Freezer starter acumulating lots of ice and the lower part of fridge was not cooling at all.
9 of 10 people found this instruction helpful.
  • alonso from Compton, CA
  • Easy
  • 15 - 30 mins
  • Wrench (Adjustable)
just took the back cover of the freezer of and then the fan. To do this, I just removed like four bolts at the corners and then four bolts that attached the fan to the cover. At the end, I just unplugged the cables. I got my new fan the very next day, which was like extremly fast, plug in the cables and attached the fan to the cover and t hen attached the cover to the original place. It's a pretty simple repair. My fridge is now working like it should be.
Was this helpful?
Thank you for voting!
The fridge motor was running constantly and the fridge was warm inside
9 of 10 people found this instruction helpful.
  • James from Brighton, TN
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
I secured the power to the fridge. I took the metal panel which covers the cooling coils in the freezer off by removing the the 6 sheet metal screws. I used a standard hair dryer to melt the ice block which had formed due to the failure of the defrost timer. I replace the defrost timer, which was located behind the left front wheel of the unit. Finding the timer was the hardest part of the job. Since I was having trouble with the defrost cycle I also decided to replace the defrost thermostat due to its age. The most important item I would like to share is once all the work is done and the panel is back in the freezer, the power is restored take a straight slot screw driver and give the defrost timer about an eighth of a turn clockwise to ensure it starts. Then mark it with a sharpe and check it in 3 or 4 hours to make sure it is running. I did not do this on the one I installed and the freezer did not go into the defrost cycle. Once I got the timer started, well the ice cream stay frozen. BE SURE NOT TO WORK ON YOUR EQUIPMENT WITH IT PLUGGED INTO POWER SOURCE!!!

Jim
Was this helpful?
Thank you for voting!
Drip pan had rusted & was leaking water on the floor
9 of 10 people found this instruction helpful.
  • John from Forest, VA
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Wrench (Adjustable)
The BIG problem was getting the old drip pan off. The bolt on top of the compressor was too long to allow the removal of the old drip pan. I removed the old drip pan by cutting most of it away with tin shears then cutting the remaining part of the pan around the bolt with a hack saw (taking care not to damage freon lines and raising the p an above the threads of the bolt so as not to damage the threads). I still had to cut half the bolt away with a hack saw by replacing the nut and cutting a third of the bolt away (above the nut), so the new pan would fit. Putting the new pan on was a breeze after that. It may be easier to just cut the bolt off altogether on top of the compressor and use the wire clips per the instructions supplied with the kit to install the new one.
Was this helpful?
Thank you for voting!
Erratic light.
9 of 11 people found this instruction helpful.
  • D KIRKE from CORVALLIS, OR
  • Really Easy
  • Less than 15 mins
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement s witch.
Was this helpful?
Thank you for voting!
refrigerator door would not close
9 of 12 people found this instruction helpful.
  • Joseph from Biglerville, PA
  • Easy
  • 30 - 60 mins
  • Screw drivers
1. turn off the refrigerator using the inside temp dial
2. take all food out of the refrigerator door
3. pull up the gasket along the door frame and loosen all
the screws starting with the bottom and the sides
4. loosen the screws underneath the gasket on the top of
the door (be ready to lower the doo r frame when you
loosen the last screw!)
5. pull the old gasket off the door frame
6. put the door frame on the floor insulation side up
7. lay the new gasket out on the floor and use a blow
dryer to heat the new gasket to make it flexible
8. put the new gasket on the frame by fitting the crease
of the gasket over the edge of the frame making sure
that the magnet side of the new gasket is facing the
refrigerator when the frame is re-attached
9. apply RTV Silicone sealant along the entire lip of the
gasket (on the insulation side of the frame) and press
the gasket to the frame to form a bond ( I got a tube
of RTV silicone at Wal-Mart in the automotive dept. near
the motor oils)
10. wait 5-10 minutes to let the silicone bond to the frame
11. lift the frame up and re-attach to the door starting
with the top middle screw first, the side middle screws
next, the bottom middle screw last (you may want to get
a second person to help hold the frame while you are
attaching these initial screws)
12. go back and re-attach all remaining screws
13. close the refrigerator door and check for a good seal
all along the gasket
14. your done!

