Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
9 of 12 people
found this instruction helpful.
-
Tim from The Woodlands, TX
- Really Easy
- 15 - 30 mins
-
Screw drivers
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the o
... Read more
ld part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Read less
Was this helpful?
Thank you for voting!
Ice Maker wouldn't work, water tube freezing up, water leaking onto floor
10 of 15 people
found this instruction helpful.
-
Drew from Spring Lake, NJ
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench set
My problem was that the tube from the water valve to the ice maker was freezing when the valve was malfuntioning and sending more water, causing it to back up and freeze in the reception tube. Then the plastic water tube from the valve to the freezer seperated and water was leaking onto the floor. By reading the repair storyies on the Par
... Read more
tselect website I learned that the water valve was not working correctly and needed replacing. I ordered the replacement part on a Wednesday evening and had the part at my house via FEDEX on Saturday morning. It took me about 20 minuttes to complete the entire repair.
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
Read less
Was this helpful?
Thank you for voting!
Solenoid controlling the valve had stopped operating.
8 of 10 people
found this instruction helpful.
-
Eric from Rose Hill, KS
- Really Easy
- 15 - 30 mins
-
Screw drivers
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.
The valve was easy to change - took about 20 minutes total (including pu ... Read more lling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
The valve was easy to change - took about 20 minutes total (including pu ... Read more lling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
Read less
Was this helpful?
Thank you for voting!
no Ice
5 of 6 people
found this instruction helpful.
-
George from Brandywine, MD
- Easy
- 15 - 30 mins
-
Nutdriver
Turned off The water supply. Removed the back panel corner(nut driver). Removed valve (nut driver) and water supply inlet line. Cut the old outlet lines at the valve (new lines are push in) disconnected electrical lines, Reinstalled inlet line and electrical lines. Reinstalled valve and back panel. Turned on the water. Ice maker fi
... Read more
lled with water and a short time later I had ice. Easy job.
Read less
Was this helpful?
Thank you for voting!
The Ice Flapper warped and clogged up the Ice Shoot
5 of 6 people
found this instruction helpful.
-
Ronald from Elkridge, MD
- Really Easy
- 15 - 30 mins
-
Screw drivers
I bought a Flapper replacement part from Parts Select. I installed it following their very complete on-line video directions. Their complete and easy to follow directions made my job very easy, and the work was completed without any problems and just as good as if it were done by a professional repair person. I am proud of my work, it
... Read more
couldn't have been done without their video insructions. Also I got delivery of the part within two days of my order. I will alway look for Parts Select any time I need an applicance repaired. Thanks to Parts Select!
Read less
Was this helpful?
Thank you for voting!
Ice chute frosted up
6 of 9 people
found this instruction helpful.
-
Phillip from Springfield, VA
- Easy
- 30 - 60 mins
-
Screw drivers
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) ... Read more that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) ... Read more that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
Read less
Was this helpful?
Thank you for voting!
crushed ice feature inoperative, broken pieces in water dispensed.
6 of 9 people
found this instruction helpful.
-
Jim from Jacksonville, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
Found broken pieces of deflector in delivered ice. Removed dispenser, carefully disassembled it, marking fasteners, sprimgs, and levers. Local repaimen say no replacement part available, must replace entire ice maker @ $350. Found exact part in your online reference, ordered at price of $3.76, part arrived two days later--perfect fit, exa
... Read more
ctly same as original. Reassembled, and it works exactly like new. Family very happy. Good job!!!!!
Read less
Was this helpful?
Thank you for voting!
Tubing from vavle to reservoir had been degraded by compressor heat and had cracked, leaking water when door water dispenser was used.
6 of 10 people
found this instruction helpful.
-
Scot from Fort Collins, CO
- Difficult
- More than 2 hours
-
Nutdriver, Screw drivers, Wrench set
- Disconnect the valve assembly and remove electrical connection to water dispenser valve to prevent accidental water discharge
- Disconnect tubing from valve assembly, remove and keep compression nut.
-Disconnect tubing from junction to door tube remove and keep compression nut
-Remove screws used to moun ... Read more t reservoir, pull tubing into main refrigerator compartment and remove old reservoir and tubing.
- Note that one of the tubes on the new reservoir is 2' too short.
- Go to hardware store to purchase 5/16" universal tubing compression junction.
- Install reservoir and feed tubing through holes in main refrigerator compartment.
- Route tubing through woven tubing protectors and clips.
- Trim tubing to length and install in valve using old compression nut.
- Splice the piece of tubing trimmed from supply side of reservoir to the outlet side tube using the fitting purchased from the hardware store.
- Connect end of tubing to existing junction using old compression nut.
- Re-connect wires to valve solonoid and test for leaks.
- Re-install valve assembly to refrigerator frame.
- Disconnect tubing from valve assembly, remove and keep compression nut.
-Disconnect tubing from junction to door tube remove and keep compression nut
-Remove screws used to moun ... Read more t reservoir, pull tubing into main refrigerator compartment and remove old reservoir and tubing.
- Note that one of the tubes on the new reservoir is 2' too short.
- Go to hardware store to purchase 5/16" universal tubing compression junction.
- Install reservoir and feed tubing through holes in main refrigerator compartment.
- Route tubing through woven tubing protectors and clips.
- Trim tubing to length and install in valve using old compression nut.
