fan motor had gone bad
1 of 2 people
found this instruction helpful.
-
william from whitwell, TN
- Easy
- 30 - 60 mins
-
Screw drivers, Socket set, Wrench set
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
Was this helpful?
Thank you for voting!
cooling fan quit
1 of 2 people
found this instruction helpful.
-
George from Belhaven, NC
- Easy
- 30 - 60 mins
-
Nutdriver
Ordered new fan motor on line took out old motor and replaced with new one
Was this helpful?
Thank you for voting!
Motor noise while running and clicking when shutting off
1 of 2 people
found this instruction helpful.
-
Curtis from Sedona, AZ
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Was this helpful?
Thank you for voting!
Evap Fan Stopped Blowing..
1 of 2 people
found this instruction helpful.
-
James from Cave Creek, AZ
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
My fridge / freezer started getting very warm. But, the compressor and condenser fan were operating. I chose the defrost timer from the parts select suggested list. I took it apart and noticed the contacts were in bad shape. I validated this with my dvm meter. By checking continuity across the contacts while turning the timer knob.
... Read more
I also used my meter to check for 115 vac across the 2, 1 connections. . As you turn the timer knob, you'll hear a click. This should close the contacts and connections 4,3 should power up the evap fan. I also pulled the evap fan and powered it up on my test bench. I did this just to validate the timer was the problem. So, if you have a running compressor and condenser fan. Check the contacts on the defrost timer located under the front grill of your unit with a dvm. There is a small gear motor that runs the timer. Don't be fooled by the fact it's running. If the contacts are toast, replace the timer unit. Total time to fix the problem should be 15 mins. Tops.
Read less
Was this helpful?
Thank you for voting!
Light switch broke off
1 of 2 people
found this instruction helpful.
-
Kathy from TEMECULA, CA
- Very Easy
- Less than 15 mins
-
Pliers
We looked up the problem online with the model number of the refrigerator. We ordered the part and followed the video installation that was sent with the order and was found online prior to purchasing
Was this helpful?
Thank you for voting!
Rocker on switch broke off
1 of 2 people
found this instruction helpful.
-
David Barnes from ROSWELL, NM
- Very Easy
- Less than 15 mins
Eased the putty knife under the edge of the switch housing and pried it off. Pulled two wires off the old terminals and hooked them onto the new one and reinstalled into the refrigerator body.
Was this helpful?
Thank you for voting!
The fridge started leaking water and stop cooling!
1 of 2 people
found this instruction helpful.
-
Santos from Boca Raton, AL
- Easy
- Less than 15 mins
-
Nutdriver
I used the process of elimination. The freezer was cold but the fridge side was warm. The motor was runing but the fan was not working. I unplugged the power cord and pulled everything out of the freezer. Then I took the coil cover out. The unit was frozen solid. I used my wifes hair dryer to melt the ice on the coil and spray water with
... Read more
a bottle to speed up the process. It took about 15 minutes to melt the ice and plug the power cord again. The motor kicked on and the fan started blowing right away so I know it's not the fan. The following morning it was frozen again. I repeated the process of taking everything out and tested the heater element with a multimeter. It wasn't working allowing the ice to build over the coil so I replaced it. It took about 30 minutes to replace but two days later it froze again. I read a little to learn about the timer and the thermostat function in a refrigerator. The timer rotates to turn off the motor and turn on the heater element to melt the ice on the coil. I tried to rotate it but it felt too hard to turn and it smelled burnt out so I replaced it at once. It took me less than 10 minutes to replace. I also learn that the thermostat reaches certain temperature and activates the fan which blows the cold air out of the coil and throughout the fridge compartments. Because the coil and the thermostat were getting covered in ice, it was not activating the fan to blow the air out keeping the freezer side cold and the fridge side warm. By replacing them both, the thermostat and the timer I solved the problem. It took about 30 minutes to replace the thermostat but now it's working like a brand new one again.
Read less
Was this helpful?
Thank you for voting!
refrigerator stopped cooling due to condenser over-heating
1 of 2 people
found this instruction helpful.
-
Kevin from COVINGTON, LA
- Really Easy
- Less than 15 mins
-
Nutdriver, Pliers
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Was this helpful?
Thank you for voting!
light did not work on the refrigerator side
1 of 2 people
found this instruction helpful.
-
David from GROVESPRING, MO
- Easy
- Less than 15 mins
bulbs were not burnt out. received the new switch in a few days. watch the short video, was good to see how it comes out. used a putty knife to release the defective switch, removed wires put them on the new one and posed the new switch back in. Not bad Part cost $11.00 7 dollars shipping so for 17 bucks it works great. nice to see what i
... Read more
s inside the refer!
Read less
Was this helpful?
Thank you for voting!
Fridge contually cycles to defrost
1 of 3 people
found this instruction helpful.
-
andrew from oakland, NJ
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
With guidance from this web site, I was able to repair this myself very easily
Was this helpful?
Thank you for voting!
refrigerated stopped cooling, noticed that coils at bottom of freeezer were all iced over
1 of 3 people
found this instruction helpful.
-
Kurt from Cumming, GA
- Really Easy
- Less than 15 mins
-
Screw drivers, Socket set
Very easy repair. Remove 2 nuts that keep timer cover on regrigerater. Remove 2 screws that hold timer to cover, unplug wires from timer. Install new timer.
Was this helpful?
Thank you for voting!
The door gasket was very hot which is caused by an overheated expansion line that runs along the area of the door gasket. This was caused by a failed cooling fan motor.
2 of 6 people
found this instruction helpful.
-
James from Howell, MI
- Easy
- 30 - 60 mins
-
Nutdriver
Pulled out the refrigerator and removed the two panels from the rear of the refrigerator. Removed the fan held in by four screws and unplugged the connector. Soldered on the original connector, installed the fan to the motor and re-installed the unit into the refrigerator. Then blew out and vaccumed the condenser coils.
Was this helpful?
Thank you for voting!
Refrigerator would not stay cold
2 of 6 people
found this instruction helpful.
-
Jeremy from State College, PA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Wrench set
Removed rear cover to see non-operating fan - removed three mounting screws on the motor that were a challenge to access. Swapped fan from old motor onto new motor - one threaded nut on the motor shaft. Spliced new fan wires into fan wires of the wiring harness and mounted with three self-tapping screws supplied with new fan motor. Repl
... Read more
aced rear cover and plugged it in! Now the refrigerator cools like new (1981 model side-by-side Admiral)
Read less
Was this helpful?
Thank you for voting!
Refrigerator intermittantly thawing, not getting cold again.
1 of 3 people
found this instruction helpful.
-
ALexander from Chocowinity, NC
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Based on internet research, determined that the problem was likely the defrost timer or the thermostat that's clipped to the cooling coil behind the freezer. Once before, a repairman had replaced the thermostat only, so that was my first repair. Still not working right, so I replaced the timer as well, and everything's working. I opene
... Read more
d up the old timer switch and found the contacts were burned, partially arced.
If you have a similar problem, replace both parts. Only about $15 apiece
If you have a similar problem, replace both parts. Only about $15 apiece
Read less
Was this helpful?
Thank you for voting!
light staying on
0 of 1 people
found this instruction helpful.
-
Cecelia from Beaver Dam, WI
- Easy
- 15 - 30 mins
-
Screw drivers
A very cold and brittle switch in a 17 year old fridge. Used screwdrivers to pry out with some resistance Had to cut the molded plug in half and split wires, because replacement contacts were farther apart than the original. End result, works great.
Was this helpful?