Water fill tube broken
3 of 4 people found this instruction helpful.
  • Jeffrey from Monroe, MI
  • Really Easy
  • Less than 15 mins
  • Screw drivers
removed two screws and pulled part out of the unit. The local appliance store said they needed model and part # to try to identify and order the part. Found part select online, found the part immediately, ordered the part for $4.50 or so. Part was delivered in 2 days! Very easy installation and the part works perfectly. Thanks so muc h!
Was this helpful?
Thank you for voting!
lost hinge to door while moving
4 of 7 people found this instruction helpful.
  • Madonna from Washington, NJ
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Just put the hinge on and screwed on
Was this helpful?
Thank you for voting!
Refrigerator quit cooling and the freezer wasn't freezing anything
4 of 7 people found this instruction helpful.
  • Tonya from Grand Prairie, TX
  • Really Easy
  • 15 - 30 mins
  • Socket set
Order the part from the Internet on Sunday, it mailed out on Monday and I received it on Tuesday. I unplugged the fan then undone 3 screws that held the fan bracket to the refrigerator pulled it out unscrewed 3 more nuts and replaced the fan on the bracket and I cut the old wire plug off the old fan and with 2 wire nuts put it on my new f an. Replaced the fan and bracket back on the refrigerator plugged it in and it works like a new refrigerator.
Was this helpful?
Thank you for voting!
the light socket broke apart
4 of 7 people found this instruction helpful.
  • Elyse from Skokie, IL
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Was this helpful?
Thank you for voting!
The water fill tube 90 fitting broke
3 of 4 people found this instruction helpful.
  • Scott from Crete, IL
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Removed brokent tube fitting from the compression nut.
Removed two screws holding the fill tube. Removed and replaced the fill tube. Direct replacement, no cutting tube length. Reconnect water line to the new fill tube.......Done.
Was this helpful?
Thank you for voting!
changed the light bulb still would not work so I figured it was the switch sure enough.
3 of 4 people found this instruction helpful.
  • anthony from HAVELOCK, NC
  • Really Easy
  • 15 - 30 mins
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this helpful?
Thank you for voting!
Cracked Icemaker Water Fill Tube
4 of 7 people found this instruction helpful.
  • James from Ft. Lauderdale, FL
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
The plastic part that connects the fresh cold water to the ice maker in back of the fridge cracked.
Do to the fact that Whirlpool has the part stick out on the back top part of the fridge. So if you push the fridge just an inch too far back the plastic part will crack.
I ordered (The Part S&H)- came to about, $11.00.
... Read more />1. Turned off the cold water under the sink.
2. In the back of the freezer section. I unscrewed the two screws that held the old broken part to the fridge.
3. I opened the freezer section and cleared out the top shelf till I could see the back of the fridge.
4. I removed the old plastic part by pushing & wiggling it about forward and it then extended out the back of the freezer side and then I pulled it out the back and it came out.
5. I slid the new replacement part in basically the reverse of step 4.
6. I connected the hose in the back. To the new, replacement plastic part, that fills the automatic ice tray with water.

7. Once finished I glued a small 2”x2” piece of wood next to the new part so the fridge will never get too close to the back wall so to never break that part that sticks out again.
Before just a small bump could break the part and water is everywhere and this leak could happen slowly at first and the next day what a mess.
Some fridges have this part recessed into the back of the fridge so this would never happen as my other fridge has.
Also, this might seem like more work then it was. It was very simple. I was scared I'd screw it up, but just did it step by step. If I had someone do it. It would have cost me a bundle.
It took more time to type this, then to do the work.
I had no instructions to follow, but again, was easer then I thought it would be.
I hope that this was helpful,
Jim Vourakis
Was this helpful?
Thank you for voting!
Divider front of fridge hot to touch Condenser fan not working
3 of 4 people found this instruction helpful.
  • John from Holden, MA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this helpful?
Thank you for voting!
Fill tube on the icemaker was leaking.Looked at sears repair parts list and part was $62. I found the same part here for $4.99. Very easy to just remove the old part and replace it with the new. I also received the part in two days. Amazing!!!!
