Twice I ordered the oven light bulb & each time the light bulb was defected
18 of 38 people
found this instruction helpful.
-
Barbara from BELLEVUE, WA
- Very Difficult
- Less than 15 mins
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appl
... Read more
iance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Read less
Was this helpful?
Thank you for voting!
refrigerator did not cool
10 of 14 people
found this instruction helpful.
-
Carl from Kent City, MI
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
i put a new evaporator motor in and now it works fine
Was this helpful?
Thank you for voting!
Refridgerator was running constantly and condesor would get very hot, condesor fan would only turn on if I spun it.
8 of 9 people
found this instruction helpful.
-
Raymond from Los Lunas, NM
- Easy
- 15 - 30 mins
-
Nutdriver, Socket set
Unplugged fridge removed the three screws that held fan on to fan frame unplugged condensor fan removed brackets from old fan and put them on new fan installed new fan plugged in fridge and now it works great!
Was this helpful?
Thank you for voting!
Ice in freezer running down sides
8 of 9 people
found this instruction helpful.
-
P. Michael from Tustin, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
This is a built-in unit. Remove the external bezel at the top of the unit. Reach through the unit and unplug the frig. On the compressor unit, you'll see a vertical metal panel. Remove the metal panel and the timer is right behind it. Remove one wire at a time and switch it to the new timer. Remove timer and replace with new one.
... Read more />
Just an added comment, GE Service wanted to put an "ice kit" into my unit. The full repairs would have cost $1,000. While I described how to replace the defrost timer, the problem was the tray heater. But that's another story.
... Read more />
Just an added comment, GE Service wanted to put an "ice kit" into my unit. The full repairs would have cost $1,000. While I described how to replace the defrost timer, the problem was the tray heater. But that's another story.
Read less
Was this helpful?
Thank you for voting!
Noisy freezer evaporator fan, bearings worn out
8 of 10 people
found this instruction helpful.
-
Todd from Saint Paul, MN
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
UNPLUG UNIT. Open freezer compartment, top door. You may want to let it warm up a bit before beginning work. Next remove single screw from small square plastic grate at top left back of freezer compartment with phillips screw driver. Remove green ground wire connection behind removed grate with nut driver. Next remove 2 screws at top
... Read more
of freezer compartment holding plastic air diffuser bracket in place and holding back panel. Remove metal back panel of freezer by pulling top towards you, then angle out of compartment. Evap. fan is now exposed. I inspected and removed fan by removing two screws with nutdriver on bracket behind fan blade. I inserted nutdriver (with long socket driver)between fan blades to screws on bracket behind blade - 1 each side. After these two screws are removed, pull fan and bracket assembly out from plenum. Remove wiring from motor and remove motor to workbench. Remove round metal clamp from fan hub with needle nose pliers and slide off fan blade from motor. Also remove bracket and rubber bushing. Disgard old motor. Inspect and clean blade. Replace if necessary. Reattach rubber bushing, bracket THEN fan blade to new motor. New fan has atleast one terminal in new location and I had to use one wire extension that came with kit. Route wire behind motor and plug in new wires to back of motor. Insert fan and bracket to plenum, hold in place with one hand while reattaching screws with nutdriver between fan blades. Once fan is in place and nuts secure, I tested operation by plugging unit back in to make sure new motor ran and fan spun freely. Reattach back panel, top diffuser bracket and small grate with 3 screws. Shut door, set temp. and wait 24 hours before loading freezer. Unit good as new!
Read less
Was this helpful?
Thank you for voting!
defrost system kept freezing up
8 of 10 people
found this instruction helpful.
-
Robert from Williamstown, NY
- Easy
- 15 - 30 mins
-
Screw drivers
took out 4 screws - lowered timer cover - replaced timer- put it back together
Was this helpful?
Thank you for voting!
Refridgerator wouldn't cycle into defrost mode without doing it manually.
9 of 14 people
found this instruction helpful.
-
Ben from Warrior, AL
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set
I removed the shield over the timer and the part that supported the timer. Just unpluged it and pluged in new timer and put back shield. I had already replaced the defrost heaters which had totally burned up. I also replaced the thermostat while I was making the repairs although the old one was still o.k. All the information that I needed
... Read more
to make the repairs I obtained through your website. After looking at several websites to compare prices-etc, I found yours to be the best overall. Thanks-a-million your website is worth it's weight in Cold Food !
Read less
Was this helpful?
Thank you for voting!
stopped making ice
7 of 9 people
found this instruction helpful.
