Refigerator Not Staying Cold
5 of 5 people found this instruction helpful.
  • Marsha from BEVERLY, MA
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Wrench set
Bought the defrost timer based on PartSelect recommendations, installed it and no change. Apparently the old one was fine but since the refrigerator was in a flood and this part got submerged in water I kept it rather than returning it. I looked at everything closely and realized all the mechanical functions were working properly. Rarely does a condenser coil fail so I decided to look into recharging the coolant. Bought a 1/4 inch bullet valve, a 12oz. can of R-134a and a cheap resealable can adapter with hose, gauge and R22 to R-134a adapters. After a $30. investment Bingo, after one squirt the refrigerator began to cool and after 4oz. it now works better than new. I understand that PartSelect is in the business of selling only their parts but please consider that there can be other simple problems.
Was this helpful?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
5 of 5 people found this instruction helpful.
  • Bruce from MARTINEZ, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.

After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.

I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.

I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Was this helpful?
Thank you for voting!
Freezer was running too warm
6 of 8 people found this instruction helpful.
  • Jeanne from SAN ANTONIO, TX
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Removed the old defrost timer by removing 4 screws on the holding bracket. Disconnected the wire harness. Reconnected the wire harness to the new part. Installed the new part with 2 screws on the top of the molded bracket. I am a 67 year old woman... easy-peasy. (the defost timer is located in the bottom left rear of the freezer.
Was this helpful?
Thank you for voting!
Freezer would not run ... replace the compressor start relay which fixed the problem
4 of 4 people found this instruction helpful.
  • Tom from CEDARTOWN, GA
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Pulled out the freezer. Unplugged. No freezer back cover was there. The compressor start relay was in a plastic encasement attached to the compressor - wires led me to it. Removed the solid metal spring with a screwdriver and removed the plastic cover. Tried to pull out the defective relay but the freezer was so old I needed a pliers to r emove it. When I put pressure on the old relay with the pliers the relay broke and came off in pieces. I then removed the wires from the broken parts and put them on the new relay. I pushed the new relay onto the 2 pins then replaced the cover and spring. After plugging the freezer in the problem was fixed.
Was this helpful?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
5 of 7 people found this instruction helpful.
  • gary from ARANSAS PASS, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Was this helpful?
Thank you for voting!
Pushbutton light switch failed.
4 of 5 people found this instruction helpful.
  • Arlee from HOUSTON, TX
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
Needed a Phillips head screwdriver to remove bottom plate (kick panel). UNPLUGGED FREEZER. Removed plate pulled switch out through the mounting hole and unhooked the two electric wires. Plac ed wires on new switch, pushed wires back through the hole and seated the switch. Plugged in the freezer and opened the door - magic, the light came on. Replaced the front kick panel (hardest part was to line up the plate holes with the holes in the mounting bracket).
Was this helpful?
Thank you for voting!
Defrost Timer
4 of 6 people found this instruction helpful.
  • DAVE from LOS RANCHOS, NM
  • Very Easy
  • Less than 15 mins
  • Screw drivers
The old defrost timer started making a screeching noise (probably bearings going out). The replacement part was a cinch to install. When I initially spoke to a PartsSelect person, they said the part number I gave them was not consistent with my old '94 Tappan Freezer. They were able to still find the proper replacement part number. Th e video that was on-line helpful also.
Was this helpful?
Thank you for voting!
freezer would frost up and not get cold enough to keep frozen.
3 of 3 people found this instruction helpful.
  • Richard from SLIDELL, LA
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
Removed shelves ,removed panel on interior back wall with Philips screwdriver ,unplugged wire terminals slid thermostat off coil ,then reversed process to complete installation.
Was this helpful?
Thank you for voting!
Freezer wouldn't shut off and wouldn't reach cold enough temperature.
3 of 3 people found this instruction helpful.
  • Tunis from NOLANVILLE, TX
  • Easy
  • 15 - 30 mins
  • Screw drivers
Removed existing part, tested it, found it to be defective. OrderEd a new one and replaced the existing one.
Was this helpful?
Thank you for voting!
bad gasket seal
3 of 3 people found this instruction helpful.
  • Jason from WHITEWATER, WI
  • Very Easy
  • 30 - 60 mins
  • Screw drivers
removed old one and replaced with new
Was this helpful?
Thank you for voting!
No problems
2 of 2 people found this instruction helpful.
  • Steve from PRAIRIEVILLE, LA
  • Really Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
It went exactly like your on line video. It took longer to defrost the freeze than it did to make the parts change out.
Was this helpful?
Thank you for voting!
Freezer not cooling due to icing up of coil.
2 of 2 people found this instruction helpful.
  • Thomas from GRANBURY, TX
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Was this helpful?
Thank you for voting!
Freezer was not freezing.
2 of 2 people found this instruction helpful.
  • Andre from ANDERSON, SC
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
I removed the compressor start relay and replaced it with the new part. Initially it did not work. When I checked my work, I had to tighten the connector on the new part. Once I made the correction, the freezer is freezing normally again.
Was this helpful?
Thank you for voting!
I knockedoff the door light sensor when I dropped a frozen jug of ice
2 of 2 people found this instruction helpful.
  • Rob from HILLSBORO, NH
  • Very Easy
  • 15 - 30 mins
  • Screw drivers
I removed the plate (recommend using a magnetic phillips head screw driver to remmove screws which are recessed). I removed the old part and pushed the new part through the hole and carefully reached in behindto attach the wires to the new part.
Was this helpful?
Thank you for voting!
Cooling coils would ice up and fridge would warm up
2 of 3 people found this instruction helpful.
  • Richard from Tehachapi, CA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I removed the shelves in the freezer, took out the five 1/4" screws and lifted off the cover. It was a simple matter of using a blow drier to remove all the ice, then unplugging the two wires and unclipping the thermostat from the upper cooling tube. Then clipped the new one on and reconnecting the two wires.

Works great!!!
Was this helpful?
Thank you for voting!
All Instructions for the R22CW7