Fridge got warm and freezer coils were frosted
340 of 407 people
found this instruction helpful.
-
Stephen from Warrington, PA
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
Fridge is a side by side. The freezer is pretty narrow for a guy with wide shoulders.
Pulled plug.
Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be re ... Read more moved.
Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.
Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.
Removed old badly corroded thermostat.
I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.
Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.
Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.
Plugged back in and everying is working great!
Pulled plug.
Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be re ... Read more moved.
Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.
Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.
Removed old badly corroded thermostat.
I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.
Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.
Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.
Plugged back in and everying is working great!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Side-by-side .. freezer working, fridge not cooling
48 of 52 people
found this instruction helpful.
-
Tad from Lancaster, OH
- Easy
- 15 - 30 mins
-
Screw drivers
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc
... Read more
. After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
Read less
Was this helpful?
Thank you for voting!
no cooling in fridge or freezer due to bad defrost timer
29 of 37 people
found this instruction helpful.
-
Todd from pottstown, PA
- Easy
- Less than 15 mins
-
Screw drivers
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.
Was this helpful?
Thank you for voting!
The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.
24 of 27 people
found this instruction helpful.
-
Erle from Boise, ID
- Easy
- 15 - 30 mins
-
Screw drivers
First, unplug the refrigerator since you're working with live wires.
Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the re ... Read more frigerator during the defrost cycle.
Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.
Attach the new defrost timer to the plastic housing with the 2 screws.
Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.
Plug the refrigerator back in and you're done.
Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the re ... Read more frigerator during the defrost cycle.
Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.
Attach the new defrost timer to the plastic housing with the 2 screws.
Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.
Plug the refrigerator back in and you're done.
Read less
Was this helpful?
Thank you for voting!
Fridge warming but freezer still frozen
24 of 30 people
found this instruction helpful.
-
Todd from Thornton, CO
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I ordered a defrost timer and defrost thermostat from partselect.com. Parts arrived in 2 days (earlier than expected). Unplugged appliance, removed bottom cover, unscrewed 2 screws holding timer in place, unplugged timer and replaced with new part. Fastened back into place. Next removed back cover of freezer (5 screws using nut driver
... Read more
). Disconnected old thermostat and removed. Wires already had connectors installed. cut off the connectors with some wire left on and reconnected them to the new thermostat with the included blue wire crimps. Tried to use the shrink tube to insulate but couldn't get it snug enough. Just used electrical tape instead. Reinstalled thermostat. Reassembled cover. Plugged in and fridge and freezer are working fine again. Thanks partselect.com.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Refrigerator freezing
22 of 30 people
found this instruction helpful.
-
Miles from Longview, TX
- Easy
- 15 - 30 mins
-
Screw drivers
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.
Was this helpful?
Thank you for voting!
Fridge side warm. Freezer was ok.
13 of 15 people
found this instruction helpful.
-
Doug from Folsom, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
Popped off the front plastic cover on the bottom of the fridge, under the doors. Two screws held the defrost timer on under the front side of fridge (below freezer door). You can't really see the timer except for the adjustment knob that is accessible through a hole. Once the screws are removed, disconnect the wire plug and remove and re
... Read more
placed unit. Works fine ever since.
Read less
Was this helpful?
Thank you for voting!
wonnt defrost
15 of 23 people
found this instruction helpful.
-
bruce from grand haven, MI
- Really Easy
- 15 - 30 mins
-
Nutdriver
removed back cover from freezer to replace defrost stat. removed cover from refrigerator to replace defrost timer
Other Parts Used:
Was this helpful?
Thank you for voting!
freezer kept icing over, refrigerator too hot
11 of 13 people
found this instruction helpful.
-
debra from new washington, OH
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers
First, I unplugged the appliance. Safety, first.
Than I removed the shield which was held in by screws. This covered the fan, thermometer.
