EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

1066664 Kenmore - Instructions

All Instructions for the 1066664
1 - 15 of 374

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
My refrigerator stopped cooling and the freezer section stopped freezing
439 of 554 people found this instruction helpful.
  • garth from forest lake, MN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck le t's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
Was this helpful?
Thank you for voting!
Sometimes the condenser fan would start causing the refrigerator to overheat.
184 of 223 people found this instruction helpful.
  • Tom from Franklin, WI
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver, Pliers
Unplug the appliance.
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
Was this helpful?
Thank you for voting!
Broken elbow on icemaker water fill tube.
130 of 142 people found this instruction helpful.
  • Charles from Orland Hills, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Removed 2 screws holding water fill tube to rear of refrigerator and pulled out, matched old part with new to make sure of proper match. Guide new fill tube thru hole, making sure it is aligned with slot in ice cube tray on inside of freezer. Install new plastic line from water pump outlet to water fill tube, check for leaks, job done.
Was this helpful?
Thank you for voting!
Lights inside refrigerator not working
136 of 255 people found this instruction helpful.
  • Clint from Rayville, MO
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Was this helpful?
Thank you for voting!
no water getting to ice maker
80 of 95 people found this instruction helpful.
  • Kevin from Boston, MA
  • Really Easy
  • Less than 15 mins
  • Screw drivers, Wrench (Adjustable)
The ice maker had been slowly dying and one day just stopped making ice. No water was getting to the trays.

I read that this could be caused by a failure of the valve, even though the continuity test indicated that the solenoid was okay.

I ordered the part Friday afternoon. It was delivered Saturday. I did the repai r in 10 minutes.

I pulled the fridge away from the wall.

I unplugged the fridge. I closed the water supply valve.

I unscrewed the two mounting screws using a flat head screwdriver.

I pulled the old valve out from refrigerator.

Using an adjustable wrench I detached the water supply from the valve. I detached the hose leading to the ice maker from the valve.

I pulled the electrical connectors from the connectors on the valve.

I attached the hoses to the new valve, attached the electrical connector, screwed the new valve in its place, opened the water supply, plugged the fridge back in, checked for leaks, and waited for a few hours.

My ice maker is working better than it has in at least two years.
Was this helpful?
Thank you for voting!
Defrost timer was faulty. Required a mild tap to restart
69 of 76 people found this instruction helpful.
  • LES from MADERA, CA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Trouble shot the electrical circuit per the electrical schematic and zeroed in when I noted the Defrost Timer circuit was open. When I tapped on the bottom of the timer it began functioning normally (for a few days). Ordered a new Defrost Timer Kit and along with the installation instruction, I watched the on-line video. It was very help ful!!
After installation was complete, I plugged the Refrigerator into the electrical outlet and.......nothing happened! Hmmm!

Removed the Defrost Time Kit and inspected it for any damage and found none. Then I placed a flathead screwdriver to the manual advance knob and slightly rotate the gear mechanism. I heard a distance "click”. I believe the Timer was in the ‘defrost’ mode when received.

I reinstalled the timer, verified the wiring connections and this time plugged the Refrigerator into the electrical outlet and ….. it worked!!!

I unplugged the refrigerator, finished the installation per the instructions, plugged the unit in and monitored it for a few hours (just in case). That was a week ago and the Refrigerator is working like new.

