the evaporator fan stopped working
8 of 11 people found this instruction helpful.
  • Stephen from Bloomfield, NJ
  • Easy
  • 15 - 30 mins
  • Screw drivers
I removed the plastic cowl in the rear of the freezer to gain access to the fan, took out two screws that secured the brackets holding the fan. Then I separated the coupling wires which had a sort of locking mechanism that was simple to undue. I took out the brackets along with the fan, separated the brackets and removed the screw for the ground wire. Then I simply reversed the process.
Was this helpful?
Thank you for voting!
Oven light bulb went dark; it needed replacing
10 of 17 people found this instruction helpful.
  • Lise from CEDAR GROVE, NJ
  • Very Easy
  • Less than 15 mins
Twisted replacement bulb into place easily. Let there be light!
Was this helpful?
Thank you for voting!
Thought the evaporator fan was the issue
7 of 8 people found this instruction helpful.
  • Dale from Fort Myers, FL
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
Did the obvious. Removed the stick-out cover, then the back of the freezer wall, after taking the bad evaporator fan out. Replaced the old motor with the new one, stuck the fan blades back on, and put the replacement back in place. Checked to see that the new motor and fan, before final hook up, had no issues. That was a success. How ever, when I put the parts in place, I had some significant vibrations. By taking things apart and re-doing the install, the vibrations went away. However, the final install, even if quiet, did not work. Apparently the condenser was kaput. No cooling after all the adjustments. We gave up and are replacing the fridge.
Was this helpful?
Thank you for voting!
fan motor worn out
7 of 9 people found this instruction helpful.
  • Richard from Norman, OK
  • A Bit Difficult
  • 15 - 30 mins
  • Screw drivers
Removed the old and installed the new. Electrical plug/socket made connection easy. Biggest problem is working space in freezer side of a side by side with the fan in the back. If I can do it anyone can.
Was this helpful?
Thank you for voting!
replaced door seal
6 of 7 people found this instruction helpful.
  • Doug from Jonesville, MI
  • Easy
  • 15 - 30 mins
  • Nutdriver
followed documentation from Frigidaire website.
Was this helpful?
Thank you for voting!
Freezer frosted up
6 of 7 people found this instruction helpful.
  • Gregg from Mohnton, PA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Wrench set
Removed old thermostat and replaced. really easy.
Was this helpful?
Thank you for voting!
Coils freezing up and refrigerator would get warm
6 of 7 people found this instruction helpful.
  • Richard from Scranton, KS
  • Easy
  • 15 - 30 mins
  • Nutdriver
Wasn't sure if it was the derost timer or the heating element. Since the timer was much cheaper, I bought it and crossed my fingers.
My story is like the others. Unplug the refrigerator, snip the old wires, strip back the wire insulation, use the supplied connectors to attach the new defrost timer to the existing wiring.
Succe ss! My coils no longer freeze up.
Only difficulty is I am a large guy, and fitting my upper body into the freezer was challenging.
Was this helpful?
Thank you for voting!
Freezer was getting a build up of frost on the condenser and wasn't cooling.
5 of 5 people found this instruction helpful.
  • Arthur from Lithonia, GA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
Was this helpful?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
5 of 5 people found this instruction helpful.
  • Bruce from MARTINEZ, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.

After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.

I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.

I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Was this helpful?
Thank you for voting!
Refrigerator Light bulb went out
7 of 12 people found this instruction helpful.
  • ANGELA from MEBANE, NC
  • Very Easy
  • Less than 15 mins
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
Was this helpful?
Thank you for voting!
freezer would not defrost
5 of 6 people found this instruction helpful.
  • Fernando from La Grange, AL
  • Easy
  • 30 - 60 mins
  • Screw drivers, Wrench set
tested defrost timer and heater. And then tested defrost timer with ohm test($6 at hard ware store) Closed and would not open replace and tested freezer take 30mins to get switch cold and retest.
Was this helpful?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people found this instruction helpful.
  • gary from ARANSAS PASS, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Was this helpful?
Thank you for voting!
the evaporator fan quit when we had a power surge
5 of 7 people found this instruction helpful.
  • Darrell from Bentley, ND
  • Easy
  • 15 - 30 mins
  • Screw drivers
A screw driver was used to remove two screws that held the old fan in place the new fan ws installed exactly where the old one came out and presto the job was complete. No major deal.
Was this helpful?
Thank you for voting!
Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
4 of 4 people found this instruction helpful.
  • David from ABINGDON, VA
  • Easy
  • 15 - 30 mins
  • Screw drivers
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the cop per refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
Was this helpful?
Thank you for voting!
Repaired Oven Range Light Bulb
3 of 3 people found this instruction helpful.
  • Alan from SAN MATEO, CA
  • Very Easy
  • Less than 15 mins
  • Screw drivers
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.