- Home
- ZIF360NXALH
- Instructions
ZIF360NXALH General Electric Freezer - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Not Cooling
4 of 4 people
found this instruction helpful.
-
ROBERT from OCALA, FL
- Really Easy
- 30 - 60 mins
-
Screw drivers, Wrench set
-Pulled refrigerator out to access back.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
- ... Read more Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
- ... Read more Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
Read less
Was this helpful?
Thank you for voting!
INTERMITENT LOUD NOISE FROM EVAPORATOR FAN IN FREEZER
4 of 5 people
found this instruction helpful.
-
Bert from SAN JOSE, CA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers
The repair did not go exactly the way it was described in the YouTube video, but basically it was similar. After unplugging the power cord, emptying the freezer, removing the shelves and the ice reservoir, I removed the ice maker assembly by unscrewing a Philips head screw and unplugging the power connector. The connector had little ret
... Read more
aining tabs on each side that I pried open with a straight blade screwdriver. Then the ice maker lifted right out. Next I removed one screw holding the auger motor assembly, unplugged the power connector, and lifted out the assembly. This where things got difficult. After flailing around a bit, I removed the panel on the back wall of the freezer below the evaporator fan assembly, exposing the evaporator coil. I saw that the fan assembly was attached with two screws at the top and two screws at the bottom. The top screws were easily removed, but when I removed the bottom screws, which were situated in very tight quarters, I DROPPED BOTH SCREWS DOWN BEHIND THE EVAPORATOR COIL. Be prepared with a magnetic nutdriver so this doesn't happen to you. I could not retrieve the lost screws, but fortunately it appears that the top screws hold the assembly securely enough. The assembly was loose, but it was still attached by a power cord that I could not disconnect. I removed the tracks on the side walls for the ice bucket, and then I could maneuver the fan motor assembly just enough that I could reach over the top of it, grab and pull off the old fan blade, and slide the new fan blade onto the shaft. Reassembly was straightforward, replacing each part (except two lost screws) in reverse order to disassembly. After getting everything put back in and plugging in the power cord, I was amazed at how quiet it ran.
Read less
Was this helpful?
Thank you for voting!
compressor won't kick on
3 of 3 people
found this instruction helpful.
-
Kenneth from RINGGOLD, GA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
Pulled ice box away from wall. Took lower cardboard cover off. Shut water line off. Got my volt meter and checked the current going from the wall to the plug in at the inverter (input side), and I had the required 115 volts. Then I unplugged the connection going to the compressor (not the plug at the compressor which you cannot see until
... Read more
you unbolt the inverter) but the output connection side that goes to compressor. I checked the voltage and had about 13 volts not the required 115 volts. Therefore, I came to the conclusion that the inverter was bad. I ordered one from Partselect and they shipped it right away. I installed it and the ice box is back up to running order.
Read less
Was this helpful?
Thank you for voting!
Nothing to tell it was a replacement
3 of 3 people
found this instruction helpful.
-
Royce from Pasadena, TX
- Really Easy
- Less than 15 mins
Nothing to tell it was just a replacement part that the old part was removed and the new one inserted. Works like a dream Thanks
Was this helpful?
Thank you for voting!
replace filter
5 of 9 people
found this instruction helpful.
-
Marie from Philidelphia, PA
- Really Easy
- Less than 15 mins
just had to unscrew old one put the new one in
Was this helpful?
Thank you for voting!
Solenoid wasnt pumping water to the ice maker
3 of 5 people
found this instruction helpful.
-
Michael from Boyds, MD
- Easy
- 30 - 60 mins
-
Screw drivers
I started by shutting off the water inlet valve and then unplugged the refrgerator. I then disconnected the tubing leading into the solnoid. Removed the old solenoid, replaced it with the new part reconnectted the tubing and gave it a test run. After about 2 hours we had ice being made again! I then reconnected the bracket to the refr
... Read more
igerator and haven't had a problem since.
Read less
Was this helpful?
Thank you for voting!
Squeky Evaporator Fan
2 of 2 people
found this instruction helpful.
-
Douglas from LAFAYETTE, LA
- Really Easy
- 30 - 60 mins
-
Screw drivers
I made my wife fix it.
Was this helpful?
Thank you for voting!
Not cooling the bottom
2 of 2 people
found this instruction helpful.
-
John M from SAN ANTONIO, TX
- Really Easy
- 15 - 30 mins
-
Socket set
Disconnect the refrigerator, remove & installed new fan evaporator motor
Was this helpful?
Thank you for voting!
water line cracked
2 of 3 people
found this instruction helpful.
-
RUSSELL from BLACK HAWK, SD
- Very Easy
- Less than 15 mins
I loosened the compression nut on the valve with my fingers and pulled the water line free from the valve. On the other end, I just pulled it from the hose clamp. Installation in reverse. Force the water line into the fitting on top, Slide the old nut over the line on the bottom. Screw the nut onto the valve. Reach inside the freeze
... Read more
r and turn on the ice maker. Done. Before replacing the cardboard grill, you should vacuum the coils on the bottom, front and back. If practical, push it outside and blow it out with an air compressor or a leaf blower.
