No ice
567 of 688 people found this instruction helpful.
  • Daniel from Suwanee, GA
  • Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
removed flap door in front of icemaker...removed 3 screws with bolt heads...removed one additional screw with bolt head and ice unit slid out. I removed motor unit (pops out no screws). Replaced and had ice within 3 hours.
Was this helpful?
Thank you for voting!
My refrigerator stopped cooling and the freezer section stopped freezing
441 of 556 people found this instruction helpful.
  • garth from forest lake, MN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck le t's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
Was this helpful?
Thank you for voting!
Seven year old condenser fan was making noise when it was running.
199 of 211 people found this instruction helpful.
  • Josue from Jacksonville, NC
  • Really Easy
  • Less than 15 mins
  • Screw drivers
The process to repair was very simple, I removed the back of the refrigerator to expose the motor area. I then removed three screws that held the condenser motor in place. once it was loose I detactched the electrical harness and removed the old motor. I then placed the new motor in place and secured it with the screws and reattached the new electrical harness that came with the new part. Once completed I reviewed it to make sure I didn't miss anything. I then replaced the cover over the motor area and enjoyed my success in repairing my own appliance with no added cost for labor, which would have been expensive I'm sure. The part purchased came with clear and consice instructions very easy to follow.
Was this helpful?
Thank you for voting!
Evaporator Fan failure
164 of 190 people found this instruction helpful.
  • William from Middletown, NY
  • Easy
  • 15 - 30 mins
  • Nutdriver
The reason I repaired it myself was because the repairman that diagnosed the problem.didn't come back in two weeks. The evaporator fan sits behind a vented wall in the freezer and directs cold air into freezer and refrigerator.I removed the ice make assembly first and then the freezer wall held in place by two sheet metal nuts. Then remov ed wires from fan motor. Removed the fan blade from fan motor,which was press fitted on,then removed fan motor from bracket assembly(make sure and retain the two vibration rubber washers on back and front of motor. Reinstall new motor with vibration washers and press fan blade on new motor. Install in bracket assemble and reassemnble.
Was this helpful?
Thank you for voting!
Fridge was getting too warm, ice buildup on coils.
159 of 188 people found this instruction helpful.
  • Cathy from Winter Park, FL
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Was this helpful?
Thank you for voting!
Ice Maker stopped working
135 of 154 people found this instruction helpful.
  • Robert from Port Washington, NY
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
With socket wrench un-screwed the 3 screws and pulled out the ice maker assembly.

Pulled off white plastic end-cap and noticed the plastic gear disk had snapped off (sub part # R0167202)

However, it is all-one-part of the motor assembly unit # w10190935 (part # PS2341896) which must be ordered as a complete part. ... Read more />
Unscrewed the motor assembly (3 screws) with phillips head screw driver.

Screwed in the new unit.

Placed ice maker back into location and tightend the bacing srews.

1 hour later ice was falling!
Was this helpful?
Thank you for voting!
Broken elbow on icemaker water fill tube.
130 of 142 people found this instruction helpful.
  • Charles from Orland Hills, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Removed 2 screws holding water fill tube to rear of refrigerator and pulled out, matched old part with new to make sure of proper match. Guide new fill tube thru hole, making sure it is aligned with slot in ice cube tray on inside of freezer. Install new plastic line from water pump outlet to water fill tube, check for leaks, job done.
Was this helpful?
Thank you for voting!
Fridge was warm. No air circulating at all. Food was spoiling Fridge was just over 1 year old
107 of 122 people found this instruction helpful.
  • Brian from Smock, PA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
First I removed the two screws that secure the guard in bottom back of the freezer and removed it . Next I removed the two screws that secure the guard on the back wall of the freezer and removed it. There are three wires connected to the motor, I unplugged those and removed the two screws that secure the motor and removed it. I swapped t he grommets, blade and support bracket from the old motor. I put it back together in reverse steps and its working great. My mother-in-law can,t stop thanking me ! I saved her at least $400 to buy a new fridge. Thank You, Brian Miner
Was this helpful?
Thank you for voting!
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
110 of 140 people found this instruction helpful.
  • David from Chester, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
Was this helpful?
Thank you for voting!
Temperature unstable
92 of 114 people found this instruction helpful.
  • Duane from Albany, OR
  • Easy
  • 15 - 30 mins
  • Nutdriver
Open the door. Removed two screws holding the cover of the thermostat. There is a clip which holds the thermostat in place. Remove the clip. Take out the thermostat. Remove the thermocouple (the long grey metal with the coil at the end) which is also held in place by a clip. Replace with the new thermostat and thermocouple and clip i nto place. Replace the screws to the cover. Close the door.
Was this helpful?
Thank you for voting!
Lights inside refrigerator not working
136 of 255 people found this instruction helpful.
  • Clint from Rayville, MO
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Was this helpful?
Thank you for voting!
Drawers were cracked, trim had fallen off.
84 of 102 people found this instruction helpful.
  • Julie from Oak Park, MI
  • Really Easy
  • Less than 15 mins
No need for tools.
Was this helpful?
Thank you for voting!
No water feed to icemaker
81 of 101 people found this instruction helpful.
  • Robert from Abingdon, MD
  • Easy
  • 15 - 30 mins
  • Nutdriver, Wrench set
To troubleshoot - Check water supply to valve. It f that's good - remove back plate, remove water valve reconnect inlet line, disconnect electrical connector, place valve over a pan with outlet fitting disconnected, temporarily connect 110 VAC with clipleads to water valve solenoid. No water flow means valve is not opening. To install ne w valve, connect outlet line, and wiring connector, then insert in cabinet and install 2 screws, reinstall back plate, connect water inlet line.
Was this helpful?
Thank you for voting!
Icemaker made a clicking noise then quit making ice
77 of 96 people found this instruction helpful.
  • Ryan from Layton, UT
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Motor from Part Select was 185W instead of 260W that came out of unit. After a bit of searching online, I found out the 260W had been obsoleted for lack of torque when harvesting ice.

Removal instructions: Unplugged fridge. Then I removed the screw on the bottom right rear of the unit. Then removed the plastic cover that covered the power connector. Pulled out the icemaker by pushing in the tab on the bottom left middle of the icemaker unit and pulling unit toward me. Unplugged the connector on the back right hand side. Removed the cover on the left side covering motor. Took out 3 philips screws and removed old motor with broken axle that spun freely (the source of the clicking noise). Put new motor in aligning harvest arm (the thing with the fingers) and did reverse of removal. Then plugged fridge back in and it started a harvest and the next morning I had a half tub of ice.
Was this helpful?
Thank you for voting!
No ice in ice trey
79 of 104 people found this instruction helpful.
  • Wayne from Leesburg, FL
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
The easiest thing to do was pull the ice make off. After taking the 3 screws out of the wall of the freezer, take a screwdriver (flathead) and push on the tab for the electrical plug and wiggle the cord out. Then you can take 3 screws out for the main cover and another 2 screws on the next cover. There's the part, pop it out and replace h olding pins and start the process of putting back together the opposite way you took it apart.