The defrost thermostat was taken out, with a little extra force. The wires on the defective part were no longer attached to the part. The instructions were easy to follow in replacing the d ... Read more efrost thermostat. I stripped the coating on the wire, attached it with the enclosed electical bugs. The assy was able to follow, and the part went back on. The refrigerator is working perfectly. I couldn't have done it without the help in diagnosing the problem and with the speedy delivery of the new part. Thanks for all your help and the ease of the installing the new part!
Than I removed the shield which was held in by screws. This covered the fan, thermometer.
The defrost thermostat was taken out, with a little extra force. The wires on the defective part were no longer attached to the part. The instructions were easy to follow in replacing the d ... Read more efrost thermostat. I stripped the coating on the wire, attached it with the enclosed electical bugs. The assy was able to follow, and the part went back on. The refrigerator is working perfectly. I couldn't have done it without the help in diagnosing the problem and with the speedy delivery of the new part. Thanks for all your help and the ease of the installing the new part!
Read less
Was this helpful?
Thank you for voting!
Freezer Won't Auto Defrost
13 of 20 people
found this instruction helpful.
-
Ricky from San Francisco, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Make sure unplugged the frig before doing any repair. Just like other DIYers. opened up the evaporator located inside the freezer. Replaced the defrost thermostat, there's only 2 wires, so just make sure which is positive, which is negative. Replaced the defrost timer located on the bottom front of the frig. There's on 2 screws to unscre
... Read more
w. All those work took me less than half hour. Turn on the frig., now it works like a champ again. Hope it will last another 10 years.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
The fridge motor was running constantly and the fridge was warm inside
9 of 10 people
found this instruction helpful.
-
James from Brighton, TN
- Really Easy
- 30 - 60 mins
-
Screw drivers
I secured the power to the fridge. I took the metal panel which covers the cooling coils in the freezer off by removing the the 6 sheet metal screws. I used a standard hair dryer to melt the ice block which had formed due to the failure of the defrost timer. I replace the defrost timer, which was located behind the left front wheel of
... Read more
the unit. Finding the timer was the hardest part of the job. Since I was having trouble with the defrost cycle I also decided to replace the defrost thermostat due to its age. The most important item I would like to share is once all the work is done and the panel is back in the freezer, the power is restored take a straight slot screw driver and give the defrost timer about an eighth of a turn clockwise to ensure it starts. Then mark it with a sharpe and check it in 3 or 4 hours to make sure it is running. I did not do this on the one I installed and the freezer did not go into the defrost cycle. Once I got the timer started, well the ice cream stay frozen. BE SURE NOT TO WORK ON YOUR EQUIPMENT WITH IT PLUGGED INTO POWER SOURCE!!!
Jim
Jim
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Erratic light.
9 of 11 people
found this instruction helpful.
-
D KIRKE from CORVALLIS, OR
- Really Easy
- Less than 15 mins
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement s
... Read more
witch.
Read less
Was this helpful?
Thank you for voting!
freezer and refrigerator too warm
9 of 13 people
found this instruction helpful.
-
Joel from Sunny Isles Beach, FL
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers
I put the refrigerator and saw that the fan wasn't working so I change the fan and the problem still the same. I order a timer and thermostat and change them, nothing change so I order the capacitor and when I remove it I saw that the relay swith was burn out so I order a switch and evarything is ok.
The problem when the fan broke th ... Read more e compressor overheat and burn the swich.
I learn a lot and still saving money over these repair guy.
Thanks
The problem when the fan broke th ... Read more e compressor overheat and burn the swich.
I learn a lot and still saving money over these repair guy.
Thanks
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Oven light bulb went dark; it needed replacing
10 of 17 people
found this instruction helpful.
-
Lise from CEDAR GROVE, NJ
- Very Easy
- Less than 15 mins
Twisted replacement bulb into place easily. Let there be light!
Was this helpful?
Thank you for voting!
Freezer frosted up
6 of 7 people
found this instruction helpful.
-
Gregg from Mohnton, PA
- Really Easy
- 15 - 30 mins
-
Screw drivers, Wrench set
Removed old thermostat and replaced. really easy.
Was this helpful?