End Cap on refrigerator handle broke
20 of 26 people found this instruction helpful.
  • Stephanie from Tucson, AZ
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I unscrewed the top broken end cap and bottom end cap (had to match-up the chrome pieces), attached the handle to both of the new end caps, and using a phillips screw driver, screwed them back on to the refrigerator. Very easy.
The blow-up illustration I used to order the part, it was very helpful.
Was this helpful?
Thank you for voting!
Orig Ice maker died
18 of 21 people found this instruction helpful.
  • Al from Frankfort, IL
  • Easy
  • 15 - 30 mins
  • Nutdriver, Wrench (Adjustable)
I was able to salvage the existing wiring and simply replace the ice maker itself and the valve located at the bottom-rear of the frig.

Simply removed and replaced the screws, changed the water tube and connected everything back up. I probably spent more time cleaning behind the frig that replacing the parts.

Very p leased with how quickly the parts came and everything was included!
Was this helpful?
Thank you for voting!
compressor didnt turn on
24 of 41 people found this instruction helpful.
  • gerardo from el monte, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
changed the starter connected to the compressor
Was this helpful?
Thank you for voting!
freezer making a squealing sound
17 of 20 people found this instruction helpful.
  • PAUL from Boiling Springs, SC
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
First I Removed the racks. Next 3 hex bolts that secured the ice maker. Undid the ponytail wiring. 3 Phillips screws to remove the metal back. unplugged the Evaporator Fan Motor. Replaced the new one. reassembled.
Was this helpful?
Thank you for voting!
Squealing evaporator fan
15 of 18 people found this instruction helpful.
  • JOHN from BEAVER, PA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Unplugged the fridge, emptied the freezer, removed the panel screws, removed the fan assembly retaining nuts, slid the spade wire connectors from the tabs, and performed these tasks in reverse to have the fridge up and running like new. I am not an appliance repair person, but I am not intimidated by simple repairs. Your instructions wer e easy to follow, and the cry in the kitchen of "we need a new refrigerator" was silenced for less than $50.00. Thanks!
Was this helpful?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
14 of 16 people found this instruction helpful.
  • David from Cedarville, OH
  • A Bit Difficult
  • More than 2 hours
  • Screw drivers, Socket set
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Was this helpful?
Thank you for voting!
Was not making ice and the filler tray was chipping material.
16 of 24 people found this instruction helpful.
  • Robert from Hummelstown, PA
  • Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
With a socket set and screw driver I removed the old ic e maker . It took about 1 hr. I worked slowly as not to make a mistake. The only part that gave me a problem was the plug. You need to take off the face cover to press down on the plastic release clip. Putting it back took half the time because you knew what to look for.Just plug it in and mount the screws back in place , make sure it was level and I had ice in about an hour.
Was this helpful?
Thank you for voting!
Old door handle bent in a move--Missing
14 of 18 people found this instruction helpful.
  • Nicholas from Indianapolis, IN
  • Easy
  • Less than 15 mins
  • Screw drivers
First of all, I looked at the blow apart diagrams on Part Select website. That made it really easy to determine the parts I needed to complete the repair. Once I had received the parts and verified that all had arrived in good order, it took me 5 minutes and a Phillips screwdriver to do the rest.
Was this helpful?
Thank you for voting!
Freezer compartment iced over, food thawing,
12 of 13 people found this instruction helpful.
  • Lawrence from New Bern, NC
  • Easy
  • Less than 15 mins
  • Nutdriver
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back porti on to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
Was this helpful?
Thank you for voting!
water was leaking down from freezer section to bottom part of unit
13 of 16 people found this instruction helpful.
  • Eric from miami, FL
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me a ccess to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
Was this helpful?
Thank you for voting!
Scratches in Surface
83 of 227 people found this instruction helpful.
  • Michelle from Richardson, TX
  • Really Easy
  • Less than 15 mins
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.
Was this helpful?
Thank you for voting!
Broken gooseneck on fill tube
10 of 11 people found this instruction helpful.
  • Thomas from Brunswick, OH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
The gooseneck on the icemaker fill tube extends out beyond the back cabinet of the refrigerator, and is easily broken. Luckily, this part is a piece of cake to replace. You'll literally spend more time pulling out your fridge and cleaning out behind it then you will replacing this part.

Shut off water supply line, and turn of f ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.

Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people found this instruction helpful.
  • martin l. from JACKSONVILLE,, IL
  • Really Easy
  • Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people found this instruction helpful.
  • Steven from Brigham City, UT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people found this instruction helpful.
  • Benjamin from Daytona Beach, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot al time of ice maker water leak repair and fan replacement about 1 hour.