- Home
- ZSC2201J1SS
- Instructions
ZSC2201J1SS (2015) General Electric Range - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Oven wouldn't sensor reheat & error code on display
8 of 11 people
found this instruction helpful.
-
Chris from Springfield, VA
- Easy
- 15 - 30 mins
-
Screw drivers
I looked at the exploded pic on your web site to find the location of the sensor. Next I removed the cover by unscrewing 15 screws then swaped the sensor and re assembled! Works great! Fixing it my self I saved at least 150$ and did not have to wait all day for a repair man who probaly would not have the part on the first visit.
Was this helpful?
Thank you for voting!
Sparking from the magnetron
5 of 5 people
found this instruction helpful.
-
Reid from LITTLETON, CO
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
Symptom: Terrible sparking coming from the right side of the microwave even with nothing in the microwave. The part that was behind the cover was the business end of what I learned was the magnetron,
Repair process: Without appliance repair experience I went onto Google and searched for parts for my model PEB1590DM2WW. I ... Read more was able to find a great parts schematic on partselect.com. At first I ordered a magnetron and while waiting for the parts to arrive I also learned that the capacitor can also fail easily as described in the other install feedback on the partsselect website. So I ordered a capacitor just in case. These convection microwaves are around $600 new so a $80 in parts is not out of line for 8 years of service.
I installed the magnetron first and turned it on. sparking immediately continued so I quickly shut the unit off. After replacing the capacitor and letting it charge for several minutes before trying to start the microwave cycle was the issue. I choose to leave the replaced magnetron as the original unit was discolored and felt the replacement was inexpensive insurance. I also learned that if the wave guide (which is a plastic/metallic composite material) that covers the opening to the magnetron is burnt or has metal melted to it as mine did it will act similar to the microwave having metal inside the enclosure and will continue to spark and basically melt the wave guide further. Replacing the wave guide was very easy as well.
I am very thankful for the knowledge base and support available from Partselect.com as they made this repair possible on my own. Thank you partselect.com
Repair process: Without appliance repair experience I went onto Google and searched for parts for my model PEB1590DM2WW. I ... Read more was able to find a great parts schematic on partselect.com. At first I ordered a magnetron and while waiting for the parts to arrive I also learned that the capacitor can also fail easily as described in the other install feedback on the partsselect website. So I ordered a capacitor just in case. These convection microwaves are around $600 new so a $80 in parts is not out of line for 8 years of service.
I installed the magnetron first and turned it on. sparking immediately continued so I quickly shut the unit off. After replacing the capacitor and letting it charge for several minutes before trying to start the microwave cycle was the issue. I choose to leave the replaced magnetron as the original unit was discolored and felt the replacement was inexpensive insurance. I also learned that if the wave guide (which is a plastic/metallic composite material) that covers the opening to the magnetron is burnt or has metal melted to it as mine did it will act similar to the microwave having metal inside the enclosure and will continue to spark and basically melt the wave guide further. Replacing the wave guide was very easy as well.
I am very thankful for the knowledge base and support available from Partselect.com as they made this repair possible on my own. Thank you partselect.com
Read less
Was this helpful?
Thank you for voting!
Microwave bulb was burnt out
7 of 12 people
found this instruction helpful.
-
Sharry from Lititz, PA
- Really Easy
- Less than 15 mins
-
Screw drivers
It is easy to repair the burnt out bulb if one has the correct bulb. Your website is very user friendly and your service is great. I was not able to replace the bulb at this time because our RV is at the repair shop for some other matters. I am sure the installation of the new bulb will go smoothly. Thanks for asking. Sharry Kiehl
Was this helpful?
Thank you for voting!
runs but does not heat
4 of 4 people
found this instruction helpful.
-
Scott from PIEDMONT, CA
- Easy
- 15 - 30 mins
-
Screw drivers
I removed the main cover ( torx security bit required) and tested the magnetron, capacitor, diode and door interlock switches according to instructions found on the internet. The capacitor and diode tested good but the magnetron looked burnt and corroded on the tip. The magnetron I received was an exact replacement for the original. It wa
... Read more
s easy to replace the magnetron which arrived in 2 days standard shipping. I also cleaned the fan while I had access to the inside area. Hoping to get another 18 years use from the microwave!
Read less
Was this helpful?
Thank you for voting!
Replaced under hood surface light bulb
4 of 5 people
found this instruction helpful.
-
Dottie from NEW MILFORD, CT
- Very Easy
- Less than 15 mins
-
Screw drivers
Very easy to replace. This replacement part is the perfect fit for my microwave since the original part has been discontinued. It does have the night light and bright light feature.
Was this helpful?
Thank you for voting!
Frost build up on bottom to ice bin and delivery chute in door creating ice blockage
3 of 5 people
found this instruction helpful.
-
Ronald from PONCA CITY, OK
- Really Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Remove the ice bin.
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of t ... Read more he freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of t ... Read more he freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Read less
Was this helpful?
Thank you for voting!
the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
2 of 3 people
found this instruction helpful.
-
James C from ARLINGTON, TX
- Easy
- 15 - 30 mins
-
Screw drivers
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent openi
... Read more
ng to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
Read less
Was this helpful?
Thank you for voting!
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
1 person
found this instruction helpful.
-
Pearlie from Beulaville, NC
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followe
... Read more
d them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
Read less
Was this helpful?
Thank you for voting!
Not heat
1 person
found this instruction helpful.
-
Kip from POWELL, OH
- Very Easy
- 15 - 30 mins
-
Screw drivers, Socket set
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Was this helpful?
Thank you for voting!
Burned out magnetron
1 person
found this instruction helpful.
-
Dewey from MADISON, AL
- Very Easy
- 15 - 30 mins
-
Screw drivers
Removed cover
Disconnected capacitor from old magnetron
Removed old magnetron
Installed new part
Connected capacitor
Reinstalled cover
Disconnected capacitor from old magnetron
Removed old magnetron
Installed new part
Connected capacitor
Reinstalled cover
Was this helpful?
Thank you for voting!
Bulb burnt out
1 person
found this instruction helpful.
-
DEBORAH from SUMMERTON, SC
- Very Easy
- Less than 15 mins
Followed instructions that came with bulb I ordered and could not have been easier. Will use this site again.
Was this helpful?
Thank you for voting!
Try to heat food and fuse would blow.
8 of 22 people
found this instruction helpful.
-
bart from new sarpy, LA
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
Went on Youtube and pulled up how to fix a microwave.
Was this helpful?
Thank you for voting!
Thermostat quit.
1 of 2 people
found this instruction helpful.
-
Tony from ITHACA, MI
- Easy
- Less than 15 mins
-
Screw drivers
Checked all sensors with a multi-meter, found the thermostat to be the problem, no continuity.
Was this helpful?
Thank you for voting!
No problem. Rollers on guide had worn out.
1 of 2 people
found this instruction helpful.
-
Maeta from CLOVERDALE, CA
- Very Easy
- Less than 15 mins
Just put it in place in you Advantium and place your glass tray on it and you’re ready to roll
Was this helpful?
Thank you for voting!
Replace bulb under microwave
2 of 5 people
found this instruction helpful.
-
Andrew from COLUMBIA, MD
- A Bit Difficult
- Less than 15 mins
-
Screw drivers
Part Select sent the wrong part I did not realize it until prong broke off one of the bulbs. They sent 130v instead of 120v. Return bulbs awaiting resolution.
Was this helpful?
Thank you for voting!