Note: you may want to close the refrigerator door and block
it with a chair to keep in some cold air after you
remove the frame to install the new gasket
Was this helpful?
Thank you for voting!
freezer and refrigerator too warm
9 of 13 people found this instruction helpful.
  • Joel from Sunny Isles Beach, FL
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver, Pliers
I put the refrigerator and saw that the fan wasn't working so I change the fan and the problem still the same. I order a timer and thermostat and change them, nothing change so I order the capacitor and when I remove it I saw that the relay swith was burn out so I order a switch and evarything is ok.
The problem when the fan broke th e compressor overheat and burn the swich.
I learn a lot and still saving money over these repair guy.

Thanks
Was this helpful?
Thank you for voting!
Thought the evaporator fan was the issue
7 of 8 people found this instruction helpful.
  • Dale from Fort Myers, FL
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
Did the obvious. Removed the stick-out cover, then the back of the freezer wall, after taking the bad evaporator fan out. Replaced the old motor with the new one, stuck the fan blades back on, and put the replacement back in place. Checked to see that the new motor and fan, before final hook up, had no issues. That was a success. How ever, when I put the parts in place, I had some significant vibrations. By taking things apart and re-doing the install, the vibrations went away. However, the final install, even if quiet, did not work. Apparently the condenser was kaput. No cooling after all the adjustments. We gave up and are replacing the fridge.
Was this helpful?
Thank you for voting!
Oven light bulb went dark; it needed replacing
10 of 17 people found this instruction helpful.
  • Lise from CEDAR GROVE, NJ
  • Very Easy
  • Less than 15 mins
Twisted replacement bulb into place easily. Let there be light!
Was this helpful?
Thank you for voting!
the evaporator fan stopped working
8 of 11 people found this instruction helpful.
  • Stephen from Bloomfield, NJ
  • Easy
  • 15 - 30 mins
  • Screw drivers
I removed the plastic cowl in the rear of the freezer to gain access to the fan, took out two screws that secured the brackets holding the fan. Then I separated the coupling wires which had a sort of locking mechanism that was simple to undue. I took out the brackets along with the fan, separated the brackets and removed the screw for the ground wire. Then I simply reversed the process.
Was this helpful?
Thank you for voting!
fan motor worn out
7 of 9 people found this instruction helpful.
  • Richard from Norman, OK
  • A Bit Difficult
  • 15 - 30 mins
  • Screw drivers
Removed the old and installed the new. Electrical plug/socket made connection easy. Biggest problem is working space in freezer side of a side by side with the fan in the back. If I can do it anyone can.
Was this helpful?
Thank you for voting!
replaced door seal
6 of 7 people found this instruction helpful.
  • Doug from Jonesville, MI
  • Easy
  • 15 - 30 mins
  • Nutdriver
followed documentation from Frigidaire website.
Was this helpful?
Thank you for voting!
Freezer frosted up
6 of 7 people found this instruction helpful.
  • Gregg from Mohnton, PA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Wrench set
Removed old thermostat and replaced. really easy.
Was this helpful?
Thank you for voting!
Both the Freezer and Refrigerator Seals were defeated.
6 of 7 people found this instruction helpful.
  • Laura from Beaver, PA
  • Easy
  • 1- 2 hours
  • Nutdriver
You lift the old seal and unscrew the nut, being careful not to break the plastic holding the seal down, do not remove the screw the whole way. If you take your time and be methodic it is not difficult, just time consuming. Remove the old seal and start putting the new seal in. I would advise finger tightening the screws every 12 inches o r so as you go. Then go back and tighten each side as you complete it.
Was this helpful?
Thank you for voting!
Coils freezing up and refrigerator would get warm
6 of 7 people found this instruction helpful.
  • Richard from Scranton, KS
  • Easy
  • 15 - 30 mins
  • Nutdriver
Wasn't sure if it was the derost timer or the heating element. Since the timer was much cheaper, I bought it and crossed my fingers.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Succe ss! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
Was this helpful?
Thank you for voting!
Freezer was getting a build up of frost on the condenser and wasn't cooling.
5 of 5 people found this instruction helpful.
  • Arthur from Lithonia, GA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
Was this helpful?
Thank you for voting!