Fridge was getting too warm, ice buildup on coils.
159 of 188 people
found this instruction helpful.
-
Cathy from Winter Park, FL
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.
Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ... Read more ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.
Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket
Steps:
1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.
2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.
3: Un-clip the bi-metal strip from the evaporator coils.
4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.
5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.
6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.
7: Do the same for the ends of the wires on the (new) bi-metal strip.
8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.
9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.
10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.
11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.
12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).
13: Replace the panel that covers the coils.
14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ... Read more ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.
Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket
Steps:
1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.
2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.
3: Un-clip the bi-metal strip from the evaporator coils.
4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.
5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.
6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.
7: Do the same for the ends of the wires on the (new) bi-metal strip.
8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.
9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.
10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.
11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.
12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).
13: Replace the panel that covers the coils.
14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Read less
Was this helpful?
Thank you for voting!
Auto Defrost Freezer keeps defrosting SIDE BY SIDE KITCHENAID
38 of 48 people
found this instruction helpful.
-
James from Ringoes, NJ
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
DISCONNECT POWER. Removed all shelves/baskets.Popped upper panel off (just clips in) Removed 6 screws in lower back panel ( 3 each side) slid panel in place but down. You can then easily see the defrost thermostat/defrost termination switch. Cut the wire connectors (pink n brown wire) stripped back wire, attached new defrost thermostat.
... Read more
Thermostat clips on. New thermostat ohm's at 5.5, old one was "open". Slid cover back up meeting the upper cover grooves. Screwed lower panel in. Put shelves etc back in. Plugged in. Turns on, put a bottle of water in freezer. Checked a while later, frozen. has been frozen for a week.
-James
-James
Read less
Was this helpful?
Thank you for voting!
Refrigerator Wasn't Cooling,Evaporater Coil Freezing Up
38 of 50 people
found this instruction helpful.
-
Robert from Doral, FL
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment. The bi-metal switch was right there in plain view. There are two colored wires that come out of
... Read more
the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good
Read less
Was this helpful?
Thank you for voting!
Refrigeator would not drfrost...
27 of 44 people
found this instruction helpful.
-
Curtis from Pikeville, KY
- A Bit Difficult
- 1- 2 hours
-
Pliers, Screw drivers, Socket set, Wrench set
I just removed a few screews and took the cover out of the ice box. Put my voltage meter to the refrigeator and realized the the unit was not defrosting...I then got the part number and entered it in on your web site. A few days later my part arrived. I put the part on and in just about 20 minutes I was up an running again...Thank you
... Read more
Part Select for fast and great service. I own 35 rental properties and having a online appliance parts store really saves me a lot of time and money.
Thank you
Curtis Hall
Thank you
Curtis Hall
Read less
Was this helpful?
Thank you for voting!
Refrigerator No Longer Cooling Properly
15 of 15 people
found this instruction helpful.
-
Elizabeth from DELRAY BEACH, FL
- A Bit Difficult
- More than 2 hours
-
Nutdriver, Screw drivers
Approximately:
1. Unplugged refrigerator.
2. Emptied Freezer.
3. Removed Ice Maker.
4. Waited a few hours for ice to melt around back panel & nuts.
5. Removed back panel and the cover over fan and fan motor.
6. Waited many more hours for ice to thaw over fins, wiring, etc.
7. Easily replaced the bi ... Read more -mental defrost thermostat.
8. Replaced panel, fan cover, ice maker.
9. Plugged in refrigerator and waited a bit.
This worked! Yahoo.
p.s. I am a 65+ year old mechanically minded woman. :-)
1. Unplugged refrigerator.
2. Emptied Freezer.
3. Removed Ice Maker.
4. Waited a few hours for ice to melt around back panel & nuts.
5. Removed back panel and the cover over fan and fan motor.
6. Waited many more hours for ice to thaw over fins, wiring, etc.
7. Easily replaced the bi ... Read more -mental defrost thermostat.
8. Replaced panel, fan cover, ice maker.
9. Plugged in refrigerator and waited a bit.
This worked! Yahoo.
p.s. I am a 65+ year old mechanically minded woman. :-)
Read less
Was this helpful?
Thank you for voting!
It was not coming out of defrost cycle
25 of 45 people
found this instruction helpful.
-
Dale from Flemingsburg, KY
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
First I installed a defrost timer, (the old timer had burnt out contacts in it) It seemed to work for a few days, then went back to not comng out of defrost cycle, I then installed a defrost thermostat. It seems to be working better than before. I found out that maybe I wasn't running it cold enough. So I turned it up colder. Now it
... Read more
works ok for 2 - 3 days, then I check the Temp in the freezer and its up to 6o. So I manually reset the timer and it works for 2 - 3 days. Don't know what to do now to fix it.
Read less
Was this helpful?
Thank you for voting!
THERMOSTAT
9 of 10 people
found this instruction helpful.
-
dominique from COMPTON, CA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
I followed your instructions , the only thing that was left out was that the freezer has a drain hole that had to be thawed out with a hair dryer,till the water went to the drain pan underneath the ref. your instruction were through enough, that's why I purchased the part from your company, I installed the part 2 days ago and its working
... Read more
like new again 23.00 for the part instead of 1200.00 dollars for another ref. thanks very much. 6 months ago I purchased the relay and compressor starter from your company at that time per your instructions I shook the compressor starter and like a light bulb it had something broke inside,I needed that thanks again oomk
Read less
Was this helpful?
Thank you for voting!
Refrigerator and freezer not cooling
5 of 6 people
found this instruction helpful.