- Splice the piece of tubing trimmed from supply side of reservoir to the outlet side tube using the fitting purchased from the hardware store.
- Connect end of tubing to existing junction using old compression nut.
- Re-connect wires to valve solonoid and test for leaks.
- Re-install valve assembly to refrigerator frame.
Read less
Was this helpful?
Thank you for voting!
Dispenser Water Reservoir failed seem
5 of 8 people
found this instruction helpful.
-
Scott from South Lake Tahoe, CA
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
This was a very easy fix. I cut the water lines at the reservoir, coupled the old lines to the new lines with two plastic barbed fittings used for outdoor drip irrigation. All I had to do was pull the old lines out and the new lines followed. Easy as pie!
Was this helpful?
Thank you for voting!
My wife called me at work and said the refrigerator was "peeing" on the floor.
3 of 3 people
found this instruction helpful.
-
Jerry from Hurst, TX
- Really Easy
- Less than 15 mins
-
Nutdriver, Pliers
When I got home I pulled the refrigerator away from the floor, checked all the water lines for leak evidence, and then took the back panel off to check everything behind. The water valve was leaking at the hose insert locations. I turned off the water, spent less than 5 minutes disassembling the valve from the rerfrigerator, and got onl
... Read more
ine to buy another one. The part arrived several days before expected, and it took me less time to install the new part than it did to take the old one out. Now all I have to do is repair the floor damage I caused when pulling out the refirgerator!
Read less
Was this helpful?
Thank you for voting!
Water was not running out of dispenser but the ice cube maker was working
4 of 6 people
found this instruction helpful.
-
Frank from Florham Park, NJ
- Easy
- 15 - 30 mins
-
Nutdriver, Wrench set
Well I Googled the problem to the dual inlet water valve. Luckily I found PartSelect for the correct part and the installation was simple. I now have both the cubes and water working properly from the dispense.
Was this helpful?
Thank you for voting!
Cold water dispencing was becoming slower and volume of ice was becoming less.
4 of 6 people
found this instruction helpful.
-
Peter from Ashford, CT
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers
Shut water supply off, removed power plug from wall and removed electrical connector from valve. Unscrewed two plastic nuts which retained lines to old valve. Remove old valve and reinstalled new valve with one screw. Removed inserts from end of lines. (These inserts keep lines from deforming.). Trimmed and chamfered ends of lines reinst
... Read more
alled inserts and installed lines to new valve. Turned on watter, checked for leaks turned power on inserted glass for water received good flow. Ice maker did not receive water. Due to low flow of water to ice tray because of low flow with old valve, ice built up in flexable water delivery tube that goes from back of refrigator to ice tray. Removed tube ran under warm water removed ice blockage reinstall tube all working excelent. This iceing problem took about anouther 15 to 25 min to correct.
Read less
Was this helpful?
Thank you for voting!
would not crush ice
3 of 3 people
found this instruction helpful.
-
Larry from Mount Airy, NC
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers
you must pay careful attention when taking the dispenser apart,especially the long rod that controls the deflector,but if close attention is payed to disassembly you should have no problem.
Was this helpful?
Thank you for voting!
The dispenser water reservoir had a pin hole leak.
3 of 5 people
found this instruction helpful.
-
Daniel from Genoa City, WI
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
1. Turned off the water supply to the refrigerator.
2. Removed the front panel and disconnected the water line to the front left.
3. Removed the left rear (freezer side) panel and disconnected the reservoir from the main water supply input. This was a little tricky to figure out. You must push in the water line at the same ti ... Read more me pushing in the coupling. Then pull the line out while keeping the coupling pressed in.
4. Removed the screw that holds the reservoir to the back of the refrigerator.
5. Pulled the old reservoir out and replaced it with the new one.
6. Basically the rest is the reverse of the above. It took a little bit to fish the lines through the original path they came.
Overall this was an easy repair. If I had known how the coupling in step 3 worked this would have been a 15-minute project.
2. Removed the front panel and disconnected the water line to the front left.
3. Removed the left rear (freezer side) panel and disconnected the reservoir from the main water supply input. This was a little tricky to figure out. You must push in the water line at the same ti ... Read more me pushing in the coupling. Then pull the line out while keeping the coupling pressed in.
4. Removed the screw that holds the reservoir to the back of the refrigerator.
5. Pulled the old reservoir out and replaced it with the new one.
6. Basically the rest is the reverse of the above. It took a little bit to fish the lines through the original path they came.
Overall this was an easy repair. If I had known how the coupling in step 3 worked this would have been a 15-minute project.
Read less
Was this helpful?
Thank you for voting!
heavy frost buildup in ice dispenser chute and door
2 of 2 people
found this instruction helpful.
-
Robert from Rockford, IL
- Really Easy
- 15 - 30 mins
-
Pliers
After inspection of the new door recess assembly, I realized that I could use sidecutters (electronic assembly type) and 'clip' off the inward lock tabs of the old recess assembly and disengage it from the crank door arm without any further disassembly of the refrigerator door. It was easy to 'unhitch' the tang from the crank arm and wi
... Read more
ggle it out through the external opening of the ice/water dispenser compartment. I reversed the process and inserted the new assembly through the external opening of the compartment. The new door recess assembly snapped into place on the crank arm and fit tightly against the ice chute opening, correcting the issue caused by aging distortion of the old rubber seal cup portion of the door recess assembly.
Read less