The control board generated clicking noise. Temperature display wrong values.
1 of 2 people found this instruction helpful.
  • QUOC-LOC from LYNN HAVEN, FL
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
P lugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
Was this helpful?
Thank you for voting!
Refrigerator and freezer drawer would not maintain set temperature
  • James from Bel Air, MD
  • A Bit Difficult
  • 30 - 60 mins
  • Socket set
Condenser fan motor was running slow. This was not a problem included in your list of possible problems. I thought that maybe the capacitor was bad but have no way to check it. So I ordered one. when I received it, I installed it. That was not the problem. So I ordered a fan motor and installed it. That was not the problem. So finally I o rdered a control board and installed it. That solved the problem. So maybe you should put "cond.fan motor runs slow" in your list of possible faults and what causes that problem. Capacitor was easy to install, simply remove the cover plate, flip off retaining wire, unplug the capacitor and replace. Fan motor was a bit more difficult. It must be removed from mount after fan scroll is removed. Remove one screw that holds scroll, bend the top down and remove. Then pull hard on fan blade to remove it. It must be installed on new motor. Two screws in frame mount can be removed with some effort if you have a 1/4" drive ratchet with a Phillips screwdriver bit. Then pull frame open and install new motor. Push fan blade on new motor shaft hard. Replacing control board was easy. I used a pair of long nose pliers with 90 degree bend to get mounting pins closed to pull board off.
Was this helpful?
Thank you for voting!
water dispensed slow and filters too expensive and not very reliable
  • john from selbyville, DE
  • Really Easy
  • Less than 15 mins
I just unscrewed filter and screwed in filter bypass
Was this helpful?
Thank you for voting!
Freezer And Frig Both Warm And Compressor Would Not Run
  • joe from decatur, GA
  • Easy
  • 15 - 30 mins
  • Screw drivers, Wrench (Adjustable)
I replaced the thermostat, temperature sensor, and the run capacitor. . . Refrigerator still not cooling. I checked the start relay and measured the input terminals on the compressor for the correct resistance. . . Everything measured correctly. In a last ditch effort before calling for service, I pulled the main board, inspected it and saw the problem right away. One leg on the compression capacitor had desoldered itself. Got out my soldering iron and applied a good amount of solder to that point. Put everything back together and turn it on. . . Problem fixed. The compressor kicked on right away and started cooling the refrigerator.
Was this helpful?
Thank you for voting!
Starter/overload assembly and run capacitor were bad
  • Colby from Blanding, UT
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Removed rer cover, unplugged starter assembly from side of compressor and replaced unit with a new one. Plugged fridge in and it works good.
Was this helpful?
Thank you for voting!
Little or no flow to water dispenser.
  • Randel from Centreville, VA
  • A Bit Difficult
  • Less than 15 mins
Adding a small amount of water to the filter would resolve the problem for a week or two. So, I thought this was an issue with the filter and decided to try the bypass cap to help zero in on the problem. The bypass cap had no instructions concerning the need for O ring so it was trial and error. The O ring was not needed. After insta llation of the bypass cap, no water flow resulted and I had to replace the filter. Intermittent problem continues.
Was this helpful?
Thank you for voting!
Both the fridge aqnd freezer would not get cold.
  • Mary from Farmingdale, NY
  • Easy
  • Less than 15 mins
  • Screw drivers
Easy. Followed the video instrucations. the part was right there next to the compressor.
Was this helpful?
Thank you for voting!
fan and compressor wont start
  • JOSE from NEW YORK, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Googled the model number of refrigerator with symptoms of "refrigerator wont run". Parts select web site appeared on my screen, opened Parts Select website, Partselect said probable cause of my frige symptom was that the run capacitor usually burns out 51% of the time. They were correct with the diagnosis 100%. I ordered the run capacito r for $23.00, installed it in 10 minutes, refrigerator runs good as new. Thank you for saving me cost of service call. I probably saved $200 or more. I will use Partselect again with my next problem. THANK YOU,
Was this helpful?
Thank you for voting!
Removed water filter as I have a whole house filter system.
  • Pamela J. from Sun City West, AZ
  • Really Easy
  • Less than 15 mins
Just removed the filter and used my hand to attach the water filter bypass cap....did not even need to turn off the water first.
Was this helpful?
Thank you for voting!
Installed whole house filter, did not need refrigerator filter
  • Walter from Temple, TX
  • Really Easy
  • Less than 15 mins
Removed water filter and inserted plug (works great and water flow increased)
Was this helpful?
Thank you for voting!
compressor running and hot, refer and fridge room temp.
  • Charles from Durham, CA
  • Really Easy
  • Less than 15 mins
Watched a youtube on capacitors- though on a motor with a pulley, the symptoms were the same, motor running and pulley not turning-bad capacitor. Took a chance for a 17+ dollar part vs a new compressor. It worked.
Was this helpful?
Thank you for voting!
Rat chewed up fan blades in refrigerator at our camp.
  • Wendell from Baton Rouge, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
We just pried off the fan blades and pushed on the new part. Could not have been easier. The rat has been permanently dipatched and, hopefully, that is that.
Was this helpful?