-
Tom from FENTON, MO
- Easy
- 30 - 60 mins
-
Pliers
It was easy to replace the start and run capacitors. But did not fix my problem, also replaced the evaporator fan still not fixed. Pulled refrigerator out of RV and ordered a new one.
Was this helpful?
Thank you for voting!
Raise side of fridge and slide 2x4 under side with broken wheel.
5 of 6 people
found this instruction helpful.
-
Hans from OGDEN, UT
- Really Easy
- Less than 15 mins
-
Socket set
Remove back side cardboard access cover. About 6 dcrews need to be removed. Remove 9/16” bolt and lower compressor tray frame down to slide out wheel axel. Place wheel in slot and replace axel. Lift compressor tray and replace 9/16” bolt. Replace cardboard cover. Remove 2x4.
Was this helpful?
Thank you for voting!
fridge stopped cooling then the freezer
4 of 4 people
found this instruction helpful.
-
Joseph from DELTONA, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Searched my issue on the internet then chose part select to see if bi-metal thermostat was available and it was so I ordered part which was under $30.00 incl. shipping. I then went to You Tube to watch how to replace the part but most importantly to find out where it was located and degree of difficulty. Replacement was rather simple and
... Read more
it fixed our 22 year old fridge. I must add that when I looked up the part it also told you what percent of the time that particular item actually fixed the problem based on others experience. I thought that was neat info. as I felt better about ordering something that may or may not fix my problem. Thank you,
Read less
Was this helpful?
Thank you for voting!
Top half of freezer & fridge were not cooling. Freezer fan had been making unusually loud noises.
3 of 3 people
found this instruction helpful.
-
rich from PEMBROKE PNES, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver
Piece of cake. It took me longer to remove the food from the freezer, remove shelves and back panel than to do the repair. I heard the fan making some noises so I replaced both the fan and defrost thermostat. I used the instructions submitted by a another customer. My 20+ year old fridge is like new now.
Was this helpful?
Thank you for voting!
Freezer work perfectly, Refrigerator Stopped getting cold, water line froze, there was ice Forming around the condenser in the bottom of the refrigerator behind the drawers
3 of 3 people
found this instruction helpful.
-
Richard from STATEN ISLAND, NY
- Easy
- 1- 2 hours
-
Nutdriver, Screw drivers
Freezer worked great, refrigerator stopped getting cold and lots of ice formed around the condenser on the bottom of the refrigerator.
First I had a serious ice issue, ice build up around the bottom of the refrigerator and all through the cold air vents, condenser and cooling fan. I unplugged of the fridg and let defrost over night. ... Read more I also took all the cold air vents out and cleaned them.
Then I followed the switch install video very simple switch install. Now the Refrigerator works Great nice and cold.
First I had a serious ice issue, ice build up around the bottom of the refrigerator and all through the cold air vents, condenser and cooling fan. I unplugged of the fridg and let defrost over night. ... Read more I also took all the cold air vents out and cleaned them.
Then I followed the switch install video very simple switch install. Now the Refrigerator works Great nice and cold.
Read less
Was this helpful?
Thank you for voting!
Freezer was icing up and leaking. Refrigerator side would not keep cold.
3 of 3 people
found this instruction helpful.
-
Camille from Glen Ellyn, IL
- Easy
- More than 2 hours
-
Nutdriver, Pliers, Screw drivers
We emptied out both sides, refrigerator and freezer, and followed the instructions in your video. We turned it off and disconnected the power. We took off the freezer door first. It made it much easier to get the shelves out and reach way back into the freezer. We removed the light and cover, then the ice auger motor. The back panel wa
... Read more
s easy to lift and remove. The wire assembly was a little hard to understand at first, but when we figured it out it was easy to remove and replace the bimetal defrost thermostat. We did check the video when we had the wire harness out, to make sure we got it right. We reassembled the freezer's inside parts and reattached the door. Before we turned the power back on, we scrubbed down the entire refrigerator. When we turned the power back on, the refrigerator and freezer were operating quietly - no sparks or explosions or shorting out - hooray! And the problems were solved.
The most important resource is your video. It looked like something we could do, and then ordered the parts. Our repair took a long time because we checked the video so many times. Thank you so much for the great information and the excellent parts. We could not have done it without you.
The most important resource is your video. It looked like something we could do, and then ordered the parts. Our repair took a long time because we checked the video so many times. Thank you so much for the great information and the excellent parts. We could not have done it without you.
Read less
Was this helpful?
Thank you for voting!
Part went bad the freezer was freezing up and refrigerator not getting cold
3 of 3 people
found this instruction helpful.
-
Jessica from WILLIAMSBURG, VA
- Really Easy
- 15 - 30 mins
-
Nutdriver
I pulled off the panel covering the part in the freezer cut and stripped the wires. Used crimper and connectors put the new part on put the wires band panel back on and plugged the refrigerator back in. Everything works just fine now.
Was this helpful?
Thank you for voting!
Freezer Temp was -20 to -30 degrees F. and did not defrost because of the extreme low temperatures.
3 of 4 people
found this instruction helpful.
-
George from ENDWELL, NY
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
The Video on U tube was helpful. I have a side by side model and it was difficult to work in such tight quarters to attach the new part . I found that by removing the cable assembly it was much easier to attach (cut and crimp) the new part on the outside , then reinsert the assembly. The new part resolved my problem. Don't panic when
... Read more
you try and remove the cable assembly. Hope this is helpful.
Read less
Was this helpful?
Thank you for voting!