EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

1013 - Instructions

All Instructions for the 1013
1 - 14 of 14

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
bad element control switch
12 of 16 people found this instruction helpful.
  • Richard from Beverly Hills, CA
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers, Wrench set
1. Turn off power to range at circuit breaker
2. Remove grate
3 Remove control knobs
4, Remove two screws holding control panel
5. With wrench, remove locking nuts from control switches
6. Lift panel, exposing switches
7. With new switch in hand, unattach old switch one terminal at a time, attaching new swi tch exactly as old switch, terminal by terminal.
8. Replace everything in reverse order
9.Turn on power
Was this helpful?
Thank you for voting!
Broken exhaust vent cover.
12 of 17 people found this instruction helpful.
  • Richard from Sacramento, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Just removed the broken vent cover.
Injected foaming sealant.
Pushed on the vent cover plate.
Screwed it in place.
More foaming sealant.
Clipped on the flapper and secured the cover.
Was this helpful?
Thank you for voting!
Motor bearing failure after 34 years.
9 of 9 people found this instruction helpful.
  • Wade from CARMINE, TX
  • Really Easy
  • 1- 2 hours
  • Nutdriver, Screw drivers
Important: Down load the helpful assembly diagram for the fan motor and study it for a few minutes. It's very straight forward. Also a good idea is to remove the bottom panel which comes off easy before starting.

My only problem was removing the existing blower/fan wheel without damaging it once I had the assembly on the work b ench. It was rusted on tight and managed to remove after a few tries using penetrating oil. The wheel is in stock and I'd suggest buying a new one along with the new motor if I had to do the job again.

Bottom line; the fan motor fit perfect but did have to re-use part of the old existing electric pig tail because the motor does not come with the factory type motor terminal connectors. By using three twist on wire connectors was back in business. The down draft vent works like new.

Wife is happy...

Wade
Was this helpful?
Thank you for voting!
Didn't like the appearance of a cheap-looking dryer vent on an exposed area of my new house.
7 of 8 people found this instruction helpful.
  • Robert from Jacksonville, AL
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
I enlarged the vent access hole from four (4) inches to five (5) inches to accomodate a larger pipe. I then purchased locally a 5" to 4" transition and installed it in the enlarged opening, and sealed the space with expanding foam for a bug-proof air-tight fit. On the inside of the house I attached a short length of 4" pipe to attach th e dryer vent pipe. On the outside, in the place of the aluminum vent cap, I installed the 5" Jenn-Aire vent cover purchased from PartSelect.com. The new vent is large enough to completely cover the chiseled out masonry area, and the 5" outlet reduces air noise from the dryer, but best of all the new vent provides the high quality look I needed to match the brick of my new home.
Was this helpful?
Thank you for voting!
Dry rotted rubber
7 of 12 people found this instruction helpful.
  • James from PICAYUNE, MS
  • Very Easy
  • Less than 15 mins
Put some dish soap on the rubber, push into the tank hole, slip 1x2 into the handle of the tank and over the new part and pry down pushing it into the hole. Took about 2 minutes.
Was this helpful?
Thank you for voting!
Wall vent cap & damper were broken.
5 of 7 people found this instruction helpful.
  • Jim from Sulphur, OK
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Attached spring to damper, placed on existing 5" duct and secured. Used screwdriver to attach vent cover to damper.
Was this helpful?
Thank you for voting!
broken vent cap
3 of 3 people found this instruction helpful.
  • Robert from Shaker Hts, OH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Unscrewed old cap, installed new
Was this helpful?
Thank you for voting!
old valve dripped gas when opened on cold sub zero day
4 of 6 people found this instruction helpful.
  • Alan from RADFORD, VA
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers
old valve easily pulled out with screwdriver and pliers

install difficult due to 40 degree cold temp and bushing didn't want to squeeze into fuel tank hole

install required lots of liquid soap on bushing, which popped into place by using upward prying pressure from 3"X24" plywood braced into under-shelf of gas tank