Water dispenser won't always dispense water
27 of 45 people
found this instruction helpful.
-
Curtis from Corona, CA
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
I followed the instructions found on this website. I removed the control panel by inserting a small Phillips screwdriver in the three holes at its bottom. I used the same screwdriver to pull the dispenser assembly down but could have used a larger one. The microswitch could be seen in the assembly at that point and was easily removed b
... Read more
y opening the "fingers" that held it in place. I attempted to pull one of the terminals off without using a pair of needle-nosed pliers and ripped the wires right out of the terminal(I was able to find a replacement at Radio Shack). Low and behold after reinstalling the new part, it did not take care of the problem.
My problem is the water dispenser does work intermittently. When we place the glass in position and hit the lever, the lights in the control panel go off and no water is dispensed. My next guess may be the water valve or the control panel. The icemaker makes ice but I have had problems with it dispensing for nearly a year now.
My problem is the water dispenser does work intermittently. When we place the glass in position and hit the lever, the lights in the control panel go off and no water is dispensed. My next guess may be the water valve or the control panel. The icemaker makes ice but I have had problems with it dispensing for nearly a year now.
Read less
Was this helpful?
Thank you for voting!
Replace ice maker
21 of 28 people
found this instruction helpful.
-
Gary from Glendale, AZ
- Easy
- 15 - 30 mins
-
Screw drivers
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice b
... Read more
in had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Read less
Was this helpful?
Thank you for voting!
The refrigirator light would not come on.
26 of 44 people
found this instruction helpful.
-
Jania from Novato, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this helpful?
Thank you for voting!
no problem
18 of 21 people
found this instruction helpful.
-
William from West Union, SC
- Really Easy
- Less than 15 mins
I had lost the provided bypass filter plug. I decided to replace it with your part.
Was this helpful?
Thank you for voting!
Stripper on the icemaker broke into pieces.
18 of 23 people
found this instruction helpful.
-
Tracy from Yuba City, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this helpful?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
15 of 17 people
found this instruction helpful.
-
D from ZELLWOOD, FL
- Easy
- 15 - 30 mins
-
Screw drivers
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Was this helpful?
Thank you for voting!
Iced up Freezer compartment in SxS
15 of 18 people
found this instruction helpful.
-
Jamison from Heltonville, IN
- Really Easy
- Less than 15 mins
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice m
... Read more
aker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Read less
Was this helpful?
Thank you for voting!
No longer needed water filters
22 of 39 people
found this instruction helpful.
-
Jeffrey from Williamsburg, VA
- Really Easy
- Less than 15 mins
Your website was very easy to use and the product shipped very promptly. It was great experience. Thanks!
Was this helpful?
Thank you for voting!
freezer fan failing; veried speed making whirling sounds
14 of 16 people
found this instruction helpful.
-
Jason` from Colchester, CT
- Easy
- 1- 2 hours
-
Nutdriver
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that
... Read more
held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
Read less
Was this helpful?
Thank you for voting!
ice maker not making ice
16 of 22 people
found this instruction helpful.
-
Cristina from Los Angeles, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Was this helpful?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
19 of 33 people
found this instruction helpful.
-
Terry from Simi Valley, CA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring s
... Read more
o it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Read less
Was this helpful?
Thank you for voting!
my refrgerator stopped cooling and freezing
12 of 12 people
found this instruction helpful.
-
Mike from Aguilar, CO
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
Take the cardboard grill off the bottom of the back it is held on with 5-6 hex head screws. Located the voltage inverter on the tank. It's on the bottom left of the refrigerator. Removed the screw that holds it in place.Remove the jumper wires at the quick connect. Rotate the voltage inverter and removed it. Check the voltage at the plug
... Read more
in going to the voltage Inverter. It should be 115-125 volts. Plug in the voltage inverter to the Quick connect away from the tank check the voltage on the side that would be connected to the tank. If both sides don't read at least 115 volts the inverter is bad. Order a new on and reinstall in the reverse order.
Read less
Was this helpful?
Thank you for voting!
icemaker developed a leak and froze over
18 of 30 people
found this instruction helpful.
-
debbie from chino hills, CA
- Easy
- 15 - 30 mins
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Was this helpful?
Thank you for voting!
Loud knocking noise with the evaporator fan
13 of 15 people
found this instruction helpful.
-
lk from carlsbad, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).
I wasn't so sure all that noise would come from the Evaporator Fan mot ... Read more or so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
I wasn't so sure all that noise would come from the Evaporator Fan mot ... Read more or so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
Read less
Was this helpful?
Thank you for voting!
Ice maker ot making ice
18 of 31 people
found this instruction helpful.
-
Barry from Phoenix, AZ
- Easy
- 15 - 30 mins
-
Nutdriver
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Was this helpful?
Thank you for voting!