Would not heat and made a buzzing or popping sound
4 of 7 people found this instruction helpful.
  • Thomas from NEWARK, DE
  • Easy
  • 15 - 30 mins
  • Screw drivers
Unplug the microwave. Remove the Philips head and safety Torx head screws along the bottom of the sides and rear of the microwave which hold the black cover on. Lift the cover up at the rear and slide it backwards to disengage the tabs on the front top. Remove the cover. Discharge the capacitor by shorting the terminals to each other and then ground. Do this with a well insulated object and be aware there may be a pop when you do this. Keep hands, etc. on the insulated part of the object (screwdriver handle, etc). There's a lot of stored energy in that capacitor. I'd advise first checking the diode to make sure its not bad. Replace it if it is. The Magnatron is held in with a couple of screws on the top and sides. Unplug the connector and remove the screws. Remove the Magnatron. Installation is the reverse of removal.
Was this helpful?
Thank you for voting!
Frost build up on bottom to ice bin and delivery chute in door creating ice blockage
3 of 5 people found this instruction helpful.
  • Ronald from PONCA CITY, OK
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Remove the ice bin.
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of t he freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Was this helpful?
Thank you for voting!
Turntable motor was making noise
2 of 2 people found this instruction helpful.
  • Allan from LOUISVILLE, KY
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Unscrewed and dropped the bottom panel of the Advantium on its rear hinge, disconnected the light and the motor, removed the motor screws, and replaced the motor. Very simple.
However, not related to the Advantium or the motor, trim had been applied to the bottom of the wall cabinets after installation of the Advantium. This trim pr evented the lowering of the panel (and future removal of the whole oven), so I had to chisel and file and repaint the trim to get it out of the way.
Was this helpful?
Thank you for voting!
Microwave not turning on. All other functions operate
2 of 2 people found this instruction helpful.
  • Tom from DENVER, CO
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
DISCONNECT THE POWER CORD and discharge the capacitor
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switc hes (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
Was this helpful?
Thank you for voting!
Bad door switch and divide
3 of 6 people found this instruction helpful.
  • Robert from COLORADO SPGS, CO
  • Easy
  • 30 - 60 mins
  • Screw drivers
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry up. Removing grnd wires helps
Was this helpful?
Thank you for voting!
the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
2 of 3 people found this instruction helpful.
  • James C from ARLINGTON, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent openi ng to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
Was this helpful?
Thank you for voting!
Door Switch went bad, Internal Fan would run every time you open the door
1 person found this instruction helpful.
  • gilbert from TOMS RIVER, NJ
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
Was this helpful?
Thank you for voting!
Microwave would not heat up
1 person found this instruction helpful.
  • Suzanne from POWELL, OH
  • Really Easy
  • 15 - 30 mins
Part just snapped into place and wires were reattached.
Was this helpful?
Thank you for voting!
Not heat
1 person found this instruction helpful.
  • Kip from POWELL, OH
  • Very Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Was this helpful?
Thank you for voting!
Microwave would not heat. Convection still worked.
1 person found this instruction helpful.
  • Stacie from Granbury, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I verified I had 120 volts going into transformer when the microwave was supposed to be running. The capacitor and HV diode both tested good. Be sure to discharge the capacitor before working in this area. This isolated trouble to either the transformer or magnetron. The windings of the transformer measured good. So ordered a magnetron. I t was very easy to swap. There were 4 screws and one connector. This fixed our microwave.
Was this helpful?
Thank you for voting!
Unit would not heat
1 person found this instruction helpful.
  • william from LA VERNE, CA
  • Easy
  • 30 - 60 mins
  • Pliers, Socket set, Wrench (Adjustable)
Used a Motor cycle Jack to remove both unites combined. Removed side panels exposing internal working parts. Removed nonworking Magnetron and replaced it with new Magnetron. The process was completed in about 1 hour.
Was this helpful?
Thank you for voting!
Microwave wouldn’t heat
1 person found this instruction helpful.
  • Rex from ROSEVILLE, CA
  • Really Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
I want to preface this review by stating that I do some DIY from YouTube, but have no experience in electronic repair. The microwave is over the stove with the extendavent. First I unplugged the microwave, removed the vent and started to unscrew the microwave from the mount. I used a power drill to speed things up. I was able to remove the microwave on my own. I unscrewed the lid on the microwave and took the lid off and there is the magnetron. I opened up needle nose pliers to have each end touch the terminals of the capacitor (holds the power, Dangerous). I made sure to keep my hands on the rubber handles and avoid touching the metal part of the pliers. I used the pliers to remove the plug of the capacitor to the magnetron as well. The magnetron has 4 screws (2 top, 2 bottom). There is a magnet that can hold the screws to keep from falling but I’d still recommend a screwdriver with a magnet on the end. The magnetron has another set of wires connected by a metal bracket like a holder, not really connecting any wiring to the magnetron itself. I had to unscrew 1 screw to removed that. Adding everything back on was easy, same steps back. I plugged in the microwave and tested a cup of water before I mounted it back above the stove. Voila! I did need my wife’s help to hold the microwave on the hinge while screwing into the mount. It doesn’t take a lot of muscle for the help. $85 for the part and ~40 mins to fix a $400 microwave!
Was this helpful?
Thank you for voting!
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
1 person found this instruction helpful.
  • Pearlie from Beulaville, NC
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followe d them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
Was this helpful?
Thank you for voting!
M/W would not start. control panel OK
1 person found this instruction helpful.
  • Jeffrey from FULSHEAR, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers
unplugged power
removed main black cover.
located part WB24X10047 and replaced
Was this helpful?
Thank you for voting!
no power in microwave in turn table wouldn't turn light would work act like door was open
5 of 13 people found this instruction helpful.
  • johnny from port orange, FL
  • Easy
  • 1- 2 hours
  • Screw drivers
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
Was this helpful?