really easy.
Was this helpful?
Thank you for voting!
freezer section freezing up ( not defrosting )
3 of 4 people found this instruction helpful.
  • John from COLUMBIA, LA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
ordered the parts ,defrost timer and bi-metal thermostat,assumed it would be more practical to replace both than take a chance . watched a video on how to disassemble the control panel and remove the the timer and the back panel of freezer for the bi-metal thermostat,very clear instructions provided .took about 25 minutes to replace both parts and now is working properly again,,Thanks Again PartSelect for the fast service and delivery
Was this helpful?
Thank you for voting!
the light socket broke apart
4 of 7 people found this instruction helpful.
  • Elyse from Skokie, IL
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Was this helpful?
Thank you for voting!
Catastrophic loss of cooling
4 of 8 people found this instruction helpful.
  • Mark from Sugar Land, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
It was straight forward enough--removed six screws from the metal cooling coil shield at the back of the freezer compartment and removed the shield. That left the motor and its mounting exposed atop the coil. Removed the electrical leads and popped out the motor and fan. Then I replaced the leads on the new motor, reset it in the mounting and pushed the fan propeller from the old motor on the spindle of the new. Twenty minutes tops.
Was this helpful?
Thank you for voting!
Evaporator Fan Motor quit working; top shelves of freezer got too warm
2 of 2 people found this instruction helpful.
  • Adrian from REXBURG, ID
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
After viewing online videos of the repair process, it was very easy to replace the evaporator fan motor - just remove the back panel of the freezer compartment for EASY access to the evaporator motor. I received the new motor a day earlier than I thought I would. I took 15 to 20 minutes to replace the old motor. The only problem was th e wiring on the new motor was on the opposite side of the motor as compared with the old motor. I was able to rotate the new motor enough for the new wiring to connect. VERY HAPPY with the results. A word of caution: the motor mounting brackets are plastic - go easy when trying to remove the brackets.
Was this helpful?
Thank you for voting!
Faulty light socket
3 of 5 people found this instruction helpful.
  • Larry from HOUSTON, TX
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
Followed the video instructions.
Was this helpful?
Thank you for voting!
Broken shelf support stud
2 of 2 people found this instruction helpful.
  • Terry from LEHIGHTON, PA
  • Really Easy
  • Less than 15 mins
  • Pliers
Just followed the video supplied with shipment. 5 minutes, even for a mechanically-challenged person.
Was this helpful?
Thank you for voting!
Replacing the bulb in the freezer side
5 of 11 people found this instruction helpful.
  • Yafa (and David) from Bothell, WA
  • Easy
  • Less than 15 mins
  • Nutdriver
Removed the ice brucket,
Removed the light shield by releasing one screw using a nutdriver.
Replacing the bulb and reinstalled the light shield.

Your web site is one of the best and most helpfull service sites I ever used. Just wish that in the future you will ship parts overseas.
Was this helpful?
Thank you for voting!
Cimpressor would not start
5 of 11 people found this instruction helpful.
  • Oliver from Madison, AL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Checked compressor with amp meter, and found it was not running, found Overload Switch bad.
When removing old switch watch carefully which lug you move wires from, so you will know which
lug to put the new switch on.

BE SURE YOU KNOW SOMETHING ABOUT
ELECTRICITY!!
Was this helpful?
Thank you for voting!