Read less
Was this helpful?
Thank you for voting!
old motor was making a clicking noise.
2 of 3 people
found this instruction helpful.
-
ROBERT from LA GRANGE, KY
- Very Easy
- 15 - 30 mins
-
Nutdriver
unplugged appliance. removed cover from back of fridge. unplugged wiring to condenser. pulled fan blade from motor. removed two bolts from fan bracket.removed fan blade and then motor. cleaned fan blade and all surrounding parts.installed new fan and blade. plugged fan motor back in re-installed cover on back of fridge.plugged fridge back
... Read more
in.motor is now nice and quiet.
Read less
Was this helpful?
Thank you for voting!
Replace water filter with bypass plug - filter is redundant with home osmosis system
2 of 3 people
found this instruction helpful.
-
Fred from LA QUINTA, CA
- Very Easy
- Less than 15 mins
-
Screw drivers
If you have a reverse osmosis system for filtered water system in your home that also feeds the refrigerator, using another water filter in the refrigerator is redundant, so GE makes a Water filter Bypass Cap that allows you to run using the already filtered water without needing to expensive water filter. FIRST - using a phillips screw
... Read more
driver remove the toe kick plate at the bottom front of the refrigerator - two screws - one on each side of the plate that extends the entire width of the refrigerator. SECOND - Locate the water line (should be right in front) and the valve to turn off the water. Turn valve clockwise (right) until completely closed. Then test by attempting to fill a glass with water using the dispenser on the door. If any water continues to come out, continue turning the valve (without forcing it) clockwise until it has been turned as much as possible. If water still comes from dispenser, locate the source of the water line - most likely from under the kitchen sink. There should be another valve under the sink, or simply turn off (turn the cold water valve clockwise) until water cold water completely turned off. Test again as required. THIRD - clear the top right hand back shelf directly under the water filter screwed into the ceiling of the refrigerator in the rear top right side of the refrigerator. Place a small towel under the water filter, and slowly turn the filter 1/4 turn clockwise without using force. Continue turning until the full 1/4 turn is complete and the filter will drop down without pulling. Place the old filter upside down in the sink, thereby allowing the filter to drain any water present in the filter. FOURTH - remove the filter plug from package, notice notches in top of plug that align with gaps in the area where a filter would typically be screwed into the filter location in the ceiling above the top right shelf in the refrigerator. After aligning notches in the bypass plug with gaps in the screw mechanism, carefully turn the bypass plug 1/4 turn counter- clockwise - at which time the bypass plug should be firmly installed. FIFTH - Reverse step SECOND, and turn valve Counter-Clockwise until valve is completely open. Test to ensure no water is leaking from the Bypass Plug. SIXTH - Finally reverse step FIRST by reattaching the toe kick plate using the two phillips screws removed in Step FIRST. NOTE: The Bypass Plug is quite inexpensive, but after adding shipping from Canada - the cost is about the same as purchasing a new filter for the refrigerator. :-(
Read less
Was this helpful?
Thank you for voting!
Defroster fan burned up
3 of 6 people
found this instruction helpful.
-
Peter M. from Lincoln Park, NJ
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Socket set
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Was this helpful?
Thank you for voting!
Yearly replacement of filter
2 of 3 people
found this instruction helpful.
-
Robert from Myrtle Beach, SC
- Really Easy
- Less than 15 mins
Moved stuff out of my way on the top shelf, reached in and turned old filter to remove. Filled new filter with water, lined up and turned to lock in place. Whew, never thought I would get that job done. :-)
Was this helpful?
Thank you for voting!
Water dispensed at a trickle
3 of 7 people
found this instruction helpful.
-
JAMES from MORENO VALLEY, CA
- Really Easy
- Less than 15 mins
I only had to remove the old filter and install the new one - all by hand. I then ran about 1 to 1and1/2 gallons of water through the filter to clear it.
A WORD OF CAUTION - HOLD YOUR GLASS CLOSE TO THE WATER DISPENSER FOR THE INITIAL FILLING - IT WILL SPIT UNTIL THE AIR IS PURGED FROM THE SYSTEM!!!
An extremely easy repair.
A WORD OF CAUTION - HOLD YOUR GLASS CLOSE TO THE WATER DISPENSER FOR THE INITIAL FILLING - IT WILL SPIT UNTIL THE AIR IS PURGED FROM THE SYSTEM!!!
An extremely easy repair.
Was this helpful?
Thank you for voting!
Auto water stopped working, found that filter needed replacement
2 of 4 people
found this instruction helpful.
-
Joanne from Fort Smith, AR
- Really Easy
- Less than 15 mins
Unscrewed old cartridge, ordered new cartridge, installed new cartridge by following very simple instructions. Took only one day for part to arrive from PartSelect although I paid for cheapest shipping, which was "ground." I was amazed!
Was this helpful?
Thank you for voting!