Freezer icing up
8 of 12 people found this instruction helpful.
  • phil from sioux falls, SD
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Freezer was running for extremely long periods I noticed and not doing a great job of cooling the fridge.I assumed it was in need of a defrosting so I took the panel off to take a look.
The whole radiator was covered with ice.I could see the defrost thermostat was half way popped out of its casing at a 45 degree angle.
I just ha d to cut the 2 wires to the defrost thermostat and wire nut the new one in.Very easy fix as the part just clips on radiator.
Was this helpful?
Thank you for voting!
The old motor has built in wire harness. The new motor has connectors on it.
6 of 6 people found this instruction helpful.
  • Leo from EAGLE, WI
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Remove and clean out everything from the freezer and unplug the refrigerator. Take out the wire shelf in the freezer. (The fan motor is behind the back wall of the freezer, SO YOU CAN KEEP THE REFRIGERATOR CLOSED). Pop off the little cover on the center of the plastic shroud. Remove the little screw and carefully remove the plastic shroud . Remove the plastic cover for the optional ice maker on the upper left corner of the back wall. Take out the two screws in the upper corners on the back wall of the freezer and the last two screws holding the fan motor. The fan motor won't drop, remove the back wall and you will see two screws holding the motor mount. Remover those two screws, and pop the bracket out and separate.Take the two rubber motor mounts off the ends of the old motor and install them on the new motor. (Now you will have to cut the wires off the old motor), unplug the little wire harness, strip the ends and crimp on wire connectors to plug them onto your new motor. Its an AC motor so it shouldn't matter which hot goes on which of the two terminals. JUST MAKE SURE THE GROUND IS CORRECT! (After reinstalling the motor, plug in the refrigerator, turn it on before installing the shroud and make sure the fan is blowing outward. If all is correct, turn the refrigerator off, unplug and finish assembling the freezer. I found the new motor seems to run more efficiently than the old one.
Was this helpful?
Thank you for voting!
Refrigerator would not cool down. Evaporator fan inop.
6 of 7 people found this instruction helpful.
  • David from SHARPSBURG, GA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Unplug, then remove shelving and rear panel. Remove fan motor, swap wired and install new motor. Reinstall in reverse order. Plug back in and verify the fan is running. Easy and nothing special. Only thing I would caution is they use a foam runner to the refrigerator that may be iced up. Carefully clean the ice out before reinstalling eve rything. A follow up note. If the fan has not been running, Ice will build up in the drain tube. When you start up the refrigerator, you will see water dripping into the lower shelf. This is easy to fix. Unplug refrigerator and disassemble to where you can see the coils. There will be ice on the bottom covering the drain line hole. You will need to carefully chip away the ice, then use a hair dryer to melt the ice. Carefully use a pointed tool to push in the drain tube until the water drains. Go slow and be patient. Heat is your friend when doing this.
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people found this instruction helpful.
  • Antonio from San Antonio, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
Ice maker broken
6 of 7 people found this instruction helpful.
  • Gloria from Folsom, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I had already removed the old Ice maker, so it was no longer in.

When the new ice maker arrived, I simply pluged it in, replaced the screws that hold it in place and turned the water back on to the ice maker.
It was that easy.
Was this helpful?
Thank you for voting!
Refrigerator had shut down
7 of 11 people found this instruction helpful.
  • Ronald from Martinsville, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Was this helpful?
Thank you for voting!
ice tray was leaking water
5 of 5 people found this instruction helpful.
  • Brenda from Henderson, NV
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Unplugged wire, loosened two screws on top took out lower screw.Lifted the ice maker up and out it came. The wiring that came with the new part was to short so we unplugged ours from the old part and used it:) was really easy and works great now no leaks
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people found this instruction helpful.
  • Duncan from Metairie, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?
Thank you for voting!
The tray evaporator developed a leak due to rust.
8 of 14 people found this instruction helpful.
  • Matthew from Iselin, NJ
  • Easy
  • 15 - 30 mins
  • Wrench set
Using the parts list that came with the refrigerator, I ordered the exact replacement part. First I removed the single nut that holds the tray onto the top of the compressor with a standard wrench. Then I carefully removed the pan filled with condensate taking care not to damage the coils. I then inspected the area and wiped off the di rt. I inserted the new evaporator tray carefully into position. The tricky part was starting the nut that secures the pan because of the confined space that I had to work in. Long fingers worked the best. After 3 attempts I was able to start the nut, and then I finished it off by tightening with the wrench. It is best to keep the parts list that comes with your appliances.
Was this helpful?
Thank you for voting!
fridge ouit cooling
9 of 17 people found this instruction helpful.
  • danny from adelanto, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
where the wires crossed at the start relay, 20 years of vibration allowed them to short out and burn out the start relay ..since i have 2 identical fridges i switched the run capacitor to determine it was'nt bad too...ordered a start relay wednesday nite and got it friday morning...cold fridge by noon...good service and the part was exact ly the same as the original....
Was this helpful?
Thank you for voting!
the ice maker quit producing ice.
5 of 5 people found this instruction helpful.
  • darryl from little york, IL
  • Easy
  • 30 - 60 mins
  • Nutdriver
I removed 1 bottom screw and 2 upper screws useing a 1/4 inch socket nut driver. then useing a flat edge screwdriver i incerted in slot to remove wiring cluster. to install just reverse process. you maye have to cut u-shape slot for water spout to sit in.
Was this helpful?
Thank you for voting!
Freezer would periodically allow things to partially thaw out
5 of 6 people found this instruction helpful.
  • Dana from Canyon Lake, TX
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Socket set
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!
Was this helpful?
Thank you for voting!
Freezer was dripping water into refrigerator below
5 of 6 people found this instruction helpful.
  • John from Redmond, WA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Removed the old timer from the housing. The replacement came with good instructions. I followed the instructions corresponding to the color wires in my unit. The first time it was installed, the fridge did not come on and the temperature rose after a couple hours. Looked at the part and realized the defrost cycle must have kicked in. Need ed to slightly turn the gray slotted part to initiate the timer so it would stop the defrost and start the fridge. That did it! It must have advanced the timer so it could accumulate run time. Whole repair saved us $3000 in a new fridge.
Was this helpful?
Thank you for voting!
Raise side of fridge and slide 2x4 under side with broken wheel.
5 of 6 people found this instruction helpful.
  • Hans from OGDEN, UT
  • Really Easy
  • Less than 15 mins
  • Socket set
Remove back side cardboard access cover. About 6 dcrews need to be removed. Remove 9/16” bolt and lower compressor tray frame down to slide out wheel axel. Place wheel in slot and replace axel. Lift compressor tray and replace 9/16” bolt. Replace cardboard cover. Remove 2x4.
Was this helpful?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
6 of 9 people found this instruction helpful.
  • Wayne from Arlington, TX
  • A Bit Difficult
  • Less than 15 mins
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causin g the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Was this helpful?
Thank you for voting!