1066698 Kenmore Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Broken shelf support
9 of 10 people
found this instruction helpful.
-
Arthur from West Chicago, IL
- Really Easy
- Less than 15 mins
snapped in. The best part was the ease that i identified the part due to your website.
Was this helpful?
Thank you for voting!
ice maker, intermittent hollow cubes, then no ice
9 of 11 people
found this instruction helpful.
-
paul from madison, WI
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker ha
... Read more
s been working flawlessly since the repair.
Read less
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people
found this instruction helpful.
-
George from Glenwood, MN
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws
... Read more
and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Read less
Was this helpful?
Thank you for voting!
Ice buildup on the bottom of the freezer, water dripping into the refrigerator
8 of 9 people
found this instruction helpful.
-
Craig from Rockledge, FL
- Easy
- More than 2 hours
-
Nutdriver
After unplugging the refrigerator, I used a hairdryer to melt the ice sufficiently to be able to remove the freezer rear panel with a nutdriver. I also removed the ice-maker for easier access to the components behind the panel, using a nutdriver. Once the panel was removed I melted more ice at the bottom of the evaporator housing. Afte
... Read more
r partially melting the ice in the drain tube, I poured hot water down the drain tube until it cleared, signaled by the sound of the water dripping into the drain pan. I next removed the clip-on Bimetal thermostat from the copper line going into the evaporator and snipped the two wires to remove it. I installed the replacement thermostat with crimp-style connectors and pull-tested them. I also replaced the timer board that is located below the freezer, below the top shelf, using a nutdriver. I replaced the circuit board as a precaution that the thermostat may not have caused the problem. I didn't change the heater inside the freezer as it checked out to have the same resistance as a new one. I tested the removed thermostat using a glass of ice water but it remained in the open condition, using an ohmmeter. (I later checked that thermostat after the freezer was running and it did close, and returned it to the open position by heating it under the hot water faucet. I suspect that it didn't work properly, or the timer control board was faulty). After re-installing the back panel and ice-maker and plugging the refrigerator into the power receptacle, it worked very well, and has done so since the repair.
Read less
Was this helpful?
Thank you for voting!
35 year old water tube became brittle and cracked; leaking water
8 of 10 people
found this instruction helpful.
-
Melvin from OPELIKA, AL
- Very Easy
- Less than 15 mins
-
Screw drivers
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Was this helpful?
Thank you for voting!
The Freezer defrosted and everything on the top and the bottom spoiled
10 of 16 people
found this instruction helpful.
-
Jorge from Miami, FL
- Easy
- 15 - 30 mins
-
Nutdriver
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burn
... Read more
ed. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Read less
Was this helpful?
Thank you for voting!
defrost pan overflowing
15 of 32 people
found this instruction helpful.
-
Rudolf from Lovington, NM
- Really Easy
- 15 - 30 mins
-
Nutdriver
I removed screws to rear cardboard cover. I then removed the condensor fan by unscrewing the nut off the shaft. I then removed 4 screws holding the fan motor. I then replaced the motor and reversed the process.
Was this helpful?
Thank you for voting!
water pump for ice maker would not shut off
7 of 8 people
found this instruction helpful.
-
Lawrence from Clio, MI
- Really Easy
- Less than 15 mins
-
Screw drivers, Wrench (Adjustable)
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires...) Then I put the new valve in, put the cover back on the refridgerator and was done. total time 15 minutes. My wife says I'm the man.
Was this helpful?
Thank you for voting!
light not working in fridge
7 of 8 people
found this instruction helpful.
-
Michael from East Meadow, NY
- Really Easy
- Less than 15 mins
-
Screw drivers
It was so easy!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people
found this instruction helpful.
-
Antonio from San Antonio, TX
- Really Easy
- Less than 15 mins
-
Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
The light was blown
9 of 16 people
found this instruction helpful.
-
Frances from TUNNEL HILL, GA
- Very Easy
- Less than 15 mins
I turned the light bulb into the socket
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people
found this instruction helpful.
-
David from Choctaw, OK
- Easy
- 30 - 60 mins
-
Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin
... Read more
g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Read less
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people
found this instruction helpful.
-
Peter from Herndon, VA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
water leaked when the paddel was pushed
6 of 8 people
found this instruction helpful.
-
Monica from EDMOND, OK
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this helpful?
Thank you for voting!
light bulb in water ice freezer door went bad
8 of 14 people
found this instruction helpful.
-
Carl from RIVERSIDE, CA
- Very Difficult
- More than 2 hours
-
Screw drivers
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this helpful?
Thank you for voting!