water was dripping in freezer (ice maker)
5 of 5 people
found this instruction helpful.
-
Gerda from RIO RANCHO, NM
- Very Easy
- Less than 15 mins
-
Nutdriver, Wrench (Adjustable)
We actually followed the instructions of the video for the installation of the dual inlet valve and it was incredibly easy to perform. The fridge works perfect again!
Was this helpful?
Thank you for voting!
light not working
7 of 11 people
found this instruction helpful.
-
robert from FRANKLIN SQ, NY
- Very Easy
- Less than 15 mins
-
Pliers, Screw drivers
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Was this helpful?
Thank you for voting!
union connector leaking
7 of 11 people
found this instruction helpful.
-
Amy from Bryan, TX
- Really Easy
- 15 - 30 mins
-
Pliers
replaced with new connector and it worked great. also replaced the water filter and that was super easy!
Other Parts Used:
Was this helpful?
Thank you for voting!
No water from the dispenser
5 of 5 people
found this instruction helpful.
-
Anthony from Carmel, IN
- Really Easy
- 15 - 30 mins
-
Screw drivers, Wrench (Adjustable)
I pulled-out & unplugged the refrigerator. Removed the screws to gain access through the lower back panel. The water valve is on the left side as I face the back of the fridge. It has one screw holding it to the frame of the fridge. Once it is free, the main water hose is unscrewed and the two out-let lines were pulled-out. If your v
... Read more
alve was not ruined prior to this, it is ruined now, as the lines will not re-seat. Then everything is done in reverse order. I did cut 1/2 inch off of the two lines so that they reseat into the new valve. Just push into the valve and they are good.
Read less
Was this helpful?
Thank you for voting!
Cold water for door - leaked on floor
5 of 5 people
found this instruction helpful.
-
JOSEPH from SURFSIDE, FL
- Easy
- 30 - 60 mins
Pulled new tubing to the tank and put a union about 8 inches down from tank to new tubing. Great repair. Parts not readily available locally.
Other Parts Used:
Was this helpful?
Thank you for voting!
Ice maker inlet tube was freezing up, and eventually the icemaker overfilled and completely froze up
5 of 5 people
found this instruction helpful.
-
Jake from Brainerd, MN
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers, Wrench (Adjustable)
After lots of research online, i narrowed my problem down to be the double outlet water valve, behind the fridge. My biggest problem was getting the refridgerator out of its spot, but after that it was pretty simple to change. I took the cover off the bottom, in the back of the fridge, then i removed the inlet waterline (after i turned
... Read more
off the water supply to the fridge). After that i removed the screw that holds the valve to the framework. Now i pulled off the two other waterlines from the old valve and moved them, one at a time, over to the new valve, along with the wire harness. The rest of the instalation was reverse order. Simple fix that im glad i didn't pay an expert to do!
Read less
Was this helpful?
Thank you for voting!
Noisey evap motor
7 of 11 people
found this instruction helpful.
-
Peter from Kalispell, MT
- Easy
- 30 - 60 mins
-
Nutdriver
I tried to quite the noisey evap motor with special liquid motor grease from Radio Shack. It did not work, so I ordered the evap motor. My freezer motor was wired slightly different than the motor I received. The replacement motor had a male plug attached to the four wires, the original motor was different, so I cut the wires and splic
... Read more
ed them into the original freezer wires (colors were the same). Remounted motor. Works great, and no more groaning motor
Peter
Peter
Read less
Was this helpful?
Thank you for voting!
Water reservoir for in door water dispenser had a crack and started leaking
5 of 5 people
found this instruction helpful.
-
James from PALMETTO BAY, FL
- Really Easy
- 30 - 60 mins
-
Screw drivers
Removed all shelves including slide racks.
Removed back panels to expose the tank.
The new tank came with long tubing that could of been routed down/under to the connection points outside the box. However I used 5/16 push/compression fittings and just spliced the tubes right at the reservoir. Easy.
Removed back panels to expose the tank.
The new tank came with long tubing that could of been routed down/under to the connection points outside the box. However I used 5/16 push/compression fittings and just spliced the tubes right at the reservoir. Easy.
Was this helpful?
Thank you for voting!
Unit had stopped making ice
5 of 5 people
found this instruction helpful.
-
Ron from ORANGE, CA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Was this helpful?
Thank you for voting!
The grill flew off going down the freeway.
7 of 11 people
found this instruction helpful.
-
Mark from Ramona, CA
- Really Easy
- 1- 2 hours
I took the part out of the package and placed it in the recessed water dispenser/ice maker cavity. Done!
Was this helpful?
Thank you for voting!
Noisy refrigerator
6 of 8 people
found this instruction helpful.
-
Eric from NEW YORK, NY
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the gromme
... Read more
t facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
Read less
Was this helpful?
Thank you for voting!
Ice maker door didn't open and close properly
5 of 6 people
found this instruction helpful.
-
M Alan from Lebanon, TN
- Really Easy
- 15 - 30 mins
-
Screw drivers
I removed the outer plate by sticking a very small screwdriver in the small holes at the bottom of the plate and pulling the plate toward me.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid ... Read more in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid ... Read more in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
Read less
Was this helpful?
Thank you for voting!
Water not dispensing
5 of 6 people
found this instruction helpful.
-
Bob J from Platte City, MO
- Really Easy
- 15 - 30 mins
-
Nutdriver
Background: My refrigerator was part of the class action law suit back in 2006. As a result both doors, the auger in the ice maker and a heating element in the freezer were all replaced.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the ... Read more refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the ... Read more refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Read less
Was this helpful?
Thank you for voting!
Frost In Frezer Compartment Where Chute Meets Ice Cube Maker
10 of 21 people
found this instruction helpful.
-
Anthony from Miramar Beach, FL
- Easy
- 15 - 30 mins
-
Screw drivers
Removed front panel (using small screw driver) by popping it out, disconnected wire from solenoid, removed solenoid which was rusted, 3 small philip head screws held it in place insereted new solenoid,connected wire snapped front panel back in. Clapper valve closes tightly and no frost in frezzer, saved my self a bunch of money.
Other Parts Used:
Was this helpful?
Thank you for voting!
Was not getting water to the door.
5 of 6 people
found this instruction helpful.
-
nancy from Mt. Washington, KY
- Easy
- 15 - 30 mins
-
Nutdriver, Wrench set
Moved refrigerator out from wall, unplugged from electric, removed plate at bottom back with 1/4 nut driver, turned incoming water valve off, disconnected water line from water valve on refrigerator, removed mounting screw, remove water lines from valve and electrical plugs, set old valve aside and replace with new valve, reconnecting wa
... Read more
ter lines and electrical plugs then remount bracket, reconnect water line from source, open water valve and check for leaks, replugged refrigerator and depressed the door button to check to see if working. It worked and there was not any leaks. Replaced back plate and placed refrigerator against wall. Job completed.
Read less
Was this helpful?