Evaporator frozen (refrigrator section) and allowing top section to lose cooling
110 of 184 people
found this instruction helpful.
-
Richard from GULFPORT, MS
- Easy
- 30 - 60 mins
-
Screw drivers
This is the Samsung French door refrigerator style that so many people have complained about freezing up and not cooling the top section. I first changed out the defrost thermostat and this did not correct the problem. I done a quick resistance check on the temp sensor that's mounted on the evaporator itself. The resistance would change w
... Read more
hen holding an ice cube on the sensor so I just assumed it was ok. PLEASE TAKE NOTE: When performing a resistance check on this sensor, make sure your readings match the Samsung temp/resistance chart in their literature. My sensor was way off calibration and was causing the freeze up. Its working as designed now and DW is happy again. Learn from my mistake.
Read less
Was this helpful?
Thank you for voting!
Water filter needed to be changed.
25 of 57 people
found this instruction helpful.
-
Arlena from CHICAGO, IL
- Very Easy
- Less than 15 mins
-
Pliers
unlock filter with pliers with a turn to the right, pull out and replace filter, Turner new filter to the left until it click in.
Was this helpful?
Thank you for voting!
Ice Build up behind refrigerator internal panel
5 of 7 people
found this instruction helpful.
-
David from WILMINGTON, DE
- Really Easy
- More than 2 hours
-
Pliers, Screw drivers
I performed the repair to my own refrigerator, after watching multiple YouTube videos. I installed a secondary heater for the defrost coils and replaced the defrost sensor. The defrost sensor was actually bad. Today, 1/27/2024 I rechecked the fix from last week. All seems to be good so far.
If I get any build up of any ice on t ... Read more he bottom tray of the recessed panel where the drain port is located. I suspect I will also need a new Defrost Heater as well. For now the refrigerator is operating as expected. There is a small amount of ice build up as of today.
Also, I had recently replaced the drain tubes, added a longer heater element part to fit the drain hole, and cleaned the fins in the back of the refrigerator. Thank you.
If I get any build up of any ice on t ... Read more he bottom tray of the recessed panel where the drain port is located. I suspect I will also need a new Defrost Heater as well. For now the refrigerator is operating as expected. There is a small amount of ice build up as of today.
Also, I had recently replaced the drain tubes, added a longer heater element part to fit the drain hole, and cleaned the fins in the back of the refrigerator. Thank you.
Read less
Was this helpful?
Thank you for voting!
Fridge side no longer cooled, freezer still workekd fine.
3 of 5 people
found this instruction helpful.
-
Roger from Belle Fourche, SD
- Easy
- 1- 2 hours
-
Screw drivers
A couple of blogs said the freezer defrost sensor should be replaced, so I ordered one. Did not fix it. I did, however find a service manual online and one of the blog sites and it showed me how to remove the inside duct work. I discovered the fan the recirculates the air across the evaporator coil was not working. Ordered a new fan mo
... Read more
tor and installed it, fridge works perfectly now.
Read less
Was this helpful?
Thank you for voting!
ice dispenser screw cracked
3 of 5 people
found this instruction helpful.
-
Ira from MANHATTAN BCH, CA
- Really Easy
- Less than 15 mins
replaced ice "bucket"..snapped out old one, snapped in new
Was this helpful?
Thank you for voting!
Water inlet valve on ice maker failed to close allowing water to continue to flow
1 person
found this instruction helpful.
-
Merlin from GREEN BAY, WI
- Easy
- 30 - 60 mins
-
Screw drivers
It took me a while to figure out that the water and ice maker inlet valves are part of the water filter case assembly. That allowed me to determine which part to order. The part came as promised.
I was able to reuse the water inlet line from the old assembly by disconnecting the one from the new assembly. I wasn't able to re ... Read more move the water and ice maker outlet valves from the new unit. That meant that I needed to tape a piece of string to the old lines that penetrate the bottom of the refrigerator cabinet. Then I disconnected the electrical connections and pulled the unit out. Taped the string to the new water supply lines and pulled them through the cabinet opening to the front of the cabinet. Reconnected lines to the lines at the door. The screw hole that connects the assembly to the side of the cabinet didn't quite match up with the original unit this meant I had to do some minor adjustment.
