Replace ice maker
21 of 28 people
found this instruction helpful.
-
Gary from Glendale, AZ
- Easy
- 15 - 30 mins
-
Screw drivers
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice b
... Read more
in had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Read less
Was this helpful?
Thank you for voting!
Ice maker would not make ice..
19 of 23 people
found this instruction helpful.
-
James from Mebane, NC
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmm ... Read more eter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmm ... Read more eter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Read less
Was this helpful?
Thank you for voting!
Filter needed to be replaced due to contamination
23 of 37 people
found this instruction helpful.
-
Alan from Southlake, TX
- Easy
- Less than 15 mins
The repair was quite easy. This is a Culligan unit installed by GE and we were supplied a number of filter elements when we purchased the house. We eventually used the supplied extras and had no idea what a problem getting replacements might be. Culligan at some point in time ceased to supply these filter elements and the GE replacement
... Read more
had to be installed with an adapter. There was no problem acquiring the adapter, the adapter seemed to be an unknown part to Lowe's and Home Depot personnel. The third Culligan employee I contacted was able to tell me what I needed and the GE part number.
Read less
Was this helpful?
Thank you for voting!
Stripper on the icemaker broke into pieces.
18 of 23 people
found this instruction helpful.
-
Tracy from Yuba City, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this helpful?
Thank you for voting!
Compressor overheating - Fridge not Cooling
16 of 19 people
found this instruction helpful.
-
CHRIS from LAGUNA NIGUEL, CA
- Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds
... Read more
the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Read less
Was this helpful?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
15 of 17 people
found this instruction helpful.
-
D from ZELLWOOD, FL
- Easy
- 15 - 30 mins
-
Screw drivers
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Was this helpful?
Thank you for voting!
ice maker not making ice
16 of 22 people
found this instruction helpful.
-
Cristina from Los Angeles, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Was this helpful?
Thank you for voting!
icemaker developed a leak and froze over
18 of 30 people
found this instruction helpful.
-
debbie from chino hills, CA
- Easy
- 15 - 30 mins
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Was this helpful?
Thank you for voting!
Ice maker ot making ice
18 of 31 people
found this instruction helpful.
-
Barry from Phoenix, AZ
- Easy
- 15 - 30 mins
-
Nutdriver
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
Was this helpful?
Thank you for voting!
Noisey Motor, Bearings Out, Dying
12 of 13 people
found this instruction helpful.
-
PERRY from VANDERBILT, MI
- Easy
- More than 2 hours
-
Nutdriver, Wrench set
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning whil
... Read more
e your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
Read less
Was this helpful?
Thank you for voting!
Flapper was stuck open. Old and warped.
16 of 27 people
found this instruction helpful.
-
James from Virginia Beach, VA
- Easy
- 15 - 30 mins
-
Screw drivers
Replaced flapper
Was this helpful?
Thank you for voting!
Interior light needed replaced
22 of 46 people
found this instruction helpful.
-
Leo from TWIN FALLS, ID
- Really Easy
- Less than 15 mins
-
Nutdriver
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Was this helpful?
Thank you for voting!
Defrost Thermostat quit working
11 of 13 people
found this instruction helpful.
-
Jimmy from Palmer, TN
- Really Easy
- Less than 15 mins
-
Screw drivers
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.
Was this helpful?
Thank you for voting!
Refridgerator Freezer stoped making ice
17 of 31 people
found this instruction helpful.
-
Marion from Palm Coast, FL
- Easy
- 30 - 60 mins
-
Screw drivers
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Si
... Read more
licone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
Read less
Was this helpful?
Thank you for voting!
fridge quit coolingg / freezing
11 of 13 people
found this instruction helpful.
-
JEFF from HAMPTON, GA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - rep
... Read more
laced cover - was hero with wife ... :-)
Read less
Was this helpful?
Thank you for voting!