3 of 4 people found this instruction helpful.
  • Walton from Woodland, PA
  • Really Easy
  • 15 - 30 mins
  • Pliers
Simlpy removed two screws to remove the old part. replaced the new part and put the two screws in. Job finished.
Was this helpful?
Thank you for voting!
Ice maker motor excessive slip (essentially worn out) & contacts were worn
3 of 4 people found this instruction helpful.
  • Richard from Blue Ridge, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
1 removed bottom off old ice maker (3 hex screws) and ice drop shield (white plastic ice flips over into ice holder, old unit had different drop angle, see how described below, but I just musled it off the old unit) 2 removed "ice sensing bar off new ice maker and rotated mechanical sensor to on (leatherman tiny flat head) 3 removed end cap from new ice maker, then loosened to large screws (Phillips, leatherman) for motor unit cover. This allowed removal of ice drop shield on new unit (two tabs, one at each end). 4 removed ice drop shield and installed old ice dropshield on new unit 5 tightened two endcap screws (Phillips/leatherman) and reinstalled end cap 6 installed old bottom unit/tray on new ice maker (3 screws) 7 ensured wiring matched and routed plug properly 8 installed unit slides in 9 plugged unit to existing plug 10 installed old wiring shield (1 hex screw). Waited two hours to verify water valve worked properly, although IR codes did indicate "okay". Machine has been making ice and IR sensor shuts it off properly. So far a success. I have many spare parts if I need to do further repairs including a new water solenoid. Only saying it was a bit difficult because of the parts exchange, in actuality for me it was really easy.
Was this helpful?
Thank you for voting!
Overload was open
4 of 8 people found this instruction helpful.
  • richard from galena, KS
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
New part was similar, except contact blade was for a full 1/4", my model utilizes 1/8". So I cut the blade in half with a hacksaw, filed off the rough edges and reassemblied the connector; attached it to the compressor
Now being a retired electronic engineer; who's great idea was it to hide a klixon inside the connector?
Was this helpful?
Thank you for voting!
Fan was noisy - bearing had failed
2 of 2 people found this instruction helpful.
  • Karl from Wellesley, MA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
It's self-explanatory. The procedure is obvious; it's just a little difficult. The only hard part is attaching the mounting brackets to the fan. If you can't tighten the mounting bolts, loosen them and reposition the brackets. You might end up mispositioning them at first, because they are hard to reach.
Was this helpful?
Thank you for voting!
Fridge stopped cooling
3 of 5 people found this instruction helpful.
  • ray from palm bay, FL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I replaced the defrost relay folling instructions I read on the internet--and it still didn't work--So I replaced the compressor start relay which was easier than the defrost relay--it worked and the fridg is working good.
Was this helpful?
Thank you for voting!
Bad fan motor
3 of 5 people found this instruction helpful.
  • Mark from Farmington Hills, MI
  • Easy
  • 15 - 30 mins
  • Nutdriver
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.
Was this helpful?
Thank you for voting!
Freezer worked but the refrigerator was not cooling
2 of 2 people found this instruction helpful.
  • Jason from WARWICK, NY
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
Toddler left the fridge door open for an undocumented amount of time. The freezer was operating perfectly but the refrigerator was not cooling. After some research I ordered the part needed and went to work. Process was simple, just keep track of the fans mounting bracket. I installed it upside down and the holes didn't align with the ba ck wall freezer cover.

Step 1: Unplug the fridge
Step 2: Gloves and safety goggles
Step 3: Tools - Socket Set and screw drivers. Hammer and chisel for the ice build up.
Step 4: Remove the back wall of the freezer carefully
Step 5: Remove fan and motor housing, unplug Hot, Neutral and ground wire from motor
Step 6: Drink a beverage
Step 7: Remove fan and motor from housing. You will have to reuse the rubber gaskets/washers so do not dispose.
Step 8: Install new motor and connect the hot, neutral and ground. Do not overtighten the screws connecting the motor housing to the mounting bracket.
Step 9: Before mounting the bracket, plug in the fridge to confirm the fan is operating.
Step 10: Put everything back and have another beverage.
Was this helpful?