Switchlight was broken on tennant's refridge
10 of 12 people found this instruction helpful.
  • Mark from Somers Point, NJ
  • Easy
  • Less than 15 mins
  • Pliers, Screw drivers
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapp ed the new switch into place.

10 minutes total.
Was this helpful?
Thank you for voting!
broken ice maker
10 of 12 people found this instruction helpful.
  • robert from bensalem, PA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
Was this helpful?
Thank you for voting!
Valve was leaking at end-cap
19 of 39 people found this instruction helpful.
  • Thomas R. from Lexington, NC
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Socket set, Wrench (Adjustable)
Shut off water supply to refrigerator. Unplugged electrical supply. Removed waterline from valve and valve from refrigerator. Disconnected electrical connections to valve. Disconnected water supply from valve to refrigerator. Repeated the process in reverse order using the replacement valve. Checked water in refrigerator door for prop er operation and monitored area around valve for leaks before rolling refrigerator back into cabinet space.
Was this helpful?
Thank you for voting!
Leaking inlet water valve
10 of 13 people found this instruction helpful.
  • Gilbert from Tucker, GA
  • Easy
  • 15 - 30 mins
  • Wrench (Adjustable)
Disconect and Removed cover from back of frig.
Removed water supply pipe (adjustable wrench).
Removed Bracket and Valve Assembly from frig (1 screw).
Marked tube placements with marker so that I could put them back correctly.
Removed power connectors from valve.
Disconected tubes from valve (not that easy to pull off).
Connect tubes on new valve. Plug power connectors back in.
Screw the Assembly back on the frig.
Reconnect water supply & test for leaks.
Was this helpful?
Thank you for voting!
Will not make ice
13 of 23 people found this instruction helpful.
  • GEORGE from ELIOT, ME
  • Easy
  • Less than 15 mins
  • Screw drivers
Bing , Bang, Boom.
Was this helpful?
Thank you for voting!
Twice I ordered the oven light bulb & each time the light bulb was defected
18 of 38 people found this instruction helpful.
  • Barbara from BELLEVUE, WA
  • Very Difficult
  • Less than 15 mins
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appl iance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Was this helpful?
Thank you for voting!
Fridge not cold
9 of 11 people found this instruction helpful.
  • Christopher from Perkasie, PA
  • A Bit Difficult
  • More than 2 hours
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
On this fridge, you MUST take out the ice maker. First took out the shelves. Then take out the ice maker. This is done by taking out the four screws on the side that hold the assembly containing the bulb. Then there is one screw that holds that assembly to the icemaker. Do not take out any other screws, this is a mistake I made that cost me a few more hours figuring out how to get the other parts to mount correctly to the assembly containing the bulb. The icemaker should lift right out once the white plus is unplugged from the assembly that holds the light. Then took out the shelf brackets and finally could remove rear panel. Found it all iced up as others have. Took 1.5 hours to manually defrost while using sponges to sop up all the water that would run into the drain if you let it. Was about a gallon of water so using sponges worked well. Heater was open when checked with a meter, but you could tell it was blown by the way it looked. All cloudy. Put things back in reverse order. Had an issue with the icemaker shooting water out and missing the icemaker. Eventually was able to align better. This fridge had also just stopped dispensing water. I think the lines may have been frozen in the back, because one day after defrosting manually, the water dispenser started working again Overall this took about 4 hours. But a few days later, the water dispenser again stopped working. Not sure about that one. I have a valve already that I will try for this issue but somehow I don't think its the valve.
Was this helpful?
Thank you for voting!
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
9 of 12 people found this instruction helpful.
  • Tim from The Woodlands, TX
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the o ld part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Was this helpful?
Thank you for voting!
Water Leaking from behind refrigerator
13 of 25 people found this instruction helpful.
  • Greg from Eden prairie, MN
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
Turn off water to the refrigerator and unplug from wall outlet remove the defective inlet valve replace with new inlet valve. Now is a great to clean use a air compressor and vacuum and your old crusty frige will be good as new ! Special thanks to Parts Select fast shipping and original ge parts!!
Was this helpful?
Thank you for voting!
The eavporator coils were completely frozen which prevented fridge-freezer air circulation
7 of 7 people found this instruction helpful.
  • chris from GROVE CITY, OH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
1. Removed all food, shelves, and ice bin from freezer compartment.
2. Removed freezer light hood and unscrewed freezer bulb.
3. Removed rear evaporator cover panel (2 Phillip’s screws, 2 hex screws).
4. Melted ice on coils with hair blow dryer (needed bath towels to collected water).
5. Removed old defrost heater (2 P hillips screws, 2 plug-ins).
6. New heater connected without any adjustments.
7. Replaced evaporator cover ice bin, shelves and food.
Was this helpful?
Thank you for voting!
Quit dispensing and crushing ice.
9 of 13 people found this instruction helpful.
  • Charles from Odessa, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
Ordered new auger and ice bucket assembly. Removed old door and with four screws I attached it to the new unit. Works very well!
Was this helpful?
Thank you for voting!
leaked
8 of 11 people found this instruction helpful.
  • David from Tampa, FL
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
replaced water valve for 50 dollars, saved about 200 dollars by doing it myself
Was this helpful?
Thank you for voting!
No water/no ice
9 of 14 people found this instruction helpful.
  • Joseph from Cortlandt Manor, NY
  • Easy
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers
The first sign of trouble was when the water dispenser would continue to come out after you let up on the button. Then water and ice stopped. Changed the secondary inlet value and the main water valve, as well as a 1/4" water line running to the freezer (it was cracked). Water is working. Ice maker is working better than ever. New li fe for an aged refrige.
Was this helpful?
Thank you for voting!
Cams on Hinge assembly broken, door didn't close properly
7 of 9 people found this instruction helpful.
  • Stephen from Lafayette, NY
  • Really Easy
  • 15 - 30 mins
  • Socket set
I supported door with 2* 6 scrap wood. I used cedar shingles to raise door to correct height.
Using a socket wrench, I removed the hinge from the fridge and the cam assembly from the door.
I installed the new hinge and cam using the shims thatwere behind the original parts.
I removed the 2*6 supports and the door now works perfectly.
Was this helpful?
Thank you for voting!
Water inlet to icemaker freezes up.
8 of 12 people found this instruction helpful.
  • Nathan from Portage, MI
  • Easy
  • 15 - 30 mins
  • Screw drivers, Wrench (Adjustable)
Removed the back panel from the lower part of the fridge to expose the valves and motor. Then the one screw holding the valve/bracket assembly was removed to free the assy. It took a few minutes to figure out how to remove the water lines - popped the colored plastic rings out with a screwdriver and removed the lines. Inserted the line s one by one as they were removed to keep correct orientation. Removed the two electrical connections and plugged into new valve. Installed assy with the one screw. Replaced back panel.
Was this helpful?