Dispenser flap for ice not closing. no water from dispenser was coming out.
8 of 15 people
found this instruction helpful.
-
Bart from Whitestone, NY
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers
Water line 5/16inch was severed, under refrigerator. Used union connector to join line. Dispenser plate removed using allen key to unsnap plate ,from under the plate itself. Removed screws holding solenoid valve and removed the plug from circuit board connected to solenoid. Installed new solenoid valve. Put flapper back in place, and ma
... Read more
de sure spring on left side of flapper is reattached to the opening on the flapper. This corrected all problems. Caution, keep an eye on spring that it remains in place.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Ice chute frosted up
6 of 9 people
found this instruction helpful.
-
Phillip from Springfield, VA
- Easy
- 30 - 60 mins
-
Screw drivers
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) ... Read more that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) ... Read more that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
Read less
Was this helpful?
Thank you for voting!
cold water dispenser would not stop running
5 of 6 people
found this instruction helpful.
-
Robert from Summer feild, FL
- Really Easy
- Less than 15 mins
-
Socket set
Turn off the water.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice. ... Read more
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice. ... Read more
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
Read less
Was this helpful?
Thank you for voting!
Ice maker solenoid failure
5 of 6 people
found this instruction helpful.
-
Robert from Mahopac, NY
- Easy
- Less than 15 mins
-
Screw drivers
several times I had to remove the ice maker door solenoid due to it sticking. I ordered a new one from parts select. Problem solved!!!
Was this helpful?
Thank you for voting!
broken auger in the bucket assembly.
6 of 9 people
found this instruction helpful.
-
Chip from Mandeville, LA
- Easy
- Less than 15 mins
-
Nutdriver
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
Was this helpful?
Thank you for voting!
Ice maker was over filling and freezing the cubes together.
5 of 6 people
found this instruction helpful.
-
Gary from Pickens, MS
- Really Easy
- 30 - 60 mins
-
Screw drivers
I turned water off at valve and unplugged refrigerator. I removed screws to remove cardboard cover at bottom. I removed screw holding duel inlet water valve bracket and pulled out valve. Then it's just a matter of exchanging electrical connections and water lines. The electrical connections unplug and plug in-red to red and blue to blue.
... Read more
The water lines are two different sizes so they can't be mixed up. Then reattach bracket and cardboard cover. Turn water back on and plug back in.
Read less
Was this helpful?
Thank you for voting!
light burned out
10 of 22 people
found this instruction helpful.
-
Gerald from Lincoln, CA
- Really Easy
- Less than 15 mins
unscrewed lamp and replaced it with new one!
Was this helpful?
Thank you for voting!
Water not dispensing
4 of 4 people
found this instruction helpful.
-
Alex from Tampa, FL
- Really Easy
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
Moved refrigerator forward, this allowed me to work on the back panel. Unplugged the refrigerator power cord. Released all 6 screws, removed panel then release an additional screw that was holding the water valve and the two (red & blue) connectors. Then installed the new part in reverse steps. Plug the unit and job well done. I had purch
... Read more
ase the water filter already after several minutes push for water from the dispensing front part of the refrigerator and good to go, later in the evening we notice the ice maker working fine and producing ice. Thank you parts select.
Read less
Was this helpful?
Thank you for voting!
The Icemaker failed to make ice
8 of 16 people
found this instruction helpful.
-
Dean from Folsom, CA
- Really Easy
- 15 - 30 mins
-
Screw drivers
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement i
... Read more
cemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Read less
Was this helpful?
Thank you for voting!
freezer drop temp to 12 degrees.recommended temp zero.
4 of 4 people
found this instruction helpful.
-
clyde from RIALTO, CA
- Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers
Replace the motor fan on condenser and clean the condenser
Other Parts Used:
Was this helpful?
Thank you for voting!
refrigerator not cold
4 of 4 people
found this instruction helpful.
-
Joseph from FARMINGVILLE, NY
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
removed freezer door / shelf /ice maker pulled back panel off and removed fan
Was this helpful?
Thank you for voting!
No water dispensed from door tap, icemaker OK
4 of 5 people
found this instruction helpful.
-
David from Longwood, FL
- Easy
- 15 - 30 mins
-
Nutdriver
The problem was both the valve and a frozen slug of water in the supply line located inside the door. After replacing the valve, I turned the freezer to a setting of 1 and in about 30 hours, water flowed out the tap.
Was this helpful?
Thank you for voting!
no ice made
5 of 8 people
found this instruction helpful.
-
Robert from San Marcos, CA
- Really Easy
- 15 - 30 mins
-
Screw drivers
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of s
... Read more
crews had ice again !
Read less
Was this helpful?
Thank you for voting!
Refrigerator light wouldn't come on.
4 of 5 people
found this instruction helpful.
-
Daniel from Crown Point, IN
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
Was this helpful?
Thank you for voting!
Ice build up behind ice maker ,water chute frozen up
4 of 5 people
found this instruction helpful.
-
Steven from Helotes, TX
- Easy
- 30 - 60 mins
-
Pliers
Unplugged ref.,turnned water off at wall and drained, removed back cover on lower part of ref. then removed screw holding water valve,unplugged both wires from unit,pulled the 3 water lines off,1 I had to cut, would not release,got new water valve,push 3 water lines in place,attached the 2 wires in place and screwed unit back on ref.and r
... Read more
eplaced back cover on ref. Then I got a hair dryer and thawed all ice that had built up behind and under ice maker in freezer,cleaned that mess up,turned water back on plugged in ref. All good ,repaired problem,old water valve was bad.
Read less
Was this helpful?
Thank you for voting!