ZICP720BSESS General Electric Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
Parts Used:
-
clyde from RIALTO, CA
-
Difficulty Level:Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker solenoid housing cracked
The original piece was already removed. installation required a little custom fitting as the mounting was slightly different and the copper tubing from the water line needed to be bent to fit. The push in plastic connection (output to the icemaker itself ) was simple ( I was a little leary of it not leaking.)
I plugged in the solenoid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
I plugged in the solenoid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
Parts Used:
-
Mark from Bayside, NY
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
5 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Wasn't Getting Any Water To The Icemaker
It could not have been easier. The new part matched the old part exactly. I turned the water off going to the refrigerator, unscrewed one screw from the old part, pulled the electric plug loose, disconnect the copper water line from old part, cut off the black plastic tube next to the water valve going to the icemaker, and the new water valve was ready to install. It's that simple. I then took the new water valve, connected the copper water line to it, pushed the black plastic water line into its hole, connected the electric plug, and screwed the new part onto the refrigerater. In a matter of minutes I had water running to my icemaker again. I can't imagine the money I saved by doing this simple project myself. This took less than 10 minutes.
Parts Used:
-
Mark from Ft. Lauderdale, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
5 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator not cold
removed freezer door / shelf /ice maker pulled back panel off and removed fan
Parts Used:
-
Joseph from FARMINGVILLE, NY
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not Cooling
-Pulled refrigerator out to access back.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
-Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
-Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
Parts Used:
-
ROBERT from OCALA, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Wrench set
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker water valve failed open.
The replacement single outlet water valve was not an exact replacement and required a slightly different mounting position. The original plastic hose to the ice maker attached to the valve with a plastic nut. The new connection requires only pushing the hose into a hole in the valve. Easy and simple. However, the new mounting angle promptly broke the brittle old plastic hose. I was able to pick the broken pieces of hose out of the valve with a fine point pick saving the new valve. If I hadn't been able to pick the broken pieces out of the new valve I would have had to order another one. Off to the big box store to buy new 1/4 inch plastic hose and a coupler. Repair completed and no leaks. If the hose hadn't broken, the I would have been done in 15 minutes. I suggest you plan to replace the entire plastic hose when you replace the valve.
Parts Used:
-
O. V. from Virginia Beach, VA
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers, Socket set, Wrench set
5 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
Parts Used:
-
Robert from San Marcos, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
5 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working.
I first replaced the ice maker and when that didn't work, I found out through this forum that another possibility is the water outlet valve.
When I got the replacement, it took some time to install because the bracket wasn't the same as the original. There are enough places on the bracket to mount the unit, but it may require using some force to bend the bracket so that it will flush with the wall.
After installation, it took about 2 days to fill up the ice bin. It cycles out ice crescents every 2-3 hours.
Thanks partselect for having this forum and saving me some money by having others share their experiences.
When I got the replacement, it took some time to install because the bracket wasn't the same as the original. There are enough places on the bracket to mount the unit, but it may require using some force to bend the bracket so that it will flush with the wall.
After installation, it took about 2 days to fill up the ice bin. It cycles out ice crescents every 2-3 hours.
Thanks partselect for having this forum and saving me some money by having others share their experiences.
Parts Used:
-
Alice from Vancouver, WA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers, Socket set
5 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cracked valve
Super simple. Extremely fast delivery of part. Simply disconnect the 2 fast-on connectors to valve, disconnect intake and out lines. connect intake and out tubes to new unit, mount via screws to fridge, reconnect the 2 fast-on power connectors and your back in business. Could not be an easier repair.
Parts Used:
-
Don from Crete, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
6 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Nothing to tell it was a replacement
Nothing to tell it was just a replacement part that the old part was removed and the new one inserted. Works like a dream Thanks
Parts Used:
-
Royce from Pasadena, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker needed replacement
Unplug refridge then loosened two bolts holding old ice maker. Lower then unplug and removed. Plugged in new harness and tightened two bolts to secure new ice maker. Plug in frig and wait for ice.
Parts Used:
-
James from PLYMOUTH, MA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replace filter
-
Marie from Philidelphia, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
5 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken outlet valve
All the repair people was on the money . I read them all .1--- NO paper work with new valve (.no instructions) ..2--- bracket is not the same .. I reversed my braket and it worked fine .you do not have to bend bracket.3--- It will take a day or so to start making ice..4--- the plastic nut is no longer needed on the new type outlet valve ....5--- the new outlet valve looks a little different from the old valve. WORKS GREAT ..
Parts Used:
-
KEITH from WINDER, GA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
5 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
Parts Used:
-
Lynn from MOUNTAIN HOME, ID
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor won't kick on
Pulled ice box away from wall. Took lower cardboard cover off. Shut water line off. Got my volt meter and checked the current going from the wall to the plug in at the inverter (input side), and I had the required 115 volts. Then I unplugged the connection going to the compressor (not the plug at the compressor which you cannot see until you unbolt the inverter) but the output connection side that goes to compressor. I checked the voltage and had about 13 volts not the required 115 volts. Therefore, I came to the conclusion that the inverter was bad. I ordered one from Partselect and they shipped it right away. I installed it and the ice box is back up to running order.
Parts Used:
-
Kenneth from RINGGOLD, GA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
3 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!