Everything Worked Fine But It Stopped Heating The Food.
1 of 2 people found this instruction helpful.
  • ROBERT from GAINESVILLE, TX
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Take the four saftey torx screws off the back of microwave that hold the side panels on. There are no screws in the front. Just pick up the side panels a little and slide towards the back of microwave and it will come off. The magnetron is visible behind control panel. Unplug the magetron, take a 3/8 nut driver , remove the one bolt that holds it on , remove and replace with the new one. Plug the wire (it will only go one way) back up and replace cover.
Was this helpful?
Thank you for voting!
was loud when cookiing
1 of 5 people found this instruction helpful.
  • Craig from Portage, MI
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Went well, very easy to change once the microwave was out of the wall. Sounds better than when it was new.
Was this helpful?
Thank you for voting!
Not heat function
  • James from Skillman, NJ
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Went through diagnosis of the product, unit was not heating, fund the following items that were faulty, Wave unit was n/g, transformer ohm specs were n/g, also replaced main board due to poor LED visibility, changed out diode and capacitor due to age of the unit, unit working perfectly now.
Was this helpful?
Thank you for voting!
Micowave not heating food.
  • Corey from Greenville, NC
  • Easy
  • 30 - 60 mins
  • Screw drivers, Socket set
I just took off the cover, located the magnetron, replaced it and slapped everything back together and since then everything's been working pretty good.
Was this helpful?
Thank you for voting!
No problems
  • Donald from New Orleans, LA
  • Really Easy
  • Less than 15 mins
Remove the Glass rotating tray and replace the guide
Was this helpful?
Thank you for voting!
tray would slowly rotate when door was open.
  • Bruce from Hanover Park, IL
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
I determined that one of the 4 micro switches that interface with the door was faulty. Ordered that part and replaced it. Had to remove the cover and front control panel (without removing any connections. Two philips screws hold the limit switch assembly to the bracket. After removing those screws, twist the whole switch assembly clockwis e around the mounting frame and now you can remove the defective micro switch and replace it with a new one. This works for any of the 4 switches.
Was this helpful?
Thank you for voting!
Glass cooking tray broken
  • John from Laurel, NY
  • Really Easy
  • Less than 15 mins
Simply replaaced broken cooking tray
Was this helpful?
Thank you for voting!
broken glass tray
  • Jeff from Warner Robins, GA
  • Really Easy
  • Less than 15 mins
just placed it on the wheel
Was this helpful?
Thank you for voting!
door facing was cracked
  • Robert J from Orange, CA
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers
had to remove entire micxrowave shell to access door. screws needed special screwdriver. removed shell, removed damaged door and repaced with new door. replaced shell. Would have been better if instructions for repacement were included.
Was this helpful?
Thank you for voting!