After installing, I left the ice maker off at the door panel and bled the water line to remove any air in the line. The next step should have been obvious but, it wasn't to me. You need to turn the ice maker on at the door panel, reset the ice maker (blue button) and, allow it to run through several cycles to refill (prime), the water line to the ice maker. This can take a couple of hours as it acts as though it receives a full 95CC of water each time it cycles. By that I mean it releases 95CC of water, waits for it to freeze and then goes through the motion of dumping cubes into the bin. It can take several cycles just to fill the water line in the door.
I was able to reuse the water inlet line from the old assembly by disconnecting the one from the new assembly. I wasn't able to re ... Read more move the water and ice maker outlet valves from the new unit. That meant that I needed to tape a piece of string to the old lines that penetrate the bottom of the refrigerator cabinet. Then I disconnected the electrical connections and pulled the unit out. Taped the string to the new water supply lines and pulled them through the cabinet opening to the front of the cabinet. Reconnected lines to the lines at the door. The screw hole that connects the assembly to the side of the cabinet didn't quite match up with the original unit this meant I had to do some minor adjustment.
After installing, I left the ice maker off at the door panel and bled the water line to remove any air in the line. The next step should have been obvious but, it wasn't to me. You need to turn the ice maker on at the door panel, reset the ice maker (blue button) and, allow it to run through several cycles to refill (prime), the water line to the ice maker. This can take a couple of hours as it acts as though it receives a full 95CC of water each time it cycles. By that I mean it releases 95CC of water, waits for it to freeze and then goes through the motion of dumping cubes into the bin. It can take several cycles just to fill the water line in the door.
Read less
Was this helpful?
Thank you for voting!
Refrigerator was too cold - down to 18 degrees Fahrenheit.
5 of 14 people
found this instruction helpful.
-
Bill from RALEIGH, NC
- Really Easy
- 30 - 60 mins
-
Screw drivers
Removed shelves. Removed back cover. Removed old sensor. Installed new sensor. Replaced back cover. Replaced shelves. Works fine.
Was this helpful?
Thank you for voting!
Refrigerator Temperature Blinking
0 of 3 people
found this instruction helpful.
-
Christopher from Queen Creek, AZ
- Easy
- 1- 2 hours
-
Screw drivers
I removed all of the internal shelves from the refrigerator side. I then removed the cooling panels from the bottom area. this exposed the fan assembly and cooler. I found ice all over the unit. I had to unplug the refrigerator and used a hair dryer to melt the ice away. I then found the sensor and replace it. After putting the refrigerat
... Read more
or back together, I plugged it in and let it cool overnight. I also put a thermometer to validate that cooling was stable. it has been a week with the new sensor and the refrigerator has not frozen over and has been very stable.
Read less
Was this helpful?
Thank you for voting!
Refrigerator side wasn't cooling properly. Was staying at 55 degrees.
4 of 17 people
found this instruction helpful.
-
Robert from Simi Valley, CA
- A Bit Difficult
- 1- 2 hours
-
Pliers, Screw drivers
Took off the plastic panel in the interior. As usual, the evaporator was completely iced up. Took most of the time to de-ice it with a heat gun. Tested the components and the temperature sensor was bad which is on the top end of the evaporator fins. The ohms test wasn't any different whether hot or cold. I keep a spare sensor on hand beca
... Read more
use this is the third time one of the sensors have failed. The proper readings are available by doing some internet searching. Its been two weeks since I worked on it and everything is working fine.
Read less
Was this helpful?
Thank you for voting!
Freezer Door would not stay closed
8 of 30 people
found this instruction helpful.
-
Adriana from EDINBURG, TX
- Easy
- 30 - 60 mins
-
Screw drivers, Wrench (Adjustable)
Unplug electrical harness Took down freezer door , disconnected water lines, took out broken pieces and install new part and replaced door
Was this helpful?
Thank you for voting!
We misplaced the mounting screws for our handles while moving.
5 of 21 people
found this instruction helpful.
-
Sara from BAKERS MILLS, NY
- Very Easy
- Less than 15 mins
It was easy! I just used an alan wrench to losen the side bolt, then slid the handle into the new mounting screws that I had hand-screwed and then tightened it all up.
Was this helpful?