-
Timothy from Orange Park, FL
- Easy
- 15 - 30 mins
-
Nutdriver
First I turned off the water supply. Then I removed the ice bin and the ice maker by removing 4 screws and 3 electrical connections. This allowed access to the evaporator fan which was not moving. To remove the evap fan I removed two screws that hold the fan bracket. The fan assembly now had to be pushed back and rotated to remove fro
... Read more
m hole. There are 3 electrical connections that have to be disconnected from the fan, one ground wire that also is connected to the fan bracket and 2 power connections. Installing the new fan was the reverse of the above except the power connections were in a different location and i had to use the extension wires provided with the new fan to have the length needed to make the connection.
Read less
Was this helpful?
Thank you for voting!
refrigerator wasn't cooling but the freezer was working properly
6 of 6 people
found this instruction helpful.
-
Don from BELLVILLE, TX
- Very Easy
- 15 - 30 mins
-
Nutdriver
From instructions found on the site I was directed to the defrost timer part being bad. And from the information others posted that have had the same problem I was able to replace that part by removing the bottom grill just below the door and on the left side was the part. Removing one screw to remove the bracket from the frame and then
... Read more
another screw to remove the part from the bracket. I found it easier to remove the part from the bracket before I pulled the part out so I would have more room to unplug the connector. Just reverse the steps to replace the new part. It took about a day or so for the refrigerator to get to the proper temp.
Read less
Was this helpful?
Thank you for voting!
broken fan blade in the freezer compartment
7 of 9 people
found this instruction helpful.
-
John from Cumberland, MD
- Really Easy
- Less than 15 mins
-
Pliers
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
Was this helpful?
Thank you for voting!
Started to see a little sweat in freezer and ice cream not getting hard frig staying on longer.
6 of 7 people
found this instruction helpful.
-
Frank from Philadelphia, PA
- Easy
- 15 - 30 mins
-
Socket set, Wrench set
Pulled frig out. Removed back cover. Unplugged frig, unplugged motor. Removed fan from old motor first then 3 screws from bracket that holds motor and removed motor. Reattached motor back on bracket, reattached fan on motor. Plugged fan back in and then frig. Everything worked fine no more soupy ice cream !!
Was this helpful?
Thank you for voting!
Not cooling - cond fan did not turn
6 of 7 people
found this instruction helpful.
-
Daniel from Great Falls, VA
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers, Socket set
Unplug refrig! Removed back cardboard covering (~5 screws)
(1) Cleaned all the dust out (hardest part!)
(2) Removed power wire to motor
(3) Removed 3 bolts holding motor to frame
(4) Removed motor/fan blade to the left
(5) Moveded fan blade to new motor (clean it!)
(6) Replaced motor, reinstalled 3 bolts
... Read more >(7) Plugged power wire to new motor
(8) Tested it - worked fine, failed safe, drained to bilge!
Replaced back cover (had to tape it since I horked it up removing it)
(1) Cleaned all the dust out (hardest part!)
(2) Removed power wire to motor
(3) Removed 3 bolts holding motor to frame
(4) Removed motor/fan blade to the left
(5) Moveded fan blade to new motor (clean it!)
(6) Replaced motor, reinstalled 3 bolts
... Read more >(7) Plugged power wire to new motor
(8) Tested it - worked fine, failed safe, drained to bilge!
Replaced back cover (had to tape it since I horked it up removing it)
Read less
Was this helpful?
Thank you for voting!
light not working
7 of 11 people
found this instruction helpful.
-
robert from FRANKLIN SQ, NY
- Very Easy
- Less than 15 mins
-
Pliers, Screw drivers
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Was this helpful?
Thank you for voting!
unusually noisy
5 of 6 people
found this instruction helpful.
-
Anthony from South Plainfield, NJ
- Really Easy
- Less than 15 mins
-
Socket set
Removed the three screws from old motor body-bracket assembly , pulled off 1/4'' spade terminals and removed shield from terminal block for re-use.
Removed fan from old unit and installed on new,
screwed new motor in place, replaced terminal wires, plugged back in refrigerator.
Now my old rerfrigerator is whisper quiet
Removed fan from old unit and installed on new,
screwed new motor in place, replaced terminal wires, plugged back in refrigerator.
Now my old rerfrigerator is whisper quiet
Was this helpful?
Thank you for voting!
freezer cold but refrigerator warm, would not cycle the defrost on freezer
4 of 4 people
found this instruction helpful.
-
MATT from OAKLAND, MI
- Really Easy
- Less than 15 mins
-
Screw drivers
two screws and a connector were removed to replace the timer.