Lawn mower would not start
2 of 4 people
found this instruction helpful.
-
Lorraine from MIDDLETOWN, NY
- Very Easy
- Less than 15 mins
-
Screw drivers
removed cover over motor blew it out of leaves and dust. Removes 4 screws and removed piece ordered. The coil was rusted and not connecting. Changed oiece its working again
Was this helpful?
Thank you for voting!
door latch broken
1 person
found this instruction helpful.
-
Loretta from PRT JEFFERSON, NY
- Very Easy
- Less than 15 mins
removed broken latch connected to existing spring done in less than two minutes works better than new
Was this helpful?
Thank you for voting!
Light bulb went out
1 person
found this instruction helpful.
-
Judith A from LAKEWOOD, CO
- Very Easy
- Less than 15 mins
-
Screw drivers
Opened the light cover. Removed the old light bulb using a light tug on the old bulb, lined up the new bulb and pushed gently into the socket.
Turned the power back on and the microwave is good to go.
Turned the power back on and the microwave is good to go.
Was this helpful?
Thank you for voting!
burned wave guide cover
1 person
found this instruction helpful.
-
Edward from ANTIOCH, IL
- Very Easy
- Less than 15 mins
-
Screw drivers
remove with phillips screwdriver. insert 3 corners in to slots and insert and tighten screw.
Was this helpful?
Thank you for voting!
Door Switch went bad, Internal Fan would run every time you open the door
1 person
found this instruction helpful.
-
gilbert from TOMS RIVER, NJ
- Really Easy
- 15 - 30 mins
-
Screw drivers
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
Was this helpful?
Thank you for voting!
Microwave would not heat up
1 person
found this instruction helpful.
-
Suzanne from POWELL, OH
- Really Easy
- 15 - 30 mins
Part just snapped into place and wires were reattached.
Was this helpful?
Thank you for voting!
Not heat
1 person
found this instruction helpful.
-
Kip from POWELL, OH
- Very Easy
- 15 - 30 mins
-
Screw drivers, Socket set
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Was this helpful?
Thank you for voting!
M/W would not start. control panel OK
1 person
found this instruction helpful.
-
Jeffrey from FULSHEAR, TX
- A Bit Difficult
- 30 - 60 mins
-
Pliers, Screw drivers
unplugged power
removed main black cover.
located part WB24X10047 and replaced
removed main black cover.
located part WB24X10047 and replaced
Was this helpful?
Thank you for voting!
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
1 person
found this instruction helpful.
-
Pearlie from Beulaville, NC
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followe
... Read more
d them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
Read less
Was this helpful?
Thank you for voting!
Unit would not heat
1 person
found this instruction helpful.
-
william from LA VERNE, CA
- Easy
- 30 - 60 mins
-
Pliers, Socket set, Wrench (Adjustable)
Used a Motor cycle Jack to remove both unites combined. Removed side panels exposing internal working parts. Removed nonworking Magnetron and replaced it with new Magnetron. The process was completed in about 1 hour.
Was this helpful?
Thank you for voting!
broken latch
1 person
found this instruction helpful.
-
Wilson from Pembroke Pines, FL
- Easy
- 30 - 60 mins
-
Screw drivers
We used the scresdriver(flat) to remove the frame inside the door, the remove several screws retaining the inner part of the door thenremoved the broken piece. We replaced the latch with the spring With a little patience, everything went fine. I broke one of the small tab, no big deal.
thanks, you saved me a lot of money/.
thanks, you saved me a lot of money/.
Was this helpful?
Thank you for voting!
Microwave wouldn’t heat
1 person
found this instruction helpful.
-
Rex from ROSEVILLE, CA
- Really Easy
- 30 - 60 mins
-
Pliers, Screw drivers
I want to preface this review by stating that I do some DIY from YouTube, but have no experience in electronic repair. The microwave is over the stove with the extendavent. First I unplugged the microwave, removed the vent and started to unscrew the microwave from the mount. I used a power drill to speed things up. I was able to remove
... Read more
the microwave on my own. I unscrewed the lid on the microwave and took the lid off and there is the magnetron. I opened up needle nose pliers to have each end touch the terminals of the capacitor (holds the power, Dangerous). I made sure to keep my hands on the rubber handles and avoid touching the metal part of the pliers. I used the pliers to remove the plug of the capacitor to the magnetron as well. The magnetron has 4 screws (2 top, 2 bottom). There is a magnet that can hold the screws to keep from falling but I’d still recommend a screwdriver with a magnet on the end. The magnetron has another set of wires connected by a metal bracket like a holder, not really connecting any wiring to the magnetron itself. I had to unscrew 1 screw to removed that. Adding everything back on was easy, same steps back. I plugged in the microwave and tested a cup of water before I mounted it back above the stove. Voila! I did need my wife’s help to hold the microwave on the hinge while screwing into the mount. It doesn’t take a lot of muscle for the help. $85 for the part and ~40 mins to fix a $400 microwave!
Read less
Was this helpful?
Thank you for voting!
Turntable Stopped Working/Display Timer Would Countdown But Not Heat
1 person
found this instruction helpful.
-
Steve from Wesley Chapel, FL
- Really Easy
- 30 - 60 mins
-
Screw drivers
With this model, you must remove the outer covering. Don't try to access the display unit from the front like I've seen in some other GE microwave videos. After removing the outer covering, the switches are easy to replace. They are very visible and easy to get to without taking any other parts off. You will see the door switches just
... Read more
behind the display board. Remove the switch and then remove the connecting wires to ensure you don't inadvertently brake a wire. You will need a tamper resistant star bit to remove 3 or 4 screws from the back panel. All other screws are philips head. I went ahead and replaced both switches (yes...there are two of them) and works like a charm. I saved an $800 microwave for less than $60 and know what to do if it happens again. Appears to be a common problem on this model. Thanks for others making a post...It saved me time and money reading others remarks. Good luck!
Read less
Was this helpful?
Thank you for voting!
no power in microwave in turn table wouldn't turn light would work act like door was open
5 of 13 people
found this instruction helpful.
-
johnny from port orange, FL
- Easy
- 1- 2 hours
-
Screw drivers
remov cover to check voltage and found problem at the interlock switch ohm the switch and found it was open replace both switches it work fine now
Was this helpful?
Thank you for voting!
The unit would run when the door was open!
1 person
found this instruction helpful.
-
Mike from BLUFFTON, SC
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
Was this helpful?
Thank you for voting!