The instructions were written in a manner which required re-reading a few times as they could be a bit vague. The video was what really helped and I appreciate PartSelect adding it to the instructions.
Was this helpful?
Thank you for voting!
Freezer Iced up, dripping water into refrigerator below
63 of 75 people found this instruction helpful.
  • Robert from Bradenton, FL
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
De-iced the refrigerator. Removed two screws from the thermostat panel on the upper refrigerator section. Tilted it down, removed two speed nuts holding the timer, unplugged the timer plug. Determined from the instruction sheet (easy to follow) what time delay function is used, based on wire colors, placed the jumper on the correct ter minal on the new timer. Plugged it in, replaced the speed nuts and screws. The timer fit perfect, works just like it is supposed to, quick easy job.
Was this helpful?
Thank you for voting!
Light Would Not Go On In The Refrigerator
62 of 82 people found this instruction helpful.
  • DANIEL from MINNEAPOLIS, MN
  • Easy
  • Less than 15 mins
  • Screw drivers
First I removed the old lightbulb from the socket and replaced it with a new one to confirm that the bulb was not the problem. I then pryed the socket out with a flat-head screwdriver. I could tell that the socket was anchored in its hole with clips so it was relatively easy to pry it out. Once the socket was out, I disconnected the le ad wires and ordered a replacement socket kit from Partselect. When the new one arrived, I reconnected the lead wires to it, snapped it back into its hole, screwed in a new lightbulb, and presto!! The light was back on with no further problem. Thank you, Partselect!! A $15.00 part saved me what probably would have been at least a $100. service call and heaven knows what the technician would have told me I needed!!!
Was this helpful?
Thank you for voting!
refrigerator stopped cooling, otherwise fine
48 of 59 people found this instruction helpful.
  • Roger from Bethesda, MD
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Well first of all, I was afraid that the compressor was shot and I'd need a whole new refrigerator (ack $1000!!!). After googling/reading, I figured out that the starter relay mounted on the compressor was burned out. (loud click as thermal cutout shuts down compressor.) So, I ordered a replacement part, overnight shipping. Unfortunately, this was on a Friday night, so I had to figure out how to keep the fridge cold all weekend (til Tuesday). I'd already moved frozen stuff to a chest freezer, but the inside of the fridge compartment was now nearly warm at this point, so I got 10 lb of dry ice. That got things cooled down initially. Well, turns out that with a short piece of wire, you can momentarily jump across the terminals of the relay and kick start the compressor. It then runs until either the defrost cycle stops it or the thermostat kicks it off. Anyway, all weekend, every six hours or so, I turned off the fridge for a minute to cool down the overheated, stalled compressor, then turned it on and jumped the terminals to start it up. Kind of a pain, but saved lots of food. Overall, the $30+$30 (shipping) for the part saved me from having to get a new refrigerator, so I'm quite pleased. I've used Part Select many times now. Very fast service and shipping, great website/database. I shop around and every time end up buying from them again.
Was this helpful?
Thank you for voting!
The freezer section was working fine. Not properly cooling the refrigerator
45 of 52 people found this instruction helpful.
  • Donald from Waco, TX
  • Easy
  • 30 - 60 mins
  • Screw drivers
I looked on line to see what was causes of the problem and determined that it was probably the fan in the freezer not working. I took the back section of the freezer apart and saw the fan was not running. I checked the parts on line and found that it was availiable and ordered a new fan motor. The blade looked fine, but I ordered a gro mmet anyway to ensure that there was no vibration problems causing the fan motor to go out. When the fan motor arrived, I began disconnecting the old one after unpluging the refridgerator and noting the terminals for the wires. The wire terminals were in a slightly different location, but reasoned out which wire belonged to the correct location. I pulled the old fan motor out, switched out the fan blade and grommet and re-incerted the new fan motor. I reconnected the wires and re-assembled the rear wall of the freezer. I plugged in the refridgerator and wa-la! It worked.
Was this helpful?
Thank you for voting!
freezer froze up refridge not cold
39 of 45 people found this instruction helpful.
  • Benjamin from Mahanoy Plane, PA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I unplugged the fridge.Removed the thermostat casing located in the lower part of the refridgerator by removing a few screws. disconnected the wiring plug from the relay board-connected the new board-screwed the new board inplace-put the casing back and replaced those screws. turned fridge back on and HOORAY off we went. i want to add fri nding the part and recieving it so quickly was also part of a great savings to me!
Was this helpful?
Thank you for voting!
Timer "clicking", indicating worn gears
38 of 43 people found this instruction helpful.
  • John from Plano, TX
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
1. Unplug refrigerator to remove power!
2. The timer is inside the control housing located at the top of the refrigerator compartment.
3. Remove two control knobs (the pull off).
4. Remove the front panel escutcheon. The panel is not held in place with screws, but can be gently pried off.
5. Remove two screws from the back that hold the housing in place.
6. Remove screws from the front that hold the housing in place.
7. Drop housing down (still attached by wires - do not detach). Timer is inside housing, located on right.
8. Follow the instructions provided to identify your particular wiring setup. You'll find the wiring diagram (on my model) at the bottom of the refrigerator, alongside the defrost catch pan, behind the airflow grille.
9. Remove connector from timer terminals (4).
10. Remove two screws/nuts that hold the timer in place.
11. Install replacement timer following included directions. Read and follow ALL instructions applicable to your particular model and wiring setup.
12. Reassemble by reversing the steps above.
13. Note: You may need to "jog" the replacement timer when you first plug the refrigerator back in, if the timer happens to be in a "defrost cycle" (the compressor won't start). This can be done by inserting a wide bladed screwdriver into the hole below the timer, aligning it with the timer shaft, and slightly turning the shaft CW. Don't force it, and don't turn it very far.
Was this helpful?
Thank you for voting!
noisy fan motor
38 of 46 people found this instruction helpful.
  • robert from nashotah, WI
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Socket set
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, c lose up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
Was this helpful?
Thank you for voting!
Light Switch broke
48 of 78 people found this instruction helpful.
  • James Richard from St. Cloud, MN
  • Easy
  • Less than 15 mins
  • Socket set
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
Was this helpful?
Thank you for voting!
Freezer wasen't cooling refrigerator
36 of 45 people found this instruction helpful.
  • Joann from ATCHISON, KS
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Removed the old defrost heater screws and connected the new one. I have 46 apartment units here and have had about 15 defrost heater's replaced by service repair person at a very expensive cost. To my surprise it was extremly easy and a lot less in cost.
Was this helpful?
Thank you for voting!
All Instructions for the 1066664
1 - 15 of 374