Side-by-side .. freezer working, fridge not cooling
48 of 52 people found this instruction helpful.
  • Tad from Lancaster, OH
  • Easy
  • 15 - 30 mins
  • Screw drivers
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc . After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
Was this helpful?
Thank you for voting!
Light socket melted around bulb
66 of 108 people found this instruction helpful.
  • William from Alexandria, VA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
After unsuccessfully trying to change the blown light bulb I discovered that the plastic light socket had gotten so hot that it melted and permanently fused with the blown bulb. After my new socket arrived in the mail I just popped the temp control assembly out with a screw driver and removed the old socket and placed the new one in. Whole operation to 5 minutes.
Was this helpful?
Thank you for voting!
no cooling in fridge or freezer due to bad defrost timer
29 of 37 people found this instruction helpful.
  • Todd from pottstown, PA
  • Easy
  • Less than 15 mins
  • Screw drivers
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.
Was this helpful?
Thank you for voting!
The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.
24 of 27 people found this instruction helpful.
  • Erle from Boise, ID
  • Easy
  • 15 - 30 mins
  • Screw drivers
First, unplug the refrigerator since you're working with live wires.

Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the re frigerator during the defrost cycle.

Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.

Attach the new defrost timer to the plastic housing with the 2 screws.

Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.

Plug the refrigerator back in and you're done.
Was this helpful?
Thank you for voting!
Refrigerator freezing
22 of 30 people found this instruction helpful.
  • Miles from Longview, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.
Was this helpful?
Thank you for voting!
Fridge side warm. Freezer was ok.
13 of 15 people found this instruction helpful.
  • Doug from Folsom, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Popped off the front plastic cover on the bottom of the fridge, under the doors. Two screws held the defrost timer on under the front side of fridge (below freezer door). You can't really see the timer except for the adjustment knob that is accessible through a hole. Once the screws are removed, disconnect the wire plug and remove and re placed unit. Works fine ever since.
Was this helpful?
Thank you for voting!
Fan Noise
11 of 13 people found this instruction helpful.
  • Kenneth from Springfield,, TN
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
took cover off inside freezer control . removed old fan and unpluged wire harness plugged new one up and fastened back in place and put control cover back on.
Was this helpful?
Thank you for voting!
Freezer starter acumulating lots of ice and the lower part of fridge was not cooling at all.
9 of 10 people found this instruction helpful.
  • alonso from Compton, CA
  • Easy
  • 15 - 30 mins
  • Wrench (Adjustable)
just took the back cover of the freezer of and then the fan. To do this, I just removed like four bolts at the corners and then four bolts that attached the fan to the cover. At the end, I just unplugged the cables. I got my new fan the very next day, which was like extremly fast, plug in the cables and attached the fan to the cover and t hen attached the cover to the original place. It's a pretty simple repair. My fridge is now working like it should be.
Was this helpful?
Thank you for voting!
the evaporator fan stopped working
8 of 11 people found this instruction helpful.
  • Stephen from Bloomfield, NJ
  • Easy
  • 15 - 30 mins
  • Screw drivers
I removed the plastic cowl in the rear of the freezer to gain access to the fan, took out two screws that secured the brackets holding the fan. Then I separated the coupling wires which had a sort of locking mechanism that was simple to undue. I took out the brackets along with the fan, separated the brackets and removed the screw for the ground wire. Then I simply reversed the process.
Was this helpful?
Thank you for voting!
Thought the evaporator fan was the issue
7 of 8 people found this instruction helpful.
  • Dale from Fort Myers, FL
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
Did the obvious. Removed the stick-out cover, then the back of the freezer wall, after taking the bad evaporator fan out. Replaced the old motor with the new one, stuck the fan blades back on, and put the replacement back in place. Checked to see that the new motor and fan, before final hook up, had no issues. That was a success. How ever, when I put the parts in place, I had some significant vibrations. By taking things apart and re-doing the install, the vibrations went away. However, the final install, even if quiet, did not work. Apparently the condenser was kaput. No cooling after all the adjustments. We gave up and are replacing the fridge.
Was this helpful?
Thank you for voting!
Oven light bulb went dark; it needed replacing
10 of 17 people found this instruction helpful.
  • Lise from CEDAR GROVE, NJ
  • Very Easy
  • Less than 15 mins
Twisted replacement bulb into place easily. Let there be light!
Was this helpful?
Thank you for voting!
fan motor worn out
7 of 9 people found this instruction helpful.
  • Richard from Norman, OK
  • A Bit Difficult
  • 15 - 30 mins
  • Screw drivers
Removed the old and installed the new. Electrical plug/socket made connection easy. Biggest problem is working space in freezer side of a side by side with the fan in the back. If I can do it anyone can.
Was this helpful?
Thank you for voting!
Refrigerator Light bulb went out
7 of 12 people found this instruction helpful.
  • ANGELA from MEBANE, NC
  • Very Easy
  • Less than 15 mins
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
Was this helpful?
Thank you for voting!
unit quit cooling
5 of 6 people found this instruction helpful.
  • Steve from Cedar Park, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
Was this helpful?
Thank you for voting!
the evaporator fan quit when we had a power surge
5 of 7 people found this instruction helpful.
  • Darrell from Bentley, ND
  • Easy
  • 15 - 30 mins
  • Screw drivers
A screw driver was used to remove two screws that held the old fan in place the new fan ws installed exactly where the old one came out and presto the job was complete. No major deal.