My 13 yr grandson assisted me on this
15 of 18 people
found this instruction helpful.
-
Sherry from Auburn Hills, MI
- Really Easy
- Less than 15 mins
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Was this helpful?
Thank you for voting!
Iced up Freezer compartment in SxS
15 of 18 people
found this instruction helpful.
-
Jamison from Heltonville, IN
- Really Easy
- Less than 15 mins
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice m
... Read more
aker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Read less
Was this helpful?
Thank you for voting!
No longer needed water filters
22 of 39 people
found this instruction helpful.
-
Jeffrey from Williamsburg, VA
- Really Easy
- Less than 15 mins
Your website was very easy to use and the product shipped very promptly. It was great experience. Thanks!
Was this helpful?
Thank you for voting!
freezer fan failing; veried speed making whirling sounds
14 of 16 people
found this instruction helpful.
-
Jason` from Colchester, CT
- Easy
- 1- 2 hours
-
Nutdriver
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that
... Read more
held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
Read less
Was this helpful?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
19 of 33 people
found this instruction helpful.
-
Terry from Simi Valley, CA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring s
... Read more
o it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Read less
Was this helpful?
Thank you for voting!
Loud knocking noise with the evaporator fan
13 of 15 people
found this instruction helpful.
-
lk from carlsbad, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).
I wasn't so sure all that noise would come from the Evaporator Fan mot ... Read more or so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
I wasn't so sure all that noise would come from the Evaporator Fan mot ... Read more or so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
Read less
Was this helpful?
Thank you for voting!
Existing light switch was hard to remove.
14 of 19 people
found this instruction helpful.
-
Stephen from Jupiter, FL
- A Bit Difficult
- Less than 15 mins
-
Screw drivers
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this helpful?
Thank you for voting!
Broken freezer light switch
14 of 20 people
found this instruction helpful.
-
James from Goshen, KY
- Really Easy
- 15 - 30 mins
-
Screw drivers
Part arrived very fast as ordered..need to pry old switch out from top..use care to push the retainer down..after old switch was 1/2 out, I used a putty knife for better leveridge.Remove wire connector...after plugging in the wire connector to the replacement switch, make sure the switch is properly positioned so the switch will depress w
... Read more
hen door shuts.
Read less
Was this helpful?
Thank you for voting!
Flapper was stuck open. Old and warped.
16 of 27 people
found this instruction helpful.
-
James from Virginia Beach, VA
- Easy
- 15 - 30 mins
-
Screw drivers
Replaced flapper
Was this helpful?
Thank you for voting!
slow water flow in dispenser
14 of 21 people
found this instruction helpful.
-
dwight from phoenix, AZ
- Really Easy
- Less than 15 mins
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
Was this helpful?
Thank you for voting!
filter replacement/water tray replace
12 of 16 people
found this instruction helpful.
-
ron from Winter Haven, FL
- Really Easy
- Less than 15 mins
-
Screw drivers
remove by hand turning old and replacing new by turning by hand.Lifted out old grill and placed in new one
Other Parts Used:
Was this helpful?
Thank you for voting!
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
16 of 28 people
found this instruction helpful.
-
Laura from Manchester, NH
- Really Easy
- 15 - 30 mins
-
Screw drivers
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this helpful?
Thank you for voting!
Ice funnel cracked
18 of 34 people
found this instruction helpful.
-
Jim from Glendale, AZ
- Easy
- 15 - 30 mins
-
Screw drivers
Followed video for replacing the ice chute flap solenoid replacement because getting to the ice funnel took same steps of disassemble. Looked at how the existing funnel was set in the housing, where and how one spring was located, where the switch and its activating arm on the ice funnel were located, took old one out and put new one in.
... Read more
Cleaned everything in process.
Read less
Was this helpful?
Thank you for voting!
The unit will not dispense water, but does make and dispence ice.
16 of 29 people
found this instruction helpful.
-
michael from west bend, WI
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
I replaced that part, but I still have the same problem, no water is dispensed. I believe I may need a circuit board. The problem was not the parts I replaced.
Other Parts Used:
Was this helpful?
Thank you for voting!
refrigerator and freezer stopped working
9 of 9 people
found this instruction helpful.
-
mike from Aguilar, CO
- Really Easy
- 30 - 60 mins
-
Nutdriver
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what
... Read more
the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Read less
Was this helpful?