I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people
found this instruction helpful.
-
gary from ARANSAS PASS, TX
- Easy
- 30 - 60 mins
-
Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though ... Read more it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Read less
Was this helpful?
Thank you for voting!
freezer defrost would melt the food
4 of 5 people
found this instruction helpful.
-
Joseph from West Allis, WI
- Really Easy
- Less than 15 mins
-
Nutdriver
Looked up similar problems and found it to be the defrost timer. All I had to do was remove the plastic portion in the fridge section to get to the old timer. Popped the new one in and put it back together. Works great now. Would have been almost $150 to have a repair company come out and fix it.
Was this helpful?
Thank you for voting!
Freezer icing up and refrigerator section not cold
3 of 3 people
found this instruction helpful.
-
Les from Fenton, MO
- Really Easy
- Less than 15 mins
-
Nutdriver
Removed four screws for cover on refrigerator temperature controls, unpluged old timer and pluged in new timer. Replaced cover and screws.
Was this helpful?
Thank you for voting!
Old Defrost Timer Noisy During Operation
3 of 3 people
found this instruction helpful.
-
Vernon from Granada Hills, CA
- Easy
- 15 - 30 mins
-
Socket set
First I removed the plastic grill (pulled out, no screws) from bottom of refrigerator, then I removed electrical plug & two screws from old timer (timer located on the front inside left lower side of refrigerator). Installed in reverse order.
Was this helpful?
Thank you for voting!
Repaired Oven Range Light Bulb
3 of 3 people
found this instruction helpful.
-
Alan from SAN MATEO, CA
- Very Easy
- Less than 15 mins
-
Screw drivers
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
Was this helpful?
Thank you for voting!
Freezer frosted up, refrigerator compartment heated up
3 of 3 people
found this instruction helpful.
-
James from Hanover, ME
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I removed the housing at the top of the refrigerator compartment that contained the reefer light and temperature adjustment knob. This required a small nut-driver. Inside, I found the old defrost control, unplugged it, unscrewed it with a Phillips screwdriver, and replaced it with the replacement part. Then I replaced the housing to its o
... Read more
riginal position.
Read less
Was this helpful?
Thank you for voting!
Freezer too cold
3 of 3 people
found this instruction helpful.
-
Curt from Maple Grove, MN
- Really Easy
- 15 - 30 mins
-
Nutdriver
Removed the housing with the light, 4 hexhead screws. This exposed the defrost timer, removed 2 hexhead screws, electrical connector and reassembled the unit.
Great resource and service, thank you.
Great resource and service, thank you.
Was this helpful?
Thank you for voting!
freezer would frost up and not get cold enough to keep frozen.
3 of 3 people
found this instruction helpful.
-
Richard from SLIDELL, LA
- Very Easy
- 15 - 30 mins
-
Screw drivers
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
Was this helpful?
Thank you for voting!
sometimes it would go into defrost and would not go back to cooling.
3 of 3 people
found this instruction helpful.
-
Henry D from PETERSTOWN, WV
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I called the repairman who diagnosed the problem as a thermostat then had to order a thermostat took about 2 weeks to get back and install (cost little over $100). did good for about two weeks and same problem reoccured. I decided it was defrost timer and ordered from this site for $19.95 including shipping. I got on ( you tube ) and got
... Read more
instructions(recommend you tube) for DIY install about 15 to 20 minutes. Has been running great for about 3 weeks. ( YOU TUBE IS GREAT FOR A DIY REPAIR ON ABOUT ANYTHING)
Read less
Was this helpful?
Thank you for voting!
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
3 of 3 people
found this instruction helpful.
-
Tunis from NOLANVILLE, TX
- Easy
- 15 - 30 mins
-
Screw drivers
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
Was this helpful?
Thank you for voting!
Motor squeal
3 of 3 people
found this instruction helpful.
-
Mark from Partlow, VA
- Very Difficult
- 30 - 60 mins
-
Socket set
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
Was this helpful?
Thank you for voting!
defrost heater not working; defrost timer not rotating so coils ice up
3 of 3 people
found this instruction helpful.
-
James from VOLANT, PA
- Easy
- 1- 2 hours
-
Nutdriver, Screw drivers
Checked for continuity in heater, defrost thermostat and defrost timer. Heater good; not sure about thermostat or timer. Replaced thermostat - no change. Replaced timer - rotating and heater working.
Was this helpful?
Thank you for voting!
The refrigerator wasn't cold enough.
3 of 4 people
found this instruction helpful.
-
John from San Diego, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
I removed the plastic shroud on the ceiling of the refigerator, unscrewed and unplugged the old defrost timer, and replaced it with the new one. I reinstalled the shroud with the new timer installed.
Was this helpful?
Thank you for voting!
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
2 of 2 people
found this instruction helpful.
-
Jerry from PHOENIX, AZ
- Really Easy
- 15 - 30 mins
-
Socket set
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for t
... Read more
he fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
Read less
Was this helpful?
Thank you for voting!
freezing up
2 of 2 people
found this instruction helpful.
-
Kenneth from ADGER, AL
- Very Easy
- 15 - 30 mins
-
Screw drivers
I damaged the timer while moving the fridge and did not realize it and it took 10 minutes to change out. "note" don't panic when it don't come immediately there is a dial in the front of the timer you can turn with a flat head screwdriver that will activate the timer
Other Parts Used:
Was this helpful?
